101-DE/101-KDE Operational Description

The door is  closed  and secured by latching hardware.  The model 101-DE/101-KDE Exit Check controller sends power 
to the magnetic lock or Delayed Egress Panic Device to lock the door in the secured  position. The  integral digital 
display shows the unlock delay time.  

Activation / Alarmed Release :

Activation of the Exit Check’s trigger input  initiates the  15 or 30 second unlock cycle . A pre-activation warning tone is  
sounded during the short nuisance delay period and the integral display starts counting down. To prevent false alarms, 
removing the trigger input activation during the nuisance delay period will  silence the pre-activation warning tone,  reset 
the countdown display and keep the door locked.   

Once the nuisance delay period  has been exceeded, the Exit Check continues  to count down during an irreversible 
door release cycle.  The integral digital countdown display and voice commands continue to inform the person intending 
to exit of the seconds remaining until unlock. An alarm output is  activated  to alert personnel of an unauthorized exit. 
After the 15 or 30 second delay cycle has expired, the Exit Check will remove power to the locking device, releasing  the 
door  and allowing free egress. 

Reset / Relock:

The Exit Check can be manually  reset by authorized personnel by closing the door and entering a code on the integral 
digital keypad, momentarily turning  the optional reset key switch to the reset position or by momentarily activating a N/O 
switch connected to the remote reset  terminals.  

Request to Exit / Authorized  Bypass:

A Request to Exit cycle is initiated by entering an authorized  REX code on the integral digital keypad, momentarily  
turning the optional key switch to the bypass position or momentarily activating a N/O switch connected to the REX 
terminals. The power will be removed  from the locking device  allowing free egress. After the request to exit  cycle has 
expired, the Exit Check will automatically reapply power to the locking device to re-secure the door.

Unlocking the door for extended periods of time (Authorized Bypass mode) is accomplished by entering an Authorized 
Bypass code on the integral keypad, momentarily turning  the  optional key switch to the Bypass position or placing a 
maintained closure across REX  terminals. Releasing the closure across the REX terminals will restart the Request to 
Exit cycle. Entering the Reset code on the integral digital  keypad,  or momentarily turning  optional key switch to the 
Reset position will immediately  reapply power to the locking device to re-secure the door.

P:\INSTALLATION INST\Delayed Egress\INST-101DE_KDE.vsd      Rev E               07-15     Page 2

(BOCA/Chicago)

The 101-DE/101-KDE operation 
complies with BOCA National 
Building Code and the Chicago 
Building Code:  UL Listed, Special 
Locking Arrangements and Auxiliary 
Locks.

Option 

Code 

Delay Release 

Time

Nusiance 

Time

Reset after 

Alarm

Lock Status  on 

Power-Up

Auto/Manual

BD

15 sec

Fixed

0 sec or 1 sec

Selectable

Locked or Unlocked

Selectable

Auto/MAnual

BH

30 sec 

Fixed

0 sec or 1 sec 

Selectable

Locked or Unlocked

Selectable

Auto/Manual

BC

15 sec

Fixed

0 sec 

Fixed

Locked or Unlocked

Selectable

Per BOCA compliance, the Exit Check is manually  reset by authorized personnel after an alarm by closing the door and 
actuating  the integral reset key switch or by momentarily closing a contact connected to the  remote reset terminals. In 
addition, reset  will  be automatically initiated once the door has been opened, then closed and remains closed for 30 
consecutive  seconds. 

(NFPA-101)

The 101-DE/101KDE operation 
complies with the following building 
and fire codes:  NFPA 101; NFPA 1-
UFC; UBC; IBC; IFC; SBC; 
California Building Code.  Listings: 
UL Listed: Special Locking 
Arrangements and Auxiliary Locks; 
California State Fire Marshal 
(CSFM) Listed.

Option 

Code 

Delay Release 

Time

Nusiance 

Time

Reset after 

Alarm

Lock Status  on 

Power-Up

Manual

NA

15 sec or 30 sec

Selectable

1 sec or 2 sec

Selectable

Locked or Unlocked

Selectable

Manual

ND

15 sec 

Fixed

0 sec or 1 sec

Selectable

Locked or Unlocked

Selectable

Manual

NH

30 sec

Fixed

0 sec or 1 sec

Selectable

Locked or Unlocked

Selectable

Manual

15 sec

Fixed

0 sec or 1 sec

Selectable

Unlocked

Fixed

NC

(CBC Compliant)

Содержание 01-DE Exit Check

Страница 1: ...ST Delayed Egress INST 101DE_KDE vsd Rev E 07 15 Page 1 Any suggestions or comments to this instruction or product are welcome Please contact us through our website or email engineer sdcsecurity com A...

Страница 2: ...o re secure the door Unlocking the door for extended periods of time Authorized Bypass mode is accomplished by entering an Authorized Bypass code on the integral keypad momentarily turning the optiona...

Страница 3: ...ture assembly with tray required for proper operation of the trigger switch EMLock Door Mount magnet and armature tray assembly per template ARMATURE HOLDER ARMATURE 1 2 DOOR 1 1 4 SEX NUT 5 16 18 ARM...

Страница 4: ...d PUSHUNTILALARMSOUNDS DOORCANBEOPENEDIN15 SECONDS RECESSED MOUNTING DRY WALL 3 3 4 PUSHUNTILALARMSOUNDS DOORCANBEOPENEDIN15 SECONDS KEY CYLINDER INSTALLATION KDE Model Only 1 Cut hole in dry wall to...

Страница 5: ...E WALL or POST MOUNTING with WEATHER SHROUD 1 Use optional 3 Gang Box inside optional Shroud as a template to drill pilot holes through shroud and into post or wall 2 Mount 3 Gang Box and Shroud to Po...

Страница 6: ...PACKING FOAM BETWEEN WALL AND UNIT TO PREVENT DAMAGE TO FACEPLATE USE 1 1 4 SCREWS SUPPLIED WITH WALL MOUNT FRAME TO HANG UNIT TEMPORARILY FOR WIRING PURPOSES VIEW A A WIRE UNIT AS SHOWN SHOWN WITH NO...

Страница 7: ...7 8 3 4 5 6 7 8 l PAIR OF DOORS 101 DE 101 KDE PWR LOCK RED R NO C TRIG REX RESET C NO C NO C NO To Power Supply WARNING CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL PRIOR TO SELECTING DELAY...

Страница 8: ...lay is counting down with audible alarm voice instructions Once the display reaches 00 the door will unlock 15 14 01 DELAYED EGRESS MODE 00 00 The door is unlocked and has been opened ALARMED UNLOCKED...

Страница 9: ...ess Changing the Master Code User 1 is always used as the Master Code and is required to access keypad programming The Factory Default Master Code is 1234 It is strongly recommended that a new Master...

Страница 10: ...ctions 1581DEV SPST only D Door position sensor indicates door open and door closed Commonly used to verify egress after alarm and exit delay activation Not available with 1581DE 1576DE or 1575DE VI S...

Страница 11: ...ystem 6 Upon power up you must manually reset the lock to activate the IBO input P INSTALLATION INST Delayed Egress INST 101DE_KDE vsd Rev E 07 15 Page 11 Connection to a Infant Patient Monitoring Sys...

Страница 12: ...R Power Supply Power Transfer Hinge or Loop MSB550 PSB560 REX Bar Lock Power RED LED GRN LED LED COM 101 1A or 101 1AK REMOTE ANNUCIATION REMOTE TRIGGER MSB550 PSB560 REX TRIG RESET IBO J4 J6 J1 KEYPA...

Отзывы: