background image

Section 7 — Handling and Storage

Handle, transport and store carefully and securely to avoid accidental knocking over or other
severe physical impacts. Do not expose to direct heat sources. Do not over-pressurize.

Section 8 — Exposure Controls/Personal Protection

Respiratory: None

Protective Gloves: Leather gloves are recommended when handling cylinders.

Eye Protection: Eye protection is recommended when handling cylinders.

Other Protective Clothing or Equipment: Safety shoes are recommended when handling
cylinders.

Work Hygienic Practices: Wash thoroughly after handling. Wash contaminated clothing

before reuse.

Section 9 — Physical & Chemical Properties

Appearance:

Colorless gas

Physical State:

Gas

Odor:

Odorless

Solubility in Water: 260 mg/L

Section 10 — Stability and Reactivity

Stability: Stable under normal conditions of handling and use.

Conditions to Avoid: None

Section 11 — Toxicological Information

VALUE (LD50 or LC50)

Animal

Routes

Components

>788.696 ppm/4H

Rat

Acute Inhalation

1.1.1.2.3.3.3 Heptafluoropropane

The human health hazards of this product are expected to be similar to other liquefied gases
including N2, C02, CFCs, HCFCs, and HBFCs. Therefore, direct eye or skin contact with the
liquid or cold gas can cause chilling or possibly frostbite of exposed tissues.   Inhalation of
high concentrations can be harmful or fatal due to oxygen deprivation and/or heart irregulari-
ties (arrhythmias). Misuse of the products by deliberately inhaling high concentrations of this
gas could cause death without warning. Persons with preexisting cardiac or central nervous
system disorders may be more susceptible to effects of an overexposure.

Section 12 — Ecological Information

No ecological information is available.

Section 13 — Disposal Considerations

Dispose of waste and empty cylinders as allowed by current Local, State/Province, or Fed-
eral laws and regulations.

Section 14 — Transport Information

Proper Shipping Name: Heptafluoropropane
ID Number: UN3296
Hazard Class: 2.2
Packing Group: N/A
Labels: Non-flammable gas
Packing Instructions: 200

12

Содержание FM200

Страница 1: ... MUST BE INSTALLED AND MAINTAINED ACCORDINGLY READ AND COMPLY WITH THESE INSTRUCTIONS WARNINGS AND LIMITATIONS BEFORE INSTALLING SUITABLE FOR USE FT MODELS 32 F 130 F 0 C 54 C ALWAYS MAINTAIN THIS OWNER S MANUAL NEARBY FOR OPERATOR REFERENCE APPROVALS FACTORY MUTUAL FM 3022058 U S COAST GUARD U S C G 162 029 241 REV A PRINTED IN USA PART NO 123 186 ...

Страница 2: ...ed compartment The specification table in this manual lists the minimum and maximum approved compartment volume size allowable for each model Volume can be determined by multiplying the compartment s length x width x height which equals the volume in cubic feet or meters LxWxH V Exception If the boat manufacturer has placed a permanently affixed label in the compart ment specifying the gross volum...

Страница 3: ...ment electric supply etc When using the pressure switch as an electrical disconnect for any equipment shutdown function a means of overriding bypassing shunting the pressure switch must be provided in order to return the affected equipment to an operational mode after extinguisher discharge has occurred The pressure switch is a single pole single throw SPST type that is normally closed NC with the...

Страница 4: ...ERSIDE OF COVER OR COM PARTMENT HATCH THAT COULD BE THROWN CLEAR DUE TO POSSIBLE EX PLOSION 8 DO NOT MOUNT WHERE AN ACCUMULATION OF STANDING WATER COULD BLOCK SENSOR OR CAUSE CORROSION 9 EXTINGUISHER TO BE MOUNTED IN THE VERTICAL POSITION ONLY 10 DO NOT USE FOR PRIMARY ENGINE COMPARTMENT PROTECTION EXTINGUISHER INSTALLATION Step 1 Carefully remove extinguisher from carton and visually check for da...

