background image

The 

EntryCheck

™  924P Indoor/Outdoor Keypad is a surface mount digital 

keyless entry system designed for access control applications.  The backlit 
keys  are bright and, easy-to-read. A heavy cast vandal resistant housing 
design with mounting plate allows the 924P  to be mounted on a  rugged 
surface or on a standard single-gang electrical box.  The control electronics 
are housed in a separate enclosure for added security. This helps to 
prevent unauthorized access to the electronics of the keypad. 

The 924P has a capacity of 500 users. Users can be assigned to use 4 to 6 
digit  PIN codes and or access cards. An authenticated access   can be 
programmed to activate one, or both of the relay outputs. 

The timed  “anti-passback” feature prevents using the same credentials  
twice  before a programmed waiting period has  elapsed.

Two long lasting solid state LED indicators show the status of the system.  
The left bi-color indicator lights red to indicate power, then green when a 
relay is active (e.g., an access grant, etc.).  The right indicator flashes 
yellow to indicate that the keypad is in programming mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low

The 

SENSE 

input can be configured  two ways through programming .  

When configured for “Door Sense”, the input is wired to a normally closed 
door position switch to detect when the door is opened or closed.  Forced 
entry or door ajar situations can then be detected. The “Auto-relock” feature 
can also be used  to  turn off the Main Relay output immediately when the 
door is closed after access has been granted to prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be wired to 

a normally open “service” switch or automatic timer that will disable access 
while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open pushbutton 

to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3 
or Output #4 (programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  This 

signal can be programmed to activate any of the relays or solid state 
outputs  to shunt alarm contacts on the access door/gate  preventing the  
triggering of an alarm when an authorized access occurs.

The 924P 

EntryCheck

™ is powered from a 12-24V AC or DC source. The 

non-volatile EEPROM memory retains  entry codes and programming when 
power is removed.  An internal jumper is provided to reset the master code.  
The Main Relay has a 5 Amp capacity.  The Auxiliary Relay has a 2 Amp 
capacity.  Two solid state outputs, capable of sinking 100 mA to common 
are programmable for alarm shunting, or to signal forced entry, door ajar, 
keypad lockout, request-to-exit, and keypad active conditions.

P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd     Rev C     10-14     Page 1

INSTALLATION INSTRUCTIONS

924P 

EntryCheck 

TM

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: [email protected]

SPECIFICATIONS

Mechanical

Keypad Dim:

1.750" W x 7.3125" H x 1.375" D

(1.4375” wall projection)

Ext. Controller Dim:  7.75" W x 5.75" H x 3.70" D

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

Output Ratings

Main Relay: Form “C” 5 Amps @ 28 Volts max

Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max
Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -22°F to 149°F (-30°C to 65°C)
Humidity: 5% to 95% non-condensing

4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or 
two relays
Disable input
Door sense input
Request-to-exit/enter input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
Control electronics separate from 
keypad for added security.
12V or 24V, AC or DC operation

Keypad programmable
500 user codes
3 User Modes 

PIN or Card
Card Only
Card and PIN

Features

Содержание 924P EntryCheck

Страница 1: ...shbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to...

Страница 2: ...aster code Step 2 Enter 06 002 9876 9876 1 Present card Assign card to User 002 with a PIN code of 9876 Activate the main relay when validated Step 3 Repeat Step 2 to enter another unique user card or...

Страница 3: ...KETED CABLE 100ft MAX RED BLK GRN GRY PINK BLU N C COM N O N C COM N O 1 GROUND C N O N C C N O N C N C DOOR POSITION SWITCH N O REQUEST TO EXIT SWITCH EARTH GROUND CONNECTION AUXILIARY OUTPUTS 100mA...

Страница 4: ...door strike wire to the keypad s PWR terminal Connect a wire between the keypad s PWR terminal and the MAIN RELAY COM terminal Power Choose a location for the DC power supply or AC transformer Connect...

Страница 5: ...rmined by the entry code length setting Leading zeros will have to be entered by the user when entering their code to gain access Erasing a Single User Press 02 User User User The user number to delet...

Страница 6: ...REX input terminates toggle of Main Relay Main Relay On time Default 02 Seconds Sets the length of time the Main Relay activates when triggered Green LED is on when Main Relay is active Press 21 Secon...

Страница 7: ...ault 02 Seconds Sets the length of time Output 3 activates when triggered Press 23 Seconds Seconds Output time in seconds 0 60 99 Toggle Mode Beep Sounds Anti Tamper Activation Default No Selects whet...

Страница 8: ...ols INST 924 INST 924P vsd Rev C 10 14 Page 8 STANDARD WALL MOUNT SINGLE GANG BOX MOUNT OPTIONAL WALL MOUNT 3 413 CONTROLLER HOUSING MULLION MOUNT 1 375 7 3125 1 750 4X Mount at holes With supplied sc...

Отзывы: