Sea Recovery Aqua Matic XL Compact Modular Series Скачать руководство пользователя страница 1

Aqua Matic XL Compact/Modular 2200-3400

Owner’s Manual

SYSTEM MODELS

   

SRC Aqua Matic 2200 
SRC Aqua Matic 2600 
SRC Aqua Matic 2800
SRC Aqua Matic 3400 

 
 

Manual PN 

  B6513100001

        |   

Revision 

3

/7/201

8

Содержание Aqua Matic XL Compact Modular Series

Страница 1: ...Aqua Matic XL Compact Modular 2200 3400 Owner s Manual SYSTEM MODELS SRC Aqua Matic 2200 SRC Aqua Matic 2600 SRC Aqua Matic 2800 SRC Aqua Matic 3400 Manual PN B6513100001 Revision 3 7 2018...

Страница 2: ......

Страница 3: ...Recovery SRC MCC 3 Membrane Cleaning Chemical 16 Patent Information 16 Chapter 2 System Description 17 Pre Installation Safety Checks 17 Storage Prior to Uncrating 17 Chemical Precautions 17 System Sa...

Страница 4: ...39 System Valve Positions 39 Controller Setup 40 Manual System Check 61 Multi Media Filter Backwash and Rinse 62 Chapter 6 General Operation 65 Important Notes 65 New Systems 65 Freezing Temperature...

Страница 5: ...Connector 87 Multi Media Filter Waste and Brine Discharge Tee 87 Thru Hull Discharge Fitting 87 Product Water T Collector 87 Salinity Probe 88 3 way Product Water Diversion Solenoid Valve 88 Charcoal...

Страница 6: ...WATER SEPARATOR 32 5 SQFT AQMXL AQMDP 141 A300C AQUA MATIC XL COMPACT 142 A310M AQUA MATIC XL MODULAR 144 B156300008 HP GP PUMP MOTOR 7 6GPM 5HP 200V 60Hz 1PH ASSY EXPLODED 145 B156300006 HP GP PUMP M...

Страница 7: ...y on are typically correctable Note that if a minor component problem is left uncorrected it can affect the rest of the system and lead to more extensive issues and or damage Important Sea Recovery en...

Страница 8: ...e laws and regulations pertaining to the use of this manual In addition the use of this manual forms an agreement that Sea Recovery s trademarked name or Sea Recovery s trademarked logo mark are not t...

Страница 9: ...the content within this manual is strictly prohibited Copyright Sea Recovery Corporation 2008 2012 Revision History Description Affected Pages Date Rev Initial Release of the 2008 DX Models 0 ix Abou...

Страница 10: ......

Страница 11: ...operator With one touch the Aqua Matic XL will start and finish water production automatically Inside this manual you will find detailed technical information and instructions for the installation op...

Страница 12: ...nventory for immediate shipment and our Service Dealers throughout the world maintain stock of Sea Recovery parts Always insist on Sea Recovery supplied parts in order to avoid failures eliminate prob...

Страница 13: ...tation or labor expenses incurred in removing and returning the product to the service center or to Sea Recovery Corporation Registration Sea Recovery Corporation recommends that all customers registe...

Страница 14: ...environmental regulations Compliance Sea Recovery s Reverse Osmosis Desalination Systems are Type Accepted by the American Bureau of Shipping ABS Sea Recovery s Reverse Osmosis Desalination Systems co...

Страница 15: ...SICIAN DO NOT INDUCE VOMITING GIVE ONE GLASS OF TAP WATER OR MILK IN CASE OF CONTACT IMMEDIATELY FLUSH EYES WITH WATER FOR 15 MINUTES GET IMMEDIATE MEDICAL ATTENTION THOROUGHLY WASH AFFECTED SKIN AFTE...

Страница 16: ...IATELY FLUSH EYES WITH WATER FOR 15 MINUTES GET IMMEDIATE MEDICAL ATTENTION THOROUGHLY WASH AFFECTED SKIN AFTER HANDLING PRODUCT CONTACT A PHYSICIAN IF IRRITATION PERSISTS MEDICAL PERSONNEL FAMILIAR W...

Страница 17: ...XL that may contain any of the following chemicals Hydrogen peroxide chloramines T Chlorine dioxide chlorine Bromine phenolic disinfectants Chloramines N chlorioisocyanurates Hypochlorite iodine Brom...

Страница 18: ...ount the liquid holding component above any electrical or electronic device Extensive damage to the electronic device will result if liquid enters device during maintenance and or component failure Im...

Страница 19: ...water temperature Product water temperature Automatic computer controlled electronic monitoring The salinity monitoring components of the system give a continuous readout in micromhos per cubic centim...

Страница 20: ...in a position that provides a continuous air free supply of Feed Water Important The Aqua Matic XL must receive an uninterrupted supply of Feed Water without air The Aqua Matic XL must not be tied in...

