SE audio AMP100V Скачать руководство пользователя страница 12

40 Watt Power Amplifier 

4. System Operations 

4.1 Operations of Front Panel 

The buttons provides the control of volume/EQ control and switching. The LED indicator 
will show the connecting status. The following content introduces audio switching and 
EQ control in detail. 
Operations: Press the corresponding button again for cyclic switching. 
 

4.1.1 Audio switching 

There are three switchable audio inputs, one 2xRCA input, one 3.5mm jack input, and 
one digital fiber audio input, switchable through the buttons as below: 

   

Figure 6 Audio Source Selection Button 

 

4.1.2 Volume/EQ controlling 

The line volume and MIC volume can be controlled by the buttons.   
The MIC Volume/LINE volume/LINE bass/LINE treble will be selected by the buttons, 
and controlled up/down/mute by the function buttons. Please check the picture below: 

 

 

 

Figure 7 Audio Mode and Volume Adjustment buttons 

 

For example, to turn up the line volume, you should select the “LINE” first, and then 
press the button “

”. 

 

 

Audio Source Selection:

 

1: Dual mono audio 
2: Stereo audio 
3: Digital fiber audio. 

Audio Mode Switching 

Volume Adjustment: 

: Turn down the volume 

: Turn up the volume 

MUTE: Mute the output 

Содержание AMP100V

Страница 1: ...AMP100V 40 Watt Power Amplifier All Rights Reserved Version AMP100V_2020V1 0 User Manual ...

Страница 2: ...Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inte...

Страница 3: ... install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards Install the device in a place with fine ventilation to avoid damage caused by overheat Keep the module away from liquids Spillage into the housing may result in fire electr...

Страница 4: ...tput 5 3 3 2 Audio Inputs 6 3 4 System Applications 7 4 System Operations 8 4 1 Operations of Front Panel 8 4 1 1 Audio switching 8 4 1 2 Volume EQ controlling 8 4 2 Operations of IR Remote 9 4 3 Operations of Control Software 10 4 3 1 Connection with Computer 10 4 3 2 RS232 Control Software 10 4 3 3 Running Environment 11 4 3 4 Function Settings 11 4 3 5 RS232 Communication Commands 12 5 Specific...

Страница 5: ...rate with both voltages to meet different requirements 1 1 Features Mono audio output at 40Watt Switchable between 70V and 100V Ducking function 16 ID codes for controlling between different amplifiers 3 level MIC input supports condenser microphone dynamic microphone and wireless microphone MIC port can support balance unbalance signal suppress the external noise effectively Two stereo audio inpu...

Страница 6: ...t Power Amplifier 2x Mounting ears with 4 Screws 4x Plastic Cushions 2x Pluggable Terminal Blocks 1x RS232 Cable 1x Power Adapter DC 24V 2 71A 1x User manual Note Please contact your distributor immediately if any damage or defect in the components is found ...

Страница 7: ...cator will be on No 1 is for dual mono audio input 2 RCA connectors for L R No 2 is for stereo audio input 3 5mm mini jack and No 3 is for digital fiber audio input Audio Control Adjust the volume of the MIC Line or the level of Bass and Treble with this button Volume Adjustment To turn up down or mute the corresponding audio Turn down the volume Turn up the volume MUTE Mute the output 1 2 3 ...

Страница 8: ...are IR To connect with the IR receiver works together with the IR remote Power Port To connect with the power adapter DC24V L R RCA Dual mono audio input which can be connected with audio source device such as a PC Digital Audio Input Fiber connector for digital audio input PCM format only it can be connected with a device with fiber port such as blue ray player RS232 3 pole captive screw connecto...

Страница 9: ... power on 3 2 System Diagram Figure 3 System Diagram 3 3 Audio Connection 3 3 1 Audio Output The amplifier supports mono audio output and the output voltage is 70V or alterative 100V With its dual purpose design it can be applied in different areas The end COM is for grounding The amplifier to be connected is mono audio output with a rated power at 40Watt so the amplifier can be connected with sev...

Страница 10: ...t ports Figure 5 Audio Input Ports 48V phantom power input When the switch turns to 48V It has a good frequency characteristic high input impedance and high sensitivity in this mode the MIC input will provide a 48V phantom power This is usually used for power supply for condenser microphone Connection is connects to positive connects to negative and to ground Note In this mode only condenser micro...

Страница 11: ...icrophone output There are two different connections a Unbalanced connection and connect to ground and connects to signal and connect to ground and connects to signal b Balanced connection connects to positive connects to negative and connects to ground Digital Audio Input The amplifier provides with a fiber optical port to connect with digital audio source device With the SPF optical fiber the au...

Страница 12: ...input switchable through the buttons as below Figure 6 Audio Source Selection Button 4 1 2 Volume EQ controlling The line volume and MIC volume can be controlled by the buttons The MIC Volume LINE volume LINE bass LINE treble will be selected by the buttons and controlled up down mute by the function buttons Please check the picture below Figure 7 Audio Mode and Volume Adjustment buttons For examp...

Страница 13: ...receiver when use to avoid getting out of control as there is no signal detected 3 5mm jack Insert it into the specialized PA3 socket 3 5mm to connect the IR receiver with PA3 Mute Mode MIC Mute the microphone volume LINE Mute the line volume SPEAKER Unmute Use to transmit the infrared signal send by the remote controller Audio Controlling Modes MIC turn up down the microphone volume LINE turn up ...

Страница 14: ...c COM software Figure 10 Connection of RS232 Port 4 3 2 RS232 Control Software Installation Connect the input source devices and the output device according to the system diagram Copy the RS232 control software to one computer and then connect the RS232 port of this computer and the amplifier Double click the EXE program to execute the software Here we take the software CommWatch exe as example Th...

Страница 15: ...mplifier 4 3 4 Function Settings With the control software we can easily switch the input channel mute the output check the working status and adjust the volume etc Please refer the details in RS232 Communication Commands The interface of the control software is showed as below Figure 12 Main Interface of Control Software Parameter Configuration area Monitoring area indicates if the command sent w...

Страница 16: ...up Volume of MIC 51 602 MIC volume down Volume of MIC 51 603 Line volume up Volume of LINE 51 604 Line volume down Volume of LINE 51 605 Bass level up Bass of LINE 4 606 Bass level down Bass of LINE 4 607 Treble level up Treble of LINE 4 608 Treble level down Treble of LINE 4 609 Initialization back to the default setting Init OK 610 Enable disable the ducking function Ducking off Ducking on 4 x x...

Страница 17: ...ID code If the address of the ID code is 0 any RS232 command is available If the address is in 1 F it has one unique ID code If the ID code is not the same with the address no RS232 command will work While the ID code is in 1 F please add ID before sending the command For example if the ID code is 5 the RS232 command needed is 604 the correct command is in this format 5 604 There is no need to add...

Страница 18: ...dio General Frequency Response 120Hz 20KHz CMRR 70dB 20Hz 20KHz SNR 80dB Max Bandwidth 120Hz 20KHz Rated Power Output 40Watt THD Noise 1 1KHz 0 3 20KHz at nominal level Voltage Gain 26dB Control Function RS232 Control 1 3 pole 3 81mm Captive Screw Connector Front Panel Control Buttons ID Code Control 16 ID Codes for control Optional IR Remote TCP IP controlled by programmable interface General Tem...

Страница 19: ...or no respond to any operation Failed power connection Make sure the power cord connection is good Static becomes stronger when connecting the video connectors Bad grounding Check the grounding and make sure it is connected well Output audio is interfered Cannot control the device by front panel buttons RS232 port or IR remote Broken unit Send it to the dealer for repairing Note If your problem st...

Страница 20: ...ar Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product model showed on the warranty card does not match with the model of the product for repairing or had been altered Damage caused by force majeure Servicing not authorized by distributor Any other causes which does not relate to a product defect Shipping fees installation or labor...