SD GlucoNavii® Link0.3 NFC BLOOD GLUCOSE MONITORING SYSTEM

 

healthcare professional. Never ignore symptoms or make 
significant  changes  to  your  diabetes  control  program 
without speaking to your healthcare professional. 

t

Consult your physician to determine if it is appropriate for 
your child to be taught how to use the meter system or 
any other medical products.

2.     Special Information for Healthcare Providers and 

Caregivers

t

 Do  not  use  this  device  to  measure  blood  glucose  in 
people  who  are  experiencing  cardiovascular  collapse 
(severe shock) or decreased peripheral blood flow. 

t

Hematocrit: 

A  hematocrit  (percentage  of  your  blood 

that is red blood cells) that is over 60% or below 20%  can 
cause false results. 

3.  Indication for use (Purpose of the devices)

Your new SD GlucoNavii® Link0.3 NFC meter and accessories 
work together to measure the amount of glucose (sugar) 
in your blood.  

Your SD GlucoNavii® Link0.3 NFC blood glucose monitoring 
system  is  indicated  for  monitoring  glucose  in  fresh 
capillary  whole  blood  or  fresh  venous  blood.  Testing 
is  done  outside  the  body.  (

in  vitro

  diagnostic  use)  This 

system is indicated for home (over-the-counter or OTC) by 
person with diabetes, or in clinical settings by healthcare 
professionals,  as  an  aid  to  monitor  the  effectiveness  of 
diabetes control. This system should not be used for the 
diagnosis of diabetes.

The SD GlucoNavii® Link0.3 NFC blood glucose monitoring 
system is suitable for self-testing.

4.  Product Description and the Principle of the use

SD  GlucoNavii®  Link0.3  test  strip  is  designed  with  an 
electrode  that  measures  glucose  levels.  Glucose  in  the 
blood  sample  mixes  with  reagent  on  the  test  strip  that 

n“œŠ–uˆGs•’WUZGumj†|šŒ™G”ˆ•œˆ“†lu†YWXZW[X^†YU•‹‹GGG]

YWXZTW[TX^GGG㝘䟸G\aXYa[X

Содержание GlucoNavii Link0.3 NFC

Страница 1: ...Link 0 3 NFC Link 0 3 NFC Mentor NFC Mentor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor tor NF NFC Link0 3 NFC FCC ID RPJ01GM14 0168 0123...

Страница 2: ...it www sdbiosensor com for diabetes management tools and product demonstrations Please refer to the instructions with following symbols in this User Instruction Guide To identify conditions or practic...

Страница 3: ...6 SD GlucoNavii Link0 3 NFC Meter 7 SD GlucoNavii Link0 3 NFC 8 SD GlucoNavii Link0 3 NFC Accessories 9 Changing the Battery 10 Meter Set up 11 Using SD GlucoNavii Link0 3 NFC Test Strips Chapter 2 C...

Страница 4: ...to a computer Chapter 6 Maintenance and Troubleshooting 1 Performing a SD Glucose check strip 2 Cleaning the meter 3 Maintenance Testing and Transportation 4 Cleaning the Lancing Device 5 Screen Mess...

Страница 5: ...m your fingertip palm upper arm or forearm or fresh venous blood t Only use SD GlucoNavii Link0 3 test strips Other test strips will give inaccurate results or E 1 error message t Do not use the SD Gl...

Страница 6: ...his may require immediate treatment according to your healthcare professional s recommenda tions Although this result could be due to a test error it is safer to treat first and then repeat the test t...

Страница 7: ...se of the devices YournewSDGlucoNavii Link0 3NFCmeterandaccessories work together to measure the amount of glucose sugar in your blood Your SD GlucoNavii Link0 3 NFC blood glucose monitoring system is...

Страница 8: ...ip through capillary action When the chamber is full SD GlucoNavii Link0 3 NFC meter start to measure the blood glucose level It is a simple and practical system for the daily monitoring of your blood...

Страница 9: ...w Buttons Use for meter setup and review of memory moving to the right and left ON OFF Button Press to turn meter ON or OFF Test Strip Slot Insert test strip here Battery Cover Remove cover to change...

Страница 10: ...etting Indicates beep setting Warns when the battery is low or must be replaced Indicates if environmental temperature is exceeded during testing Indicates post meal or pre meal Testing date Indicates...

Страница 11: ...e average result Test strip Tell you when to apply the sample and indicates if you select whole blood for blood reference type Indicates a control solution test result Indicates alarm setting Indicate...

Страница 12: ...into the meter in either Strip Stand by Display or turning off the below will be displayed automatically to show the appropriate test result after applying blood sample And if you pull off the test s...

Страница 13: ...Strip SD GlucoNavii Link0 3 NFC System measures the amount of glucose in whole blood Blood is applied in the Yellow Window TOP EDGE of SD GlucoNavii Link0 3 Test Strip and is automatically drawn into...

Страница 14: ...oNavii control solution NFC Reader Writer 8 SD GlucoNavii Link0 3 NFC Accessories 1 2 Lancing Device Cap Comfort dial with puncture depth selection Arming Knob Release Button Check Strip Lancet SD Glu...

Страница 15: ...n the mesh pocket of your carrying case Battery life will vary depending on usage so always keep a spare on hand The meter saves battery power by automatically turning off after 1 minute without inser...

Страница 16: ...ou STEP 3 Snap battery cover back in place STEP 4 Push the ON OFF button or insert a strip to start testing After inserting or replacing the battery confirm that the time and date are set correctly If...

Страница 17: ...appear the first step of the setting mode 2 Set the beep mode on or off by pressing either the left or the right button and then selecting the preferred feature by pressing the ON OFF button If you se...

Страница 18: ...ther the left or the right button and then selecting the preferred feature by pressing the ON OFF button t You can set the meter to let you know when your result indicates a possible low blood glucose...

Страница 19: ...the third step of the setting mode Set the correct year by pressing either the left or the right button and then select the correct year by pressing the ON OFF button Your new meter comes with a prese...

Страница 20: ...r can display the month and day in either a Month Day m d format or a Day Month d m format Set the preferred format on the display by pressing either the left or the right button and select by pressin...

Страница 21: ...t Set the preferred format on the display by pressing either the left or the right button and select by pressing the ON OFF button 2 Next will appear the setting display for time format Set the correc...

Страница 22: ...al alarm function to remind you to test your blood glucose after meal 1 After day and time setting the display for setting the post meal alarm will appear the fourth of setting mode 2 Set the post mea...

Страница 23: ...test your blood glucose after meal for 1mimute t If you perform the pre meal test while the post meal alarm setting is on then the post meal mark will appear automatically on your LCD when you test w...

Страница 24: ...the fifth of setting mode 2 Set the first alarm on or off by pressing either the left or the right button and then select the preferred feature by pressing the ON OFF button t If you select the alarm...

Страница 25: ...the preferred feature by pressing the ON OFF button 4 If you finish setting the first alarm next will appear the second alarm setting mode Set the alarm with the same way as above 2 3 5 You can set th...

Страница 26: ...st test result when inserting the strip into the meter You can check your latest test result before testing 1 After alarm setting display the Data review setting mode 2 Set the data review function by...

Страница 27: ...within three minutes after you take it out of the container t Store test strip containers in a cool dry place at 2 32 C 36 90 F Keep away from direct sunlight and heat Do not refrigerate test strips t...

Страница 28: ...or single use only Never reuse a test strip that has had either blood or control solution applied to it t Avoid getting dirt food or liquids on the test strip With clean dry hands you may touch the te...

Страница 29: ...think your test strips have been damaged t Your test strips were stored in extreme temperatures and or humidity t You want to check the meter and test strips t You dropped the meter t Your test resul...

Страница 30: ...formation how to obtain SD Glucose control solution call at 82 31 300 0400 t Do not swallow SD Glucose control solution it is not for human consumption t Do not apply SD Glucose control solution to th...

Страница 31: ...solution in Blood Stand by Display If you don t want a control solution test press the left button again 2 Shake the control solution container and discard the first drop of solution Gently squeeze t...

Страница 32: ...orking properly Repeat the control solution test 5 Remove the used test strip for control solution from the meter and discard it mg d L mmo l L Link0 3 NFC NOTE The control solution range printed on t...

Страница 33: ...Have the test strips and or control solution expired Make sure that test strips and control solutions are not past expiration date This date is shown the container bottle Make sure the expiration dat...

Страница 34: ...ly at 2 32 C 36 90 F Was the bottle cap replaced immediately after removing a test strip If not retest with a new container of test strips Is the meter damaged Does it show an error message If yes con...

Страница 35: ...and push down firmly until it is fully seated Twist the lancet protective disk until it separates from the lancet 3 Replace the cap and turn it clockwise until it is snug Adjust the puncture depth se...

Страница 36: ...be used once Do not share used lancets with another person To prevent possible infection a used lancet should not be touched by another person t Used lancets in the regular trash can be dangerous We r...