Chapter
5
Commissioning
Important:
These procedures
must
be carried out for the initial start-up of a
new
system. Failure to follow these
instructions can lead to System and component damage.
Check the Installation
Verify that the System has been installed properly, based on the checkpoints below. In addition, complete the
New
System Initial Readings Form
on page 96 and retain it with your Owner's Manual.
Remember:
Damage caused to the system due to operation of an improperly installed system is the liability
of the Installer and the Operator, and is not covered by the Sea Recovery Corporation warranty.
• Check each water connection to the System to ensure that the Installer has properly connected and routed each
tube. Improper routing and/or line blockage will cause System damage. Improperly connected and/or loosely
connected lines that result in leaks and/or damage are the liability of the Installer and the Operator, and are not
covered by the Sea Recovery Corporation warranty.
• Do not assume and do not rely on the Installer’s word; check the System installation yourself.
• Ensure that the Electrical Power Source and the ship's System circuit breaker is switched
OFF
position.
• Open the Electrical Control Box and verify all electrical and electronic connections. Check for proper wiring and
attachment. After checking all wiring for proper attachment, close the Electrical Control Box.
• Switch the Electrical Power Source and the ship’s System circuit breaker to the
ON
position.
Check RO Membrane(s)
Important:
At times, Sea Recovery Corporation will ship an Aqua Matic XL
WITHOUT
an RO Membrane
Element installed. This is for the purpose of accommodating ship builders who want to install the System in
advance of commissioning the ship.
Verify that the RO Membrane Element(s) have been installed properly within the Pressure Vessels. If the RO
Membrane Element has been installed, there will be an RO Membrane Element Serial Number tag attached to the
High Pressure Vessel. If the RO Membrane Element Serial Number tag is missing or does not contain a serial
number and date, then immediately contact the company that sold the System to you, the Installer, or Sea Recovery
Corporation.
Caution:
DO NOT attempt to operate the System without an RO Membrane Element installed, otherwise
extensive damage
will result. Damage caused to the System due to an incorrectly installed RO Membrane
Element(s) is the liability of the Installer and the Operator, and is not covered by the Sea Recovery Corporation
warranty.
System Valve Positions
Note:
The Inlet Thru-Hull Sea Cock Valve is in the
OPEN
position. It is recommended (for ship safety) that
you close the Sea Cock Valve whenever the System is not in use. This will protect the ship from flooding,
should a hose or component fail.
39
Содержание Aqua Matic XL Compact Modular Series
Страница 2: ......
Страница 10: ......
Страница 28: ......
Страница 38: ......
Страница 44: ...Aqua Matic XL 2200 3600 44...
Страница 45: ...45...
Страница 46: ...Aqua Matic XL 2200 3600 46...
Страница 63: ...63 Commissioning...
Страница 64: ......
Страница 76: ......
Страница 94: ......
Страница 97: ...97...
Страница 98: ......
Страница 116: ......
Страница 119: ...Chapter 10 Appendix 119...
Страница 123: ...ABS Certificate of Design Assessment 123...
Страница 124: ...FCC Compliance Appendix Aqua Matic XL 2200 3600 124...
Страница 125: ...Single Phase Electrical Motor Wiring 125 Appendix...
Страница 126: ...Three Phase Electrical Motor Wiring Aqua Matic XL 2200 3600 126...
Страница 127: ...Three Phase Transformer Wiring 127 Appendix...
Страница 128: ...New System Initial Readings Form Aqua Matic XL 2200 3600 128...
Страница 129: ...Daily System Readings 129 Appendix...
Страница 130: ......
Страница 131: ...Chapter 11 Exploded Parts Views 131...
Страница 132: ...Exploded Parts View Aqua Matic XL 2200 3600 132...
Страница 134: ...8 11 12 18 21 24 25 26 1 2 3 4 5 Exploded Parts View 134...
Страница 139: ...6 10 14 10 6 10 4 10 13 8 14 10 6 5 7 7 5 11 12 3 2 3 3 2 3 10 4 7 9 7 1 4 139...
Страница 143: ...11 4 12 2 11 1 5 16 14 20 3 15 13 9 17 18 19 7 10 6 8 143...
Страница 146: ...2 8 11 10 7 1 5 3 12 9 18 13 14 14 16 15 17 16 14 19 15 17 4 6 Exploded Parts View 146...
Страница 148: ...11 9 12 10 5 4 6 1 8 22 3 2 21 16 20 14 19 16 17 15 7 15 13 23 24 Aqua Matic XL 2200 3600 148...
Страница 150: ...10 26 11 9 5 5 4 20 1 7 18 3 2 16 13 15 12 14 13 23 24 21 24 25 Exploded Parts View 150...
Страница 152: ...12 10 13 11 5 5 4 6 1 9 20 3 2 17 16 14 18 15 19 17 16 14 18 15 8 7 Exploded Parts View 152...
Страница 159: ...6 1 16 14 12 9 11 12 13 12 5 4 2 15 3 15 7 8 10 159...
Страница 162: ...14 19 21 12 8 6 9 20 12 3 4 7 1 18 10 10 23 7 26 17 5 16 24 25 24 25 17 13 11 2 15 22 Exploded Parts View 162...
Страница 166: ...6 7 2 3 2 5 10 10 12 1 11 8 9 8 11 6 7 4 2 13 14 Aqua Matic XL 2200 3600 166...
Страница 169: ...6 15 7 13 18 11 16 27 25 26 21 1 4 3 2 3 12 19 9 17 14 23 8 20 9 19 5 27 16 24 22 10 169...
Страница 177: ...Chapter 12 Electric Diagrams Foldouts 177...
Страница 178: ...Aqua Matic XL Series Three Phase Wiring Diagram...
Страница 179: ...179...
Страница 180: ......
Страница 183: ......
Страница 184: ...Sea Recovery 2630 E El Presidio Street Carson CA 90810 sales searecovery com www searecovery com PN B6513100001...