Страница 21: ...ry configurations In addition diagrams depicting several pre filtration configurations have been provided Please follow the steps below when installing your System 1 Determine pre filtration and post...

Страница 22: ...y non Sea Recovery components spares and assemblies will result in the following Damage to the Aqua Matic XL and or damage to specific components within the System Voiding the Aqua Matic XL s warranty...

Страница 23: ...aintenance labor and pre filter element replacement cost For additional information on obtaining this optional accessory please contact Sea Recovery Corporation 9 Commercial Pre filter optional Takes...

Страница 24: ...Membrane Element and Vessel will double the System s production 5 High Pressure Hose RO Membrane Element and Vessel Assembly Outlet to High Pressure Manifold Inlet 6 High Pressure Transducer Measures...

Страница 25: ...lves calcium carbonate into the Product Water thus bringing the pH level back to neutral i e at approximately pH 7 Note The pH value of pure water is pH 7 which is regarded as neutral pH values from 0...

Страница 26: ...on singular individual plates or together on a double plate The Rinse Clean Inlet Valve used in conjunction with the Rinse Clean Outlet Valve simplifies the storage and cleaning procedures by allowing...

Страница 27: ...l Logic that shuts off the System automatically Fresh Water Tank High Level Switch when the Fresh Water Tank is full Note System has to be operating in Automatic mode Additionally the System will not...

Страница 28: ......

Страница 29: ...w ease of detachment and re attachment for maintenance and or replacement If electrical cables are pulled tight and bent at the strain relief then they may detach from the strain relief The result is...

Страница 30: ...grams within this manual Motor Rotation Refer to Booster Pump and High Pressure Pump markings to determine proper rotation For three phase systems you may ensure proper rotation by jogging each motor...

Страница 31: ...heet metal screws are provided for attachment 1 Lay the System frame on a flat surface and mark the mounting holes 2 Temporarily move the System frame and drill the appropriate holes depending on the...

Страница 32: ...pressure pick up points to the Low Pressure Transducers Use of this tubing is dependent upon the optional Pre filtration components installed in your System Important If the RO Membrane Element and Pr...

Страница 33: ...re in a location that meets the following criteria Away from water lines and hoses Away from locations that could be sprayed with water In an accessible and viewable location Within 80 ft 24 4 m of th...

Страница 34: ...ce with the following conditions parameters Install the unit in a sheltered well ventilated area Install the unit as close as possible to the point of use in order to avoid potential contamination dis...

Страница 35: ...e Place the closed end of the quartz sleeve into the cylinder through the ballast box pass thru Leave in 12 7 mm of the quartz sleeve to expose on the viewport pass thru 6 Lubricate the tips of the qu...

Страница 36: ...cylinder with water while checking for leaks 6 If leaks are found on the compression nuts depressurize the unit and slightly tighten the leaking compression nut 7 Retest until a leak free installation...

Страница 37: ...ons are met when mounting operating the unit Release the pressure in the UV treatment chamber before breaking the compression nut seals Disconnect all power to the UV unit before servicing Do not allo...

Страница 38: ......

Страница 39: ...r wiring and attachment After checking all wiring for proper attachment close the Electrical Control Box Switch the Electrical Power Source and the ship s System circuit breaker to the ON position Che...

Страница 40: ...p The controller is set by Sea Recovery Corporation prior to shipping based on the ordered System features and optional equipment The addition of the Fresh Water Flush to the System after it has shipp...

Страница 41: ...Million PPM The factory setting is 800 PPM Total Dissolved Solids TDS expressed as NaCl i e Sodium Chloride or salt d Manually control the System pressure by increasing or decreasing the back point pr...

Страница 42: ...tomatic back washing by adjusting the number of days 5 Language Change the current controller language by selecting new language option 6 Unit Toggle the measurement standards between U S Standard and...

Страница 43: ...ure U S Standard PSI Pounds Per square Inch Metric Standard kPa kilo Pasquel b Flow U S Standard GPM Gallons Per Minute or GPH Gallons Per Hour Metric Standard LPM Liters Per Minute or LPH Liters Per...

Страница 44: ...Aqua Matic XL 2200 3600 44...

Страница 45: ...45...

Страница 46: ...Aqua Matic XL 2200 3600 46...

Страница 47: ...our system should not be running when attempting to enter dealer commissioning mode CAUTION All electrical covers should be on before providing powering to the system Electrical shock may accrue if el...

Страница 48: ...ct or Enter in SYSTEM TYPE SYSTEM FREQUENCY SYSTEM SIZE and CURRENT TIME Aqua Matic Aqua Whisper DX Aqua Matic XL SYSTEM SIZE RANGE 450 1800 450 1800 2200 3400 SYSTEM FREQUENCY 50 or 60 Hz 50 or 60 Hz...

Страница 49: ...your system System Tank Level Control ON OFF System UV Sterilizer ON OFF System Fresh Water Flush ON OFF System Emergency Stop ON OFF Communications Status ON OFF Communications Protocol STD NMEA 200...

Страница 50: ...TRY TO RUN SYSTEM COMPONENT FOR LONG PERIODS OR DAMAGE WILL ACCURE 12 Press each tab to test Power and or motor rotation Auxiliary Pump On Off Booster Pump On Off High Pressure Pump On Off Product Va...

Страница 51: ...System Health screen displayed by the controller is shown below 14 Press Save Exit Your system is now configured Display Settings The Aquamatic Aquamatic XL and AquaWhisper desalination system control...

Страница 52: ...Press Brightness to set desired brightness level To return to the Main Menu screen simply press on the Home button as shown above Press here Press here Press here Press here and slide left or right P...

Страница 53: ...ime format 4 Press on Set Time enter in the correct time 5 Press Set for 2 seconds to set time 6 Press home to return Press here to select 12 or 24hr format Press here Press here Enter the correct tim...

Страница 54: ...Run Timers 1 Press system settings icon 2 Press Run Time 3 Press HP Pump Delay to change default setting for the HP pump time delay Press here Press here Startup Setting Area Press here Aqua Matic XL...

Страница 55: ...controls the delay period applied to the state change of the production tank level switches As the tank begins to fill with fresh water and with movement of the vessel the water level within the tank...

Страница 56: ...equals the value stated Production range is from 1 gallon to 4000 gallons 6 activate this feature Auto Shutdown Operation This controls the amount of time the water maker will operate Once the operat...

Страница 57: ...on of the fresh water flush 7 Press Fresh Water Flush Frequency to change the default number of days between fresh water flushing 8 Press Fresh Water Flush Cycle Duration to change the default time fo...

Страница 58: ...g a value 1 Press system settings icon 2 Press Salinity tab 3 Move slider bar left or right to adjust salinity or enter desired value in required Product Quality The Salinity value range is 150PPM to...

Страница 59: ...Frequency This controls the sleep time between system fresh water flush cycles Immediately after a system shutdown the fresh water flush program activates for a set duration This flushing is done to...

Страница 60: ...tion range is from 3 minutes to 30 minutes 8 Press Fresh Water Flush Cycle Duration to change the default time for fresh water flushing Current Fresh Water Flush Status NOTE This display variable indi...

Страница 61: ...fine mesh screen filter element c Multi Media Filter if installed Check for media 20 silica sand d Dual Pre filter or Commercial Pre filter Check for pleated cartridge filter elements e Oil water Sepa...

Страница 62: ...er Check for illumination from the UV Sterilizer viewport 7 Prime the System To save time and make the initial System start easier fill the feed water lines and each component in the Pre filtration se...

Страница 63: ...63 Commissioning...

Страница 64: ......

Страница 65: ...grade Glycerin Propylene Glycol RO Membrane Element Warning Caution Never store the RO Membrane Element or Membrane Vessel Assembly in direct sunlight Never expose the RO Membrane Element or Membrane...

Страница 66: ...SI maximum 414 kPa is exceeded then the System will shut down and revert to a fault mode due to excess pressure In this event the Owner or Installer must install a Pressure Reduction Valve from the sh...

Страница 67: ...el screen adjust the salinity to desired level 188 to 370 PPM then touch the SETUP button 4 On the next screen touch the Manual Mode button 5 On the next screen touch the Booster Pump START button the...

Страница 68: ...d Flow Operating Pressure Brine Flow Product Flow and Product Salinity are all being monitored and the values of these readings cause the System Control Logic to perform various tasks to maintain prop...

Страница 69: ...e The Automated Fresh Water Flush Cycle will not be performed until the System is operated in the Automatic Mode The Automated Fresh Water Flush will NOT activate automatically because operation durin...

Страница 70: ...lve then position this valve to draw from the Rinse Clean Bucket or Container 2 Configure the Brine Discharge line for a Closed Loop Configuration as shown in the figure on the next page Disconnect th...

Страница 71: ...Water Rinse i e a rinse with fresh Product Water from the System The Fresh Water Rinse prolongs System and RO Membrane Element life by minimizing electrolysis and arresting biological growth If your...

Страница 72: ...ntaining the RO Membrane Element s high flux and salt rejection properties If the System will be shut down for over four 4 weeks and is not equipped with the Automatic Fresh Water Flush accessory or i...

Страница 73: ...oughout its life cycle the RO Membrane Element requires cleaning the frequency of which depends on the amount of production and salt rejection loss from normal day to day use At the element s end of l...

Страница 74: ...ing compound requires 30 gallons 113 5 liters of fresh non chlorinated Product Water If more than one cleaning is performed using different cleaning compounds then an additional 20 gallons 75 7 liters...

Страница 75: ...the system for a Recirculating Closed Loop configuration 10 Start the System in MANUAL MODE and operate it in the Recirculating Closed Loop configuration for 60 minutes After 60 minutes STOP the Syst...

Страница 76: ......

Страница 77: ...ith correct part information TYPE Tells Sea Recovery Corporation the production capacity of your System which provides a bench mark in diagnosing product water flow and pressure concerns VERSION Allow...

Страница 78: ...ne and bromine from your ship s potable water system before connecting theAqua Matic XL Note on Component Cleaning If detergents are used to clean the System s internal wetted components then you must...

Страница 79: ...rty Parts Warning The major documented cause of failures and problems are from the use of third party non Sea Recovery parts improper installation and improper operation Do not use parts components fr...

Страница 80: ...tions contacts and the control circuit A failed electric motor requires repair or replacement If failure is due to an external source not the motor itself attempt to correct the cause to prevent futur...

Страница 81: ...the ceramic seat into the cavity over the shaft Make sure that the polished side is toward the end of the shaft Tap into place evenly using a hollow piece of wood or plastic tool If a metal tool is us...

Страница 82: ...n operate only the Booster Pump 6 After 10 minutes of back washing stop the Booster Pump 7 Position the Multi Media Filter Valves to Rinse 8 In the Manual mode of operation operate only the Booster Pu...

Страница 83: ...an or replace when blockage occurs i e the pressure into the High Pressure Pump is equivalent to 10 PSI 69 kPa or less At slightly below 6 PSI 41 kPa the System will turn off and display a fault scree...

Страница 84: ...use cavitation and damage This pump is manufactured to very tight tolerance spacing between moving parts Any debris entering the pump will cause extensive and expensive damage to the internal parts Th...

Страница 85: ...he product water tube fitting 12 7 Remove the product water tube fitting 12 and nipple 11 from the end plug 8 Insert the three Socket Head Cap Screws 16 finger tightened into the End Plug 3 and 4 Thes...

Страница 86: ...e High Pressure Hoses to the respective fitting on the Pressure Vessel High Pressure Manifold Replace the High Pressure Manifold if it is visibly cracked broken and leaking Replace the High Pressure f...

Страница 87: ...rotate it will draw high current and the sensing POT will not rotate The System Control Logic receives a high current signal and ceases to sense POT movement As a result the System will stop and the...

Страница 88: ...lve 5 Position the Manual Override button INWARD to the manual override position by first pushing the button inward and then rotating it clockwise allowing it to lock inward close to the coil body 6 W...

Страница 89: ...or and owner and is not covered by the Sea Recovery Corporation warranty To replace the Charcoal Filter Element follow the procedures below 1 Unscrew the bowl counter clockwise 2 Remove the Charcoal F...

Страница 90: ...sleeve carefully Reassembly 1 Replace old O rings with new O rings 2 Insert the quartz sleeve close end first through the ballast box pass thru until O ring contact pass thru Screw on the ballast box...

Страница 91: ...erate the UV lamp outside the stainless steel cabinet Danger Properly ground the UV unit Failure to properly ground the UV unit can cause severe electrical shock hazard Disconnect power before servici...

Страница 92: ...eriod Use the finding to determine a reasonable schedule and frequency for periodic cleaning Clean In Place CIP cleaning is sometimes effective in removing debris from the quartz sleeve Conduct a CIP...

Страница 93: ...related to improper sample taking techniques Although several commercial sample collection apparatuses are available proper manufacturer s procedures must be followed 1 Use sterile sample bottles obt...

Страница 94: ......

Страница 95: ...ater Flush Operation Check for leaks or blockage in the Fresh Water Supply Product flow is low Check water temperature and reverse osmosis membrane Unable to communicate with the selected watermaker C...

Страница 96: ...re Sensor failed to measure the pressure Check wiring High Pressure sensor failed to measure the pressure Check wiring Temperature Sensor failed to measure the temperature Check wiring Aqua Matic XL 2...

Страница 97: ...97...

Страница 98: ......

Страница 99: ...arm press Accept System Alarm codes and likely causes Number Alarm Displayed Likely Causes 01 Automatic start requested with system locked in E Stop Please clear E Stop The E Stop button was pressed i...

Страница 100: ...st or the sensor itself may have failed The fault must be fixed and cleared before running the system again If an emergency exists the system can still be run for a limited time by activating the sens...

Страница 101: ...ly check rotation direction of the high pressure pump itself If incorrect rotation is present this can cause over pressurization of the feed line Lastly check that any high pressure check valves insta...

Страница 102: ...utomatic back pressure regulator assembly during this initialization a motor over current was detected This indicates the pressure regulator is jammed follow the instructions listed in section 15 to a...

Страница 103: ...se system pressure within allowed time The system was started in either manual mode or the system is an AquaWhisper DX Once the HP pump is activated the user has a finite time in which to adjust syste...

