PROGRAMMING SYSTEM SETUP (Continued)
Keypad Status after Step Completition
Using Duress Codes (Default: OFF)
A) Enter 4 #
B) Enter 0 # to turn OFF
use of Duress Codes
--or –
Enter 1 # to turn ON use of Duress Codes
C) Return to Step 3 or enter to exit programming.
Important Note:
Duress Code Option must be determined and programmed prior to User
Programming!!! You should hear a triple beep after completing step B indicating the use of duress
codes has been successfully reprogrammed. A long steady beep indicates an error (i.e. there may be
individual user codes already programmed into the system. These codes must all be deleted in order
to set duress option to ON.)
Step
A)
B)
Beep
Double
Triple
Red LED
Slow Flash
Slow Flash
Green LED
Slow Flash
Solid
Configuring 2
nd
Relay (Default: Aux 5 sec)
A) Enter 5 #
B) Select one of the following:
External Alarm
I. Enter 1 #
II. Enter the desired Alarm Shunt Output Time (01 - 99 seconds),
followed by #
Internal Alarm
I. Enter 2 #
II. Enter the desired Door Ajar Time in two digits (01-99 seconds),
followed by #
Auxiliary Device
I. Enter 3 #
II. Enter the momentary output time in two digits (01-99 seconds),
followed by #
-- or --
Enter 0 0 to set the auxiliary device for Manual Operation (ON/OFF),
followed by #
Examples: 5 # 1 # 1 5 # Set External Alarm Shunt Option for 15 seconds
5 # 2 # 1 0 # Set Internal Alarm with a 10 second Door Ajar Time
5 # 3 # 0 0 # Set Auxiliary Device with Manual Operation
C) Return to Step 3 or enter to exit programming.
Step
A)
i.
ii.
Beep
Double
Double
Triple
Red LED
Slow Flash
Slow Flash
Slow Flash
Green LED
Slow Flash
Fast Flash
Solid
P:\INSTALLATION INST\ACCESS CONTROL\INST-935.vsd 0505 Page 14
**
**