SDC EA-728 Скачать руководство пользователя страница 5

P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd      Rev A               07-17     Page  5

EA-708 Mortise Key Cylinder Installation:

Adjustable 

Switch

Assembly

Locknut

Faceplate

Key Cylinder

SDC Part# 

CYL-KD

Switch

Mounting

Bracket

ASSEMBLY DETAIL

SOUND DAMPENER

All Exit Alarm Assemblies are shipped with a 
sound dampening cap loose in the box.

Install the unit without the cap for full volume.

Install the unit with the cap as shipped for 
complete dampening.

Install the unit with the center hole punched 
out for partial dampening

triangular

tabs

Ensure that the cam makes 
contact with the center of 
the switch plunger

4.  Complete the wiring connections by carefully routing the 
(2) white & (2) yellow wire leads behind the board.  Terminate 
the (2) yellow wires to Control terminal “A”.  Terminate the (2) 
white wires to Control terminal “B”.  

Or supply compatible 1” to 
1-3/8” standard or 
interchangeable core 
mortise key cylinders (not 
included)

Use tailpiece supplied with 
SDC Part# 

CYL-KD

, or Ilco 

863G-00-10 Standard Cam 
equivalent.

NO

(Reset)

SWITCH WIRING

YEL

WHT

COM

NO

YEL

WHT

COM

(Bypass)

WHT

WHT

YEL

YEL

A

B

CENTER HOLE 

PUNCHED

CENTER HOLE 

AS SHIPPED