Страница 104: ...ctivated the emergency by pass of the booster pump outlet pressure sensor The system can only operate in this state for a limited time Consult Parker for additional information 50 HP pump inlet sensor...

Страница 105: ...r in by pass Emergency operation mode active The operator has activated the emergency by pass of the HP Pump outlet pressure sensor and is now operating the system Operation can continue until the max...

Страница 106: ...ve The operator has activated the emergency by pass of the system brine flow sensor and is now operating the system Operation can continue until the maximum preset time has elapsed 50hrs Contact Parke...

Страница 107: ...have casting slag that which has not been machined off partially covering the fingers or inside of the fitting b Solution Inspect the Inlet Thru Hull Fitting and clean all manufacturing debris and ca...

Страница 108: ...water flow a Description The Sea Strainer mesh screen element is the first line of defense to trap large suspended solids entering the Feed Line Depending on Feed Water conditions the screen may plug...

Страница 109: ...ch Pad are inaccurate a Description The minimum voltage output is below 0 5 VDC and or the maximum voltage output is above 5 VDC b Solution Check wiring and connections to and from the Transducer Repl...

Страница 110: ...ause the same symptom Low voltage is caused by an undersized power supply or generator undersized power lead wires to the System or motor loose power wire or connection at the motor or within the powe...

Страница 111: ...let 5 Problem Decreased Pressure a Description The High Pressure Pump flow and or pressure have decreased from normal As with all High Pressure Pumps over time of operation flow and pressure will decl...

Страница 112: ...aking the Product Water non potable a Descriptions a The Pressurized Feed Water and the un pressurized Product Water are separated by an O Ring which seals on the Product Water Tube at each end of the...

Страница 113: ...ater quality to worsen b Solution Replace the RO Membrane Element s if they have been attacked by chemicals or oil 4 Problem Feed Water leaks from the Pressure Vessel a Descriptions The High Pressure...

Страница 114: ...meter body causing false readings b There may be a water substantial leak prior to the Brine Flow Meter resulting in a lower than normal reading c Feed Water may be exiting the Product Water Line resu...

Страница 115: ...e incorrect measurement of the Product Water Salinity a Solution Clean the Salinity Probe contact pins annually or at any sign of incorrect reading 2 Problem The Salinity Probe may have drifted from i...

Страница 116: ......

Страница 117: ...ed which results in restriction and in turn product water recovery reduction Osmotic Pressure The transfer of the water from one side of the membrane to the other will continue until the head pressure...

Страница 118: ...d by the water temperature At any given pressure this flow increases with increasing water temperature and is reduced at lower temperatures The System over comes this factor by self adjusting the oper...

Страница 119: ...Chapter 10 Appendix 119...

Страница 120: ...lidity of this certificate and the status of the particular products being manufactured ISSUE DATE SURVEYOR FIRST ANNUAL ENDORSEMENT SECOND ANNUAL ENDORSEMENT THIRD ANNUAL ENDORSEMENT FOURTH ANNUAL EN...

Страница 121: ...eau of Shipping as of the date of issue Parties are advised to review the Rules for the scope and conditions of classification and to review the survey records for a fuller description of any restrict...

Страница 122: ...ts are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency e...

Страница 123: ...ABS Certificate of Design Assessment 123...

Страница 124: ...FCC Compliance Appendix Aqua Matic XL 2200 3600 124...

Страница 125: ...Single Phase Electrical Motor Wiring 125 Appendix...

Страница 126: ...Three Phase Electrical Motor Wiring Aqua Matic XL 2200 3600 126...

Страница 127: ...Three Phase Transformer Wiring 127 Appendix...

Страница 128: ...New System Initial Readings Form Aqua Matic XL 2200 3600 128...

Страница 129: ...Daily System Readings 129 Appendix...

Страница 130: ......

Страница 131: ...Chapter 11 Exploded Parts Views 131...

Страница 132: ...Exploded Parts View Aqua Matic XL 2200 3600 132...

Страница 133: ...1 2 BLK NYL NO SUBST 0312124269 75 ft 4 HOSE SPIRAL 1 PVC FLEX 0328027600 75 ft 5 ELB90 0 75 MPT x 1 00 BARB 0101074383 2 8 RB 3 4MPTX1 4FNPT NYL 01122934DG 1 9 TEE 3 4FPTXFPTXFPT NYL 01124237DG 1 11...

Страница 134: ...8 11 12 18 21 24 25 26 1 2 3 4 5 Exploded Parts View 134...

Страница 135: ...ON PART NUMBER QTY ITEM NO SEA STRAINER ASSY 75 BRONZE 755 SERIES 0421056739 1 1 ELB90 0 75 MPT x BARB 0101073783 2 2 SCREX HEX A 25x1 00 SS 061172143016 1 3 CLAMP HOSE SS 3 4 05181434AA 4 4 WASHER FL...

