P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd Rev A 07-17 Page 5
EA-708 Mortise Key Cylinder Installation:
Adjustable
Switch
Assembly
Locknut
Faceplate
Key Cylinder
SDC Part#
CYL-KD
Switch
Mounting
Bracket
ASSEMBLY DETAIL
SOUND DAMPENER
All Exit Alarm Assemblies are shipped with a
sound dampening cap loose in the box.
Install the unit without the cap for full volume.
Install the unit with the cap as shipped for
complete dampening.
Install the unit with the center hole punched
out for partial dampening
triangular
tabs
Ensure that the cam makes
contact with the center of
the switch plunger
4. Complete the wiring connections by carefully routing the
(2) white & (2) yellow wire leads behind the board. Terminate
the (2) yellow wires to Control terminal “A”. Terminate the (2)
white wires to Control terminal “B”.
Or supply compatible 1” to
1-3/8” standard or
interchangeable core
mortise key cylinders (not
included)
Use tailpiece supplied with
SDC Part#
CYL-KD
, or Ilco
863G-00-10 Standard Cam
equivalent.
NO
(Reset)
SWITCH WIRING
YEL
WHT
COM
NO
YEL
WHT
COM
(Bypass)
WHT
WHT
YEL
YEL
A
B
CENTER HOLE
PUNCHED
CENTER HOLE
AS SHIPPED