Страница 5: ...ssembly Note Do not kink tub ing if kink occurs remove effected area with razor Step 10 Tighten fitting and tube to cylinder using 1 2 12mm wrench Preferred torque value is 3 4 1 2 inch pounds of force Overtightening may cause tube to rupture Step 11 Activate system Using a straight screwdriver open valve VERY SLOWLY counter clockwise 1 4 of a turn to allow detection tube to fill with nitrogen Not...

Страница 6: ...oper range 2 Check fuse and indicator light and replace if defective lamp replacements available from factory 3 Check for loose electrical connections 4 Remove and weigh system cylinder as described in MAINTENANCE Section of the manual INDICATOR LIGHT INSTALLATION Select a location at the helm on or near the console that is in full view of the helmsman the location selected must have access for el...

Страница 7: ...nd tools Attach one wire lead from the in line fuse to the ignition position on the starter switch Connect other lead from the in line fuse to the indicator light Connect remaining indica tor lead to one of the Sea Fire cylinder pressure switch connector wires Connect the remaining cylinder pressure switch lead to common ground which may be the negative battery buss at the control panel or directl...

Страница 8: ... audible system status indicator with override switch for engine restart Avail able with 3 5 or 8 control circuits in 12 or 24 VDC models ESRS WT III V VIII Same as ESRS MARK shutdown system but also includes a factory installed nominal 20 second release timer on the engines control cir cuits For use in diesel engines that shutdown through activation of a momentary device i e push button lever etc...

Страница 9: ...ystem for one half of the current suggested list price RETURN TO UNITED STATES EUROPE SEA FIRE MARINE SEA FIRE EUROPE LTD Division of Metalcraft Inc Unit 7 io Centre Stephenson Road 9331 A Philadelphia Road Fareham Hampshire Baltimore Maryland 21237 USA PO15 5RU United Kingdom Website www sea fire com EQUIPMENT LIST FOR INSTALLATION 1 Drill motor 2 Drill bit 25 64 390 for rubber grommet 3 Drill bi...

Страница 10: ...MPERATURE RANGE 32 F 130 F 0 C 54 C STANDARD EQUIPMENT LIST SUPPLIED WITH EACH SYSTEM 1 ONE TUBING KIT PART 130 121 10 FOOT TUBE OR 130 122 15 FOOT TUBE 2 ONE BRACKET ASSEMBLY Model Bracket Part FT 25 122 010 FT 50 122 010 FT 75 122 010 FT 100 130 011 FT 125 130 012 FT 150 130 013 10 ...

Страница 11: ... property damage if the valve is broken due to improper handling or storage Section 4 First Aid Measures Skin contact Flush with water treat for frostbite if necessary by gently warming affected areas Consult a physician Eye contact Immediately flush eyes with plenty of water for at least 15 minutes Consult an ophthalmologist Inhalation Remove victim s to fresh air as quickly as possible If not br...

Страница 12: ...nimal Routes Components 788 696 ppm 4H Rat Acute Inhalation 1 1 1 2 3 3 3 Heptafluoropropane The human health hazards of this product are expected to be similar to other liquefied gases including N2 C02 CFCs HCFCs and HBFCs Therefore direct eye or skin contact with the liquid or cold gas can cause chilling or possibly frostbite of exposed tissues Inhalation of high concentrations can be harmful or...

Страница 13: ... DISCLAIMER OF EXPRESSED AND IMPLIED WARRANTIES Metalcraft Sea Fire Marine Inc has taken reasonable care in preparing this document how ever since the use of this information and the conditions of use of the product are not within the control of Metalcraft Sea Fire Marine Inc it is the user s obligation to determine the conditions of safe use of this product The information in this document is off...

Страница 14: ...MARINE SEA FIRE EUROPE LTD Division of Metalcraft Inc Unit 7 io Centre Stephenson Road 9331 A Philadelphia Road Fareham Hampshire Baltimore Maryland 21237 USA PO15 5RU United Kingdom Website www sea fire com 14 ...