Страница 136: ...LIEF 90 CG90 6250 1920023632 4 1 ELB90 0 75 FPT x BARB NYLON 01120637DG 5 1 ADAP 0 75 MPT x BARB NYLON 0112653700 6 1 2HP 3450RPM 1PH 60HZ 56J 3535L TEFC F1 1551221110 7 4 WASHER FLAT 3 8 SS 061080056...

Страница 137: ...4722 3 1 3 MOTOR 2HP 460 60 3 1 5HP 380 50 3 1544182210 1 4 ADAPTER 1 00 MPT x BARB 0101654483 1 5 ELB90 1 00 FPT x BARB 0101064483 1 6 NUT HEX 31 18 W INSERT SS 061060050000 4 7 SCREW HEX HEAD 3 8 16...

Страница 138: ...53783 3 4 ELB90 0 75 FPT x FPT 0101013783 2 5 ELB90 0 75 MPT x BARB 0101073783 3 6 NIPPLE 0 75 NPT x CL 01013737CL 4 7 SCREX HEX A 25x1 00 SS 061172143016 8 8 TEE 0 75 FT x FT x FT 0101423783 2 9 HOSE...

Страница 139: ...6 10 14 10 6 10 4 10 13 8 14 10 6 5 7 7 5 11 12 3 2 3 3 2 3 10 4 7 9 7 1 4 139...

Страница 140: ...B90 1 4 MPT X 1 4 TU JG PLASTIC 0204020100 4 1 PLUG 25 JQ 0204990300 5 4 CLAMP HOSE SS 1 05181435AA 6 4 WASHER FLAT 10 SS 061080028000 7 4 SCREX HEX A 25x1 00 SS 061172143016 8 2 O RING 034 COMMERICAL...

Страница 141: ...2 ADAPTER 0 75 MPT x 1 00 BARB 0101653883 3 1 ELBOW PP 1 4 ODx1 4 MT 0204020869 4 1 ELB90 1 4 MPT X 1 4 TU JG PLASTIC 0204020100 5 1 PLUG 25 JQ 0204990300 6 4 CLAMP HOSE SS 1 05181435AA 7 4 WASHER FLA...

Страница 142: ...LUSH 10 IN ASSY UWIII UWDX SQ P598290008 8 1 GROUNDING PLATE 2021084003 9 1 PANEL COVER AQM XL COMPACT 2020078101B 10 1 FRAME AQM XL COMPACT ASSY B586078102 11 1 PUSHBUTTON ESTOP 16mm MUSH HEAD 900120...

Страница 143: ...11 4 12 2 11 1 5 16 14 20 3 15 13 9 17 18 19 7 10 6 8 143...

Страница 144: ...TRANSDUCER MANIFOLD AQMII DX B147130002 1 1 BACK PRESSURE REGULATOR ASSY AQMXLM B476160005 2 1 PLUMBING CONNECTION ASSY AQMXLM B516310003 4 1 FRAME ASSY AL6061 AQMXLM B586310001 3 1 CHASSIS 208 230 3P...

Страница 145: ...1 NIP HEX 375 NPT X CLOSE SS 01173818CL 9 1 TEE RUN 0 38 MT x 0 38 FT x 0 38 FT SS316 01174918PH 10 1 CONN 8 FLARE x 0 38 MT SS 1317092569 11 2 CLAMP HOSE SS 3 4 05181434AA 12 8 NUT HEX 31 18 W INSER...

Страница 146: ...2 8 11 10 7 1 5 3 12 9 18 13 14 14 16 15 17 16 14 19 15 17 4 6 Exploded Parts View 146...

Страница 147: ...01174918PH 10 1 CONN 8 FLARE x 0 38 MT SS 1317092569 11 2 CLAMP HOSE SS 1 05181435AA 12 8 NUT HEX 31 18 W INSERT SS 061060050000 13 2 NUT HEX 38 16 W INSERT SS 061060057000 14 16 WASHER FLAT 5 16 IN S...

Страница 148: ...11 9 12 10 5 4 6 1 8 22 3 2 21 16 20 14 19 16 17 15 7 15 13 23 24 Aqua Matic XL 2200 3600 148...

Страница 149: ...1 10 CLAMP HOSE SS 1 05181435AA 2 11 NUT HEX 38 16 W INSERT SS 061060057000 2 12 WASHER FLAT 3 8 SS 061080056000 8 13 SCREW HEX HEAD 3 8 16x2 1 4 SS 061142157044 2 14 SPACER MOTOR MOUNT AQM II 2020043...

Страница 150: ...10 26 11 9 5 5 4 20 1 7 18 3 2 16 13 15 12 14 13 23 24 21 24 25 Exploded Parts View 150...

Страница 151: ...LATION MOUNT 38 16UNC THD NEOPRENE 50 DURO 20 2449 4 8 TRANSDUCER 0 2000 PSI 437 SAE 2317100300 1 9 ADAPTER 0 75 MPT x BARB 0101653783 1 10 TEE RUN 0 38 MT x 0 38 FT x 0 38 FT SS316 01174918PH 1 11 CO...

Страница 152: ...12 10 13 11 5 5 4 6 1 9 20 3 2 17 16 14 18 15 19 17 16 14 18 15 8 7 Exploded Parts View 152...

Страница 153: ...TE SUPPORT VESSEL 3 IN 23 00x2 50x0 25TH 0520052000 2 2 BRACKET MVA U CLAMP 3 IN 05202401GR 6 3 INTERCONNECT MVA SS 2417430800 2 4 FELT ADHESIVE 0 125 X 0 75 STRIP 2615180100 6 5 WASHER FLAT 1 4 SS 06...

Страница 154: ...CT MVA SS 2417430800 2 4 900 GPD MEM VESSEL ASSY SEAFARI B196900004 1 5 900 GPD MEM VESSEL ASSY SEAFARI B196900004 2 6 FELT ADHESIVE 0 125 X 0 75 STRIP 2615180100 6 7 ELBOW PP 3 8 ODx1 4 FT 0204011769...

Страница 155: ...RT VESSEL 3 IN 23 00x2 50x0 25TH 0520052000 2 3 BRACKET MVA U CLAMP 3 IN 05202401GR 8 4 INTERCONNECT MVA SS 2417430800 3 5 FELT ADHESIVE 0 125 X 0 75 STRIP 2615180100 8 6 ELB90 8 FLARE x 0 25 MT SS 13...

Страница 156: ...NECT MVA SS 2417430800 3 4 900 GPD MEM VESSEL ASSY B196900004 2 5 900 GPD MEM VESSEL ASSY SEAFARI B196900004 2 6 FELT ADHESIVE 0 125 X 0 75 STRIP 2615180100 8 7 ELBOW PP 3 8 ODx1 4 FT 0204011769 2 8 E...

Страница 157: ...43900 1 3 BRP GEAR ASSY B079400004 1 4 ELB90 0 25 MPT X 0 25 FPT SS 0117230819 2 5 NIPPLE 0 25 NPT X 1 50 SS316L 0117380869 1 6 ELBOW PP 3 8 ODx1 4 MT 0204021769 1 7 WASHER FLAT 10 SS 061080028000 4 8...

Страница 158: ...ST SS 25 FT x 25 MT x 25 FT 0117490869 7 1 ADAPTER 4375 FPT X 25 MPT 0117630800 8 1 ELBOW PP 3 8 ODx1 4 MT 0204021769 9 1 ELB90 8 FLARE x 0 25 MT SS 1317022469 10 2 NUT HEX 10 32 W INSERT SS 06106003...

Страница 159: ...6 1 16 14 12 9 11 12 13 12 5 4 2 15 3 15 7 8 10 159...

Страница 160: ...4 0 5360300800 1 6 NIPPLE 375 NPT x 1 0101378500 2 7 ELBOW PP 3 8 ODx3 8 MT 0204021869 3 8 PLUG 0 375 MT 0101341883 1 9 SALINITY PROBE ASSY B511080004 1 10 MANIFOLD AQMXL 3 8 DV PVC PRESS LOW 6X2 5X2...

Страница 161: ...378500 10 1 ADAPTER 0 50 MPT x 1 00 BARB 0101652783 11 2 ELBOW PP 3 8 ODx3 8 MT 0204021869 12 1 FITTING PP 3 8 ODx3 8 MT 0204091869 13 1 FITTING PP 1 2 ODx3 8 MT 0204092469 14 1 FITTING PP 1 2 ODx1 2...

Страница 162: ...14 19 21 12 8 6 9 20 12 3 4 7 1 18 10 10 23 7 26 17 5 16 24 25 24 25 17 13 11 2 15 22 Exploded Parts View 162...

Страница 163: ...MANIFOLD LP PICKUP AQM II REV PR 5301400802 1 1 TRANSDUCER 0 200 PSI 437 SAE 2317100200 2 2 ADAP 5 MPT X 75 BARB NYLON 01126526DG 2 3 FITTING PP 1 4 ODx1 4 MT 0204090869 1 4 SC PHIL PAN 8 32 X 5 8 SS...

Страница 164: ...ON FILE DWG NAME ITEM NO 1 MANIFOLD PRESSURE PICK UP AQM Rev C 5301400600 1 3 TRANSDUCER 0 200 PSI 437 SAE 2317100200 2 3 FITTING PP 1 4 ODx1 4 MT 0204090869 3 3 TUBE 25 BLACK 0312121969 4 Aqua Matic...

Страница 165: ...N 08251950AS 1 4 NIPPLE 0 50 NPT x CL 01013725CL 1 5 ELB90 0 50 MPT x 0 75 BARB NYLON 0112072600 2 6 CLAMP HOSE SS 3 4 05181434AA 4 7 WASHER FLAT OS 1 4 SS 061100043000 4 8 SCREW HEX HEAD 25 20x1 SS 0...

Страница 166: ...6 7 2 3 2 5 10 10 12 1 11 8 9 8 11 6 7 4 2 13 14 Aqua Matic XL 2200 3600 166...

Страница 167: ...783 4 2 ADAP 75 FNPT x 75 BARB PVC 0101613783 2 3 VALVE 3 WAY BALL 75 MPT 14011334AR 2 4 PIPE SUPPORT 1 125 0501164200 4 5 HOSE CLAMP 75 SS 05181434AA 12 6 NUT HEX 8 32 W INSERT SS 061060026000 4 7 SC...

Страница 168: ...TUBE x 250 MT PLASTIC 0204091769 1 11 ELBOW PP 3 8 ODx1 2 MT 0204021969 1 12 ELBOW PP 3 8 ODx1 4 FT 0204011769 1 13 NIP 0 75 NPT X 0 75 NPT NYLON 01123737DG 1 14 PLUG 0 25 MT 0101340883 1 15 SCREX HE...

Страница 169: ...6 15 7 13 18 11 16 27 25 26 21 1 4 3 2 3 12 19 9 17 14 23 8 20 9 19 5 27 16 24 22 10 169...

Страница 170: ...NG LID 3 8 X 10 0713020573 2 2 DUAL BRACKET PRE FILTER CHRCL PLNKTN 20200402101 1 3 ELEMENT PH 9 3 4 08251950AS 1 4 CHARCOAL FILTER 10 IN 0803004773 1 5 ELB90 3 8 TUBE X 3 8 MPT PLASTIC 0204021869 1 6...

Страница 171: ...B610140004 NMEA 2000 ENABLED DESCRIPTION PART NO QTY ITEM NO MICRO CAP 31316809MT 1 1 MICRO BULKHEAD FEED THRU ASSY 31316801MT 1 2 MICRO SINGLE ENDED CORDSET MALE 31316812MT 1 3 1 2 3 171...

Страница 172: ...2014 3 1 HMI DISPLAY 7 IN PROGRAMMED 90012015 4 1 DONGLE HMI RS485 POWER AQ 90012289 5 2 NUT HEX 6 32 W INSERT SS 061060020000 6 2 WASHER FLAT 6 SS 061080018000 7 4 WASHER FLAT 10 SS 061080028000 8 2...

Страница 173: ...VER HMI AQM 11012072 2 1 CONVERTER 12V TO 24V HMI 90012014 3 1 HMI DISPLAY 7 IN PROGRAMMED 90012015 4 1 DONGLE HMI RS485 POWER AQ 90012289 5 2 NUT HEX 6 32 W INSERT SS 061060020000 6 2 WASHER FLAT 6 S...

Страница 174: ...ZEL4INCH NEW REMOTE HMI 11012164 2 1 CONVERTER 12V TO 24V HMI 90012014 3 1 HMI DISPLAY 4 3 PROGRAMMED 90012016 4 1 DONGLE HMI RS485 POWER AQ 90012289 5 2 NUT HEX 6 32 W INSERT SS 061060020000 6 2 WASH...

Страница 175: ...INLET OUTLET 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 1 2 TUBE 1 2 TUBE 1 2 TUBE 1 4 TUBE 1 4 TUBE SEA STRAINER BOOSTER PUMP COMERCIAL PRE FILTER PRODUCT WATER INLET MANIFOLD FRO...

Страница 176: ...SEMBLY FRESH WATER FLUSH 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 3 4 HOSE 1 4 TUBE 1 4 TUBE 1 4 TUBE 3 8 HP HOSE 3 8 HP HOSE 1 2 TUBE 1 2 TUBE 1 2 TUBE 1 2 TUBE 3 8 TUBE 3 8 TUBE 3 8 TUB...

Страница 177: ...Chapter 12 Electric Diagrams Foldouts 177...

Страница 178: ...Aqua Matic XL Series Three Phase Wiring Diagram...

Страница 179: ...179...

Страница 180: ......

Страница 181: ...I Filter WHT BLK WHT RED RED BLK GRN RED 12V BLK YEL 12V ORG 12V YEL BLK BLK YEL BLK BLK RED RED RED RED RED 12V LP Transducer 2 HP Transducer 1 RED WHT BLK LO PRESS SENSOR 1 BLK WHT RED RED WHT BLK R...

Страница 182: ...ponsible for evaluation of its contents except that there is no obligation to maintain the confidentiality of any information that becomes publicly known through no fault of recipient By receiving and...

Страница 183: ......

Страница 184: ...Sea Recovery 2630 E El Presidio Street Carson CA 90810 sales searecovery com www searecovery com PN B6513100001...

Отзывы: