INSTALLATION INSTRUCTIONS

101-DE/101-KDE

Features:

Egress Delay

15 or 30 second exit delay
1 or 2 second nuisance delay

Built-In 3 Function keypad

Alarm and lock reset
1 to 30 second bypass
Sustained bypass
Additional keyswitch optional

Control Inputs

1 to 30 second request-to-exit and bypass  
input with anti-tailgate and jumper 
selectable door prop alarm.
Reset

Built-In Annunciation

Armed mode
Nuisance mode
Irreversible egress mode
Release mode
Digital countdown mode
Field selectable voice notification or tone
Field selectable male voice with security 
message or female voice with safety 
message

Monitoring Outputs

Armed mode
Egress initiation status
Released status

Optional EMLock Outputs

Door position sensor – indicates door 
open and door closed, commonly used to 
verify egress after release.
Magnetic bond sensor – indicates locked 
with full holding force, low holding force, 
unlocked and tampering.

Triggering Options

Egress alarm triggered by door 
movement when used with SDC 
1500DE series EMLocks.
Trigger input from external device 
field selectable (N/O or N/C)

Field selectable automatic or manual 
power up after emergency release or 
power loss.  Use of manual power up 
complies with California Building Code 
(OSHPD) requirements.

Code Compliance

IFC International fire Code
IBC International Building Code
NFPA 101 Life Safety Code
NFPA 1 Uniform Fire Code
California Building Code 

P:\INSTALLATION INST\Delayed Egress\INST-101DE_KDE.vsd      Rev E               07-15     Page 1

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

Application:

When unauthorized egress is initiated SDC 

Exit Check

®

delays egress 

through the door for 15 seconds (or 30 seconds).  Meanwhile, the person 
exiting must wait while personnel or security responds.  The door unlocks 
after 15 seconds have elapsed permitting egress. When powered by a fire 
control supervised power supply, the lock will release immediately in an 
emergency. The integral digital keypad eliminates the need to carry and 
locate keys for reset and bypass functions.

Choice of Mounting

Recessed mounted

(3 gang metal plaster ring included)

Surface mounted with optional 3 gang 
box (DEC-J)
Optional shroud (SHD-J) to be used with 
DEC-J surface box.

Exit Check

®

applications include:

Restricting the egress of wandering patients for their own safety.
HUGS

®

Infant Protection System compatibility

Restricting the egress of commercial center patrons for security application needs.
Controlling pedestrian traffic in transportation facilities, including airport jetways and tarmacs
Reducing  Shoplifting and Employee Theft 

Display Modes

Door armed and locked.

Alarm countdown has ended,
door is unlocked and alarm sounding
until reset.

Door unlocked and alarm is shunted
(REX or Bypass)

Door has been opened after REX,
Bypass or Alarm.

15

00

- -

- -

- -

- -

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: [email protected]

Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display

Содержание 01-DE Exit Check

Страница 1: ...ST Delayed Egress INST 101DE_KDE vsd Rev E 07 15 Page 1 Any suggestions or comments to this instruction or product are welcome Please contact us through our website or email engineer sdcsecurity com A...

Страница 2: ...o re secure the door Unlocking the door for extended periods of time Authorized Bypass mode is accomplished by entering an Authorized Bypass code on the integral keypad momentarily turning the optiona...

Страница 3: ...ture assembly with tray required for proper operation of the trigger switch EMLock Door Mount magnet and armature tray assembly per template ARMATURE HOLDER ARMATURE 1 2 DOOR 1 1 4 SEX NUT 5 16 18 ARM...

Страница 4: ...d PUSHUNTILALARMSOUNDS DOORCANBEOPENEDIN15 SECONDS RECESSED MOUNTING DRY WALL 3 3 4 PUSHUNTILALARMSOUNDS DOORCANBEOPENEDIN15 SECONDS KEY CYLINDER INSTALLATION KDE Model Only 1 Cut hole in dry wall to...

Страница 5: ...E WALL or POST MOUNTING with WEATHER SHROUD 1 Use optional 3 Gang Box inside optional Shroud as a template to drill pilot holes through shroud and into post or wall 2 Mount 3 Gang Box and Shroud to Po...

Страница 6: ...PACKING FOAM BETWEEN WALL AND UNIT TO PREVENT DAMAGE TO FACEPLATE USE 1 1 4 SCREWS SUPPLIED WITH WALL MOUNT FRAME TO HANG UNIT TEMPORARILY FOR WIRING PURPOSES VIEW A A WIRE UNIT AS SHOWN SHOWN WITH NO...

Страница 7: ...7 8 3 4 5 6 7 8 l PAIR OF DOORS 101 DE 101 KDE PWR LOCK RED R NO C TRIG REX RESET C NO C NO C NO To Power Supply WARNING CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL PRIOR TO SELECTING DELAY...

Страница 8: ...lay is counting down with audible alarm voice instructions Once the display reaches 00 the door will unlock 15 14 01 DELAYED EGRESS MODE 00 00 The door is unlocked and has been opened ALARMED UNLOCKED...

Страница 9: ...ess Changing the Master Code User 1 is always used as the Master Code and is required to access keypad programming The Factory Default Master Code is 1234 It is strongly recommended that a new Master...

Страница 10: ...ctions 1581DEV SPST only D Door position sensor indicates door open and door closed Commonly used to verify egress after alarm and exit delay activation Not available with 1581DE 1576DE or 1575DE VI S...

Страница 11: ...ystem 6 Upon power up you must manually reset the lock to activate the IBO input P INSTALLATION INST Delayed Egress INST 101DE_KDE vsd Rev E 07 15 Page 11 Connection to a Infant Patient Monitoring Sys...

Страница 12: ...R Power Supply Power Transfer Hinge or Loop MSB550 PSB560 REX Bar Lock Power RED LED GRN LED LED COM 101 1A or 101 1AK REMOTE ANNUCIATION REMOTE TRIGGER MSB550 PSB560 REX TRIG RESET IBO J4 J6 J1 KEYPA...

Отзывы: