background image

 

 

 

 

 

6. Maintenance schedule 

6.1. Reminder of use 

The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide 

and for generating sets operating with fuel and oil which conform to the specifications given in this manual. 

If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened. 

 

6.2. Maintenance table 

Component 

Operations to be carried 

out on reaching the 1

st

 

due date  

With each usage 

Every month 

or 

Every  

10 hours 

Every 3 months 

or 

Every  

50 hours 

Every year 

or 

Every  

300 hours 

Generating set 

Cleaning 

 

 

 

 

 

Check the level 

 

 

 

 

 

Engine oil 

Renew 

 

 

 

 

 

 

Fuel strainer  

Cleaning 

 

 

 

 

 

Checking 

 

 

 

 

 

Air filter  

Cleaning 

 

 

 

 

 

Spark plug 

Check and clean 

 

 

 

 

 

Valves* 

Checking* 

 

 

 

 

 

* These operations must be entrusted to one of our agents 

If used occasionally only, drain-out the engine oil at least once a year.  

 

7. Maintenance procedures 

 

Warning 

Before carrying out any maintenance operation: 

-  switch off the generating set. 

-  disconnect the cap(s) of the spark plug(s) and disconnect the starter battery (if fitted). 

Only use original parts or equivalent parts: risk of damage to the generating set. 

 

7.1. Checking bolts, nuts and screws 

To prevent faults or breakdowns, carefully check all the nuts, bolts and screws on a daily basis. 

!

 

Inspect the entire generating set before and after each use. 

"

 

Tighten any loose nuts or bolts. 

Danger: The cylinder head bolts must be tightened by a specialist. Refer to the agent for your region. 

 

7.2. Renewing the engine oil 

Adhere  to  the  environment  protection  guidelines  (

see 

§

  Protecting  the  environment)

 

and  drain  the  oil  into  an  appropriate 

container. 

!

 

Open the inspection cover (fig. A – no. 2). 

"

 

With the engine still warm, remove the filler and draining plug (fig. B – no. 2). 

#

 

Gently tilt the generating set to empty the oil into the appropriate container. 

$

 

After complete draining, fill it with the recommended oil (see 

§ Specifications), 

check the level. 

%

 

Refit the filler and draining plug (fig. B – no. 2). 

&

 

Check for oil leakage. 

'

 

Wipe any oil traces with a clean cloth. 

(

 

Close the inspection cover. 

 

 

Содержание ineo 3000

Страница 1: ...5 1 16 67 78 80 0 2 21 12 23 3 012 34506 7 8 19 9 19 M Ma an nu ue el l d d u ut ti il li is sa at ti io on n e et t d d e en nt tr re et ti ie en n N No ot ti ic ce e o or ri ig gi in na al le e 9 9...

Страница 2: ...2 4 6 7 2 5 3 10 4 A 13 12 1 8 9 11 A B C...

Страница 3: ...3 4 3 B C OFF ON 1 2 1 2 4...

Страница 4: ...4 4 D E 1 2 1 2...

Страница 5: ...ic exhaust gases Do not use in a confined or poorly ventilated area 3 Stop the motor before filling with fuel A Generating set model B Generating set output C Voltage D Amperage E Current frequency F...

Страница 6: ...es to prevent electrocution Danger The generating sets supply electrical current when in operation risk of electrocution Never touch stripped cables or disconnected connectors Never handle a generatin...

Страница 7: ...ined under the reference conditions outlined in ISO 8528 1 2005 Total barometric pressure 100 Kpa Air ambient temperature 25 C 298K Relative humidity 30 Generating set performance is reduced by approx...

Страница 8: ...lace the generating set on a flat horizontal surface which is firm enough to prevent the set sinking down under no circumstances should the set tilt in any direction by more than 10 Store the addition...

Страница 9: ...ng set is properly earthed fig A no 1 see Earthing the generating set Set the fuel tank aeration pointer to O ON N position fig A no 4 fig C no 1 Open the fuel tap fig A no 3 Set the choke fig A no 6...

Страница 10: ...y increases 4 3 Switching off Shut down and disconnect the devices Allow the engine to run idle for 1 or 2 min Set the fuel tank aeration pointer to O OF FF F position fig A no 4 fig C no 1 Close the...

Страница 11: ...rrying out any maintenance operation switch off the generating set disconnect the cap s of the spark plug s and disconnect the starter battery if fitted Only use original parts or equivalent parts ris...

Страница 12: ...xplosion Remove the inspection cover fig A no 2 Remove the filter cover fig D no 1 Remove the filter element fig D no 2 and check the type of clogging Dry clogging Use a low pressure dry compressed ai...

Страница 13: ...ed to the generating set while starting Disconnect the load The oil level is too low Check the oil level and top up if necessary Fuel tank aeration pointer in O OF FF F position Place the pointer in O...

Страница 14: ...63 25 3 50 0 70 2 0 12 EC Declaration of conformity Name and address of manufacturer SDMO 12 bis rue de la Villeneuve CS 92848 29228 BREST CEDEX 2 FRANCE Description of the equipment Generating set Ma...

Отзывы: