P:\INST INSTRUCTIONS\ELECTRIFIED LOCKSETS\INST-ZR7500
REV C
05-22
Page 6
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
Important Note:
Because of design, field OHM tests of
AC
solenoids may
produce erratic readings and cannot be used to determine
the solenoids condition.
RED
WHT
BLU/BLK
YEL/BLK
ORG/BLK
Indicates Door Opened
Common
Indicates Door Latched
BLU/BLK
YEL
ORG
Indicates door unlocked
Common
Indicates door secure
Optional (S) Latch & Locked Status
SPDT 5 Amps @ 125VAC
Optional (L) Latch Status Sensor
SPDT 5 Amps @ 125VAC
Voltage and current rating stamped on solenoid
Ground screw is provided on 115 VAC locks
Standard wiring
Optional: SC-10 - 10ft Cable, Input Power Socket Connector
+
-
COM
N/C
N/O
Optional: SC-10-5 - 10ft Cable, Input Power & Monitoring Socket Connector
RESISTANCE IN
OHMS 5%
+-
AMPS
24VDC
54.5
.44
24VAC
13.6
.45
115VAC
293
.20
VOLTAGE
+
-
RED
BLK
+
-
RED
WHT
COM
N/C
N/O
BLK
BRN
GRN
Common
Indicates Door Opened
Indicates Door Latched
Indicates Door Unlocked
Indicates Door Secure
Common
Optional (L) Latch Status Sensor
SPDT 5 Amps @ 125VAC
Optional (S) Latch & Locked Status
SPDT 5 Amps @ 125VAC