CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

Set default parameters (first time use)

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter: 

03#  4# 

Set the entry code length to 4 digits

Step 3. Enter:  

21# 5#

Set the main relay activation time for 5 sec.

Step 4. Enter:  

#  

Exit programming mode

**

EXTERNAL CONTROLLER

P:\INSTALLATION INST\Access Controls\INST-921\INST-921P.vsd     Rev D    10-14     Page 2

Assign a user  (PIN only)

Step 1. Enter:  

#9#  123456#    

Enter programming mode (default master code)

Step 2. Enter:  

01#  003# 2580# 2580# 1#    

Assign User 003 with a PIN code of ‘2580’. 

Activate the main relay when entered.   

Step 3. Repeat Step 2 to enter another unique user & PIN or continue to Step 4.

Step 4. Enter:  

#  

Exit programming mode

**

Test your new user

Present your card or enter an authorized PIN code + #. The green indicator should 
illuminate and the main relay should activate, unlocking  the door for 5 seconds.

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
“PROGRAM 
MODE”
INDICATOR

KEYPAD

FRONT

PROX 

Antenna

Assign a user  (Card & PIN only)

Step 1. Enter:  

#9#  123456#    

Enter programming mode (default master code)

Step 2. Enter:  

06#  002# 9876# 9876# 1# (Present card) 

Assign card to User 002 with a

PIN code of ‘9876’. Activate

the main relay when validated.

Step 3. Repeat Step 2 to enter another unique user & card, or continue to Step 4.

Step 4. Enter:  

#  

Exit programming mode.

**

Deleting a  user code

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter:  

02#  002# 002# 

User  2 has been deleted. 

Step 3. Enter:  

#  

Exit programming mode

**

QuickStart  Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the  921P 
EntryCheck™ is in programming mode. Use the option codes to program each function.   After the new data entry is complete for 
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the 
programming has been accepted.  The red indicator will light if any programming data is entered incorrectly or the function is 
rejected. If a red indicator is seen, the entire function (option code + data)  will have to be fully re-entered.  The keypad will remain 
in programming mode until        # is pressed or after 30 seconds of inactivity.

**

Содержание EntryCheck 921P

Страница 1: ...ushbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Страница 2: ...Assign a user Card PIN only Step 1 Enter 9 123456 Enter programming mode default master code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the...

Страница 3: ...upply DTRX POWER 6 5 4 3 2 1 2 1 1 2 3 1 2 3 1 2 3 4 5 6 7 8 MAIN AUX WIRES JP2 POWER LED DTRX JP1 KEYPAD BACK DTRX PIGTAIL USER PROVIDED 6 CONDUCTOR JACKETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU...

Страница 4: ...oller Connect the door switch to the keypad s SENSE terminal E8 and ground terminal Either E1 E4 E5 or E7 If an inhibit switch or timer is going to be used for temporarily disabling the keypad route t...

Страница 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Страница 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Страница 7: ...te Output 3 On time Default 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation...

Страница 8: ...0 14 Page 8 2X Mount at slots MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 4X Mount at holes With supplied screws and hole expansion anchors SURFACE MOUNT STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTI...

Страница 9: ...4X Mount at holes P INSTALLATION INST Access Controls INST 921 INST 921P vsd Rev D 10 14 Page 9 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD POST MOUNT WITH SHROUD 4 4...

Отзывы: