P:\INST INSTRUCTIONS\EXIT DEVICES\INST-S6200 Rev A 04-22 Page 3
STEP 1: PREPARE DOOR
1. Mark position of holes on the door per template (see figure 1).
2. Drill all holes marked on the door for the device chassis and top and bottom latch mounting
brackets.
3. Mortise hole for outside trim is required.
NOTE; Any hole drilled from the outside, first needs a pilot hole drilled from the inside
to ensure good alignment.
Figure 1
2-7/16”
Mark Backset
JAMB
2-3/8"
3-7/32"
INSIDE FACE OF DOOR
(40")
Mark of device
CL
3-7/32"
1-15/32"
1/4”
of top and bottom latches
CL
Surface of the door must be flush.
Clear away any raised jutting to allow
the exit device to rest on flat surface of
the door.
40" to finished floor
Standard centerline height of device is 40" above the finished floor.
Prepare door for your specific
device per supplied template.
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011