STS32/STS32H Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu. (CONTINUED)
Installer
Setup
Number
Installer Setup
Name
Settings Notes
Initial
Setting
Record
0330 Daylight
Savings
1-daylight savings is on (factory setting).
0-daylight savings is off.
Set to 0 in areas that do
not follow daylight
savings.
0340
Remote
Temperature
Sensor (Outdoor or
Indoor)
0-no remote temperature sensor.
1-outdoor temperature sensor for display only.
2-outdoor temperature sensor for control.
Outdoor sensor used for Heat Pump Lockout
settings. (See Heat Pump Temperature Lockout
section for more details.).
3-indoor temperature sensor.
Defaults and Options
depend on System Type
selection.
Indoor Temperature
Sensor uses an averaging
network and does not
include on-board sensor.
0350
Heat Pump
Compressor
Lockout or (Balance
Point)
0-no compressor lockout.
15°F (-9.5°C)
20°F (-6.5°C)
25°F (-4°C)
30°F (-1°C)
35°F (1.5°C)
40°F (4.5°C)
45°F (7°C)
Default depends on other
selections. Shown if
control is selected. (See
section for more
information.)
54
STS32/STS32H Touchscreen Programmable Thermostat
Table 3. Installer Setup Menu. (CONTINUED)
Installer
Setup
Number
Installer Setup
Name
Settings Notes
Initial
Setting
Record
0360
Heat Pump
Auxiliary Lockout
0-no auxiliary heat lockout.
40°F (4.5°C)
45°F (7°C)
50°F (10°C)
55°F (13°C)
60°F (15.5°C)
Shown if electric is chosen for
backup heat source and outdoor
temperature sensor for control is
selected. (See Advanced
Features section for more
information.)
0380
Indoor
Dehumidification
Control
0-No indoor dehumidification control.
1-Dehumidification control activated.
Available on select models. If
dehumidification control is
activated and auto- changeover
is selected in Installer Setup
Number 0300, the dead band
minimum is defaulted to 5°F
(3°C) in Number 0310.
0500
Filter Change
Reminder
0-furnace filter reminder off.
1-10 run time days.
2-30 run time days.
3-60 run time days.
4-90 run time days.
5-120 run time days.
6-365 run time days.
Run time based on call for fan.