P:\ INST INSTRUCTIONS\ACCESS CONTROLS\INST-918W       Rev A       11-21       Page 2

918W WIRING

See Fig. 3 for an example of a basic door installation.  
The 918W is mounted adjacent to the door.  An electric 
door strike is mounted in the door jamb to release the 
door lock.  A magnetic switch is mounted on top of the 
door jamb for detecting when the door is open.  The 
access host controller is located at a maximum distance 
of 300ft of the keypad reader, depending on the reader 
voltage provided.

Refer to the Fig. 4 or Fig. 5 for wiring details.

To avoid damage to the unit from static discharges, 
mount the faceplate to a good earth grounding point.  
Suggested wiring size is 18 AWG for earth ground.

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

Fig. 3  Basic Door Installation  

 6 wires for    

  KP Reader    

SDC IP Pro™ Single Door Controller 

or 3

rd

 Party Access Control

2 wires for

Door Sensor

2 wires for

Strike Power

918W

Keypad

2 wires for

Remote

Release

Fig. 4 Wiring Harness Connections

Wire Color Designation

RED

+VDC (5‐16V)

BLACK

GND

WHITE

WIEGAND D1

GREEN

WIEGAND D0

ORANGE

GREEN LED CONTROL

YELLOW

BUZZER CONTROL

918W Wiring Harness Connections

Fig. 5 Installation Wiring to IPDCE Single-Door Controller

WIRING 

HARNESS

RED

BLK

WHT
GRN

ORG

YEL

Buzzer

SDC P/N:  

IPDCE or IPDSE

SENSE
CLOCK

DATA

+

12V

0V

RED
GREEN

BEEPER 
LEVEL 
JUMPER
(JP1)

MASTER 
CODE
RESET 
JUMPER
(JP2)

S.S. 
FACEPLATE

Fig. 1 Keypad (Back)

6-PIN WIRING

HARNESS

YELLOW
“PROGRAM”
INDICATOR

KEYPAD

RED/GREEN
POWER/ACCESS
INDICATOR