SYMPTOM
POSSIBLE SOLUTION
Controller does not power up.
Check: tuner is connected to power supply.
controller is connected to tuner.
power supply is plugged into 110 VAC outlet.
Controller remains in
“Power Up, Please Wait”
condition.
Disconnect power supply for 15 seconds, then reconnect.
Verify voltage on coax at dome unit is 24 volts.
Inspect rotary joint cable, then reseat (inside dome unit).
Inspect all coax cables and verify connections are snug but not overly tight
(inside and outside dome unit).
Controller displays “Load Error.”
Disconnect power supply for 15 seconds, then reconnect.
Inspect rotary joint cable, then reseat (inside dome unit).
Controller displays “AZ FAULT.”
Dish cannot rotate.
Verify shipping bolts are removed (see pages 5 and 6).
Disconnect power supply for 15 seconds, then reconnect.
Perform
Mechanical Calibration
(page 26).
Perform
OPTION 21 RE-INITIALIZE and 0-RECALIBRATE
(pages 24-25).
Reseat ribbon cables (inside dome unit).
Display reads “EL FAULT.”
Make sure shipping tie strap is removed (see pages 5 and 6).
Disconnect power supply for 15 seconds, then reconnect.
Perform
Mechanical Calibration
(page 26).
Restart system. If problem persists, perform
OPTION 21 RE-INITIALIZE and
0-RECALIBRATE
(pages 24-25).
Reseat ribbon cables inside dome unit.
Содержание 9762-SW
Страница 2: ......
Страница 15: ...Page 13 9762 SW INTERNAL WIRING Fig 10 IMPORTANT AVOID SHARP BENDS WHEN ROUTING COAX...
Страница 17: ...Page 15 Fig 11 TYPICAL 4 RECEIVER HOOKUP IMPORTANT AVOID SHARP BENDS WHEN ROUTING COAX...
Страница 26: ...Page 24 OPTION 21 RE INITIALIZE and 0 RECALIBRATE...
Страница 27: ...Page 25...
Страница 31: ......
Страница 32: ...11200 Hampshire Avenue South Bloomington MN 55438 2453 Phone 800 982 9920 Fax 952 922 8424 www kingcontrols com...