FACTORY DEFAULTS

Master Programming Code………..………………….….…...123456  
Entry Code Length……………………………………….……..4 digits
Request-to-exit Output Relay……………………….........Main Relay
Alarm Shunt Output….………………………………….........Disabled
Forced Entry Output……………………………..…………..Output #3
Door Ajar Output…………………………………..………...Output #4
Main Relay On Time………………………………...……..60 Seconds
Auxiliary Relay On Time………………………………...…60 Seconds
Solid State Output #3 On Time………………………..….60 Seconds
Solid State Output #4 On Time…………………………...60 Seconds
Door Sense/Inhibit Input…………………………...……..Door Sense
Keypad Lockout Output………………………………..…….Disabled
Keypad Active Output………………………………..…..…..Disabled
Beeper Sounds When Key Pressed……………………...………Yes
Beeper Sounds During Relay #1………………………..…...…….No
Beeper Sounds During Relay #2……………………………...…...No
Beeper Sounds During Output #3……………………………….....No
Beeper Sounds During Output #4……………………………........No
Keypad Lockout Count……….………......….3 Tries Before Lockout
Anti-Passback Time………………..……...……….No Anti-Passback
Auto-Relock…………………………………...………….………….On

BASIC PROGRAMMING

When the 918 EntryCheck™ is in Programming Mode, both 
indicators will turn off until programming begins.  After a 
programming option number is entered, the yellow indicator will 
blink.  This shows that the 918 is ready to accept the new 
programming data.  After the new data entry is complete, the 
yellow indicator will flash while the data is being stored.  The 
green indicator will light if the data is accepted.  The red indicator 
will light if any programming data is entered incorrectly, and the 
command will have to be fully re-entered.

Entering Programming Mode

The 6-digit Master Programming Code (default = 123456) is used 
to enter Programming Mode.

Press:  # 9 # Master Code

Master Code = the current 6-digit Master Programming Code

Exiting Programming Mode

Press:  

* * 

The red indicator will light after exiting Programming Mode

Note: 

The 918 will automatically exit Programming Mode after 

two minutes of inactivity

Re-entering a Command After a Mistake

If the red indicator lights, signaling an incorrect entry, or an 
incorrect key is pressed during programming, to clear the keypad 
and re-enter the command:

Press:  

9 #  

Setting Entry Code Length

Default: 4 digits

Press: 0 3 # 

Length

#  

Length = 1-6 for entry code length

Note: 

If the Entry Code Length is going to be changed from the factory 

default of 4 digits, make this change first before programming any entry 
codes.

Adding a New Entry Code

Press: 0 1 # 

Code

#  

Code # Relay #

Code

=The new entry code: 1-999999, depending on code length

Relay

=Relay output entry code will activate:

1=Main Relay   2=Auxiliary Relay   3=Both Relays

10=Relay #1, toggled  20=Relay #2, toggled  30=both Relays toggled

12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled

The yellow indicator will flash quickly while the 918 searches its 
memory for available space and duplicate entries.  The green 
indicator will light when the new code is stored.
If the new entry code chosen is already being used for another entry 
code, the red indicator will light.  A new unique code needs to be 
entered.

Note:

Leading zeros (zeros before the code number, i.e.0001) do not need to 

be entered when programming a new code.  The 918 will internally add any 
zeros to fill digits determined by the entry code length setting.  Leading zeros 
will have to be entered by the user when entering their code to gain access.

Erasing a Single Entry Code

Press: 0 2 # 

Code

#  

Code

#  

Code=The entry code to delete

The yellow indicator will flash quickly while the 918 searches its 
memory for the code to erase.  The green indicator will light when 
the code is erased.

Erasing All Entry Codes

WARNING:  PERFORMING THIS COMMAND WILL REMOVE 

ALL ENTRY CODES FROM THE MEMORY

Press: 9 7 # 0 0 0 0 0 0 #  0 0 0 0 0 0 #  

Note: 

The green indicator will light while the memory is being erased.  This 

may take up to 15 seconds.

Changing the 6-Digit Master Programming Code

Press: 9 8 # 

Master Code

Master Code

#  

Master Code=The new 6-digit Master Programming Code

New master code: ____________

PROGRAMMING OPTIONS

There are several 918 EntryCheck™ programming options.  For 
most installations, the factory set default options are sufficient.  
The keypad must be in Programming Mode to make these 
changes.                      

Programming the 918 To Hold the Output

SDC’s EntryCheck™ products have a programmable “Toggle 
Mode” available for each relay and solid-state output. When an 
output is programmed for Toggle Mode, the output alternates from 
OFF to ON or from ON to OFF each time it is activated.  When 
output is toggled on, the green LED flashes until toggled off.

The rules for a toggle output are:

If the output is OFF, it will turn ON and stay on until the next 
activation.
If the output is ON, it will turn OFF and stay off until the next 
activation.

P:\INSTALLATION INST\Access Controls\INST-918\INST-918.vsd     REV A     03-12     Page 4