Page 8 -  VisionGuard 6000

Remote Arming

The system monitors 6 independent areas (

zones

) while armed: doors, hood, trunk, shock sensor, optional

sensor input, and the network port for future expansion.
To Arm the System:

1.  Turn off the ignition.

2.  Press Button 1.

· The siren will chirp once.*

· The doors will lock.

· The parking lights will flash once.

· The LED will turn on red, to indicate the starter defeat is activate.

3.  10 seconds after Arming:

·  The LED will start blinking to indicate that the doors, hood, trunk and sensor inputs are being

monitored.

* During Arming, if the system detects a bad sensor or an open zone, the system will chirp 4 additional

times and ignore that input, but keep all other areas protected. 

Once Armed, the alarm will trigger when any of the following occurs:

·

The doors are opened.

·

The hood or trunk is opened.

·

The shock sensor detects an impact to the vehicle.

·

An optional sensor is disturbed.

When the alarm triggers, the siren will sound, the horn will honk, and the parking lights will flash.  If

the system is triggered by the doors, hood, or trunk, the system will alarm for 45 seconds.  If triggered

by the sensor inputs, the system will alarm for 30 seconds. 
In the event the alarm is triggered and remains triggered continuously by the same sensor or input

during a single arming cycle, that sensor or input will be automatically bypassed until the next time

the system is armed.  
If the Shock Sensor detects a light impact to the vehicle the siren will chirp 5 times as a warning

indication.

Remote Disarming

To Disarm the System:

Press Button 1.

· The siren will chirp twice.*

· The doors will unlock.

· The parking lights will flash twice.

· The dome light will turn on.

· The LED will turn off.

* During Disarming, if the system was triggered while away from the vehicle, the siren will chirp 3 times, the parking

lights will flash 3 times, and the LED will flash to indicate triggered zone.  See 

Tamper Alert

for zone listing.

System  Operation

Содержание VISIONGUARD 6000

Страница 1: ...VISIONGUARD 6000 VEHICLE SECURITY SYSTEM WITH BUILT IN CAMERA AND A REMOTE START PRODUCT MANUAL...

Страница 2: ...ill be a maximum service charge of 25 00 per calendar year if required for repair and or replacement of any defective parts A copy of the original purchase receipt must accompany any products returned...

Страница 3: ...t Mode Page 13 Turbo Timer Feature Page 13 Manual Transmission Remote Starting Page 13 5 Extended Features Page 14 Ignition Door Locking Page 14 Ignition Door Unlocking Page 14 Dome Light Activation P...

Страница 4: ......

Страница 5: ...sed System Contents Main Unit with built in ScyNet Network Interface Port Two Way Full Color Picture Ready LCD Remote Transmitter Camera Remote Transmitter Reseiver One Way 5 Button Random Code Remote...

Страница 6: ...essed Button 4 Activates the Remote Start feature Button 5 is the Page Shift button Each time the Shift Button is pressed the LED on the transmitter will illuminate and the transmitter functions will...

Страница 7: ...transmitter If all four transmitters are to be used with both cars program transmitters A and B into the first vehicle in the manner described above Program transmitters C and D by pressing the Shift...

Страница 8: ...hen pressed together for 2 seconds Activates the Auxiliary 1 output normally used for trunk release Button 4 is the Confirmation button Quickly pressing button 4 will activate the LCD display s backli...

Страница 9: ...equire replacement in time Depending on the amount of use the battery may last up to six months before it needs replacement When the battery needs replacing the system s operating range will decrease...

Страница 10: ...Page 6 VisionGuard 6000 Camera Features...

Страница 11: ...VisionGuard 6000 Page 7...

Страница 12: ...le An optional sensor is disturbed When the alarm triggers the siren will sound the horn will honk and the parking lights will flash If the system is triggered by the doors hood or trunk the system wi...

Страница 13: ...be bypassed when the system is Armed or Disarmed silently Passive Arming When programmed for the optional Passive Arming feature the system arms itself automatically each time the ignition is turned o...

Страница 14: ...door using the key 2 Enter the vehicle The system will trigger and the siren will sound 3 Turn ignition key on 4 Press and hold the override switch for 10 seconds The system will disarm 5 The vehicle...

Страница 15: ...disarmed With the Automatic Rearming feature enabled the alarm will automatically rearm 30 seconds after disarming If the optional Passive Door Locking feature is enabled the doors will also lock whe...

Страница 16: ...he Quick Stop Feature allows you exit the vehicle while keeping the engine running for quick stops To leave the vehicle running 2 While engine running push Remote Start button on the Remote Transmitte...

Страница 17: ...transmitter sidelights will flash twice indicating Manual Start Mode is enabled turn off the Ignition switch the engine will remain running Open and close the door the system will shut the engine Off...

Страница 18: ...ine start power window activation power sunroof control auxiliary lighting audio video system control and more The Pulsed operation setting allows an output to activate as long as the button is held T...

Страница 19: ...er the mounting locations for all visible components including the LED and Override switch 7 Verify with the owner the optional features of the VisionGuard 6000 and the features that must be programme...

Страница 20: ...e Siren Choose a siren mounting location that is away from heat sources such as exhaust manifolds and where it cannot be easily accessed from underneath the vehicle Be sure to face the siren downward...

Страница 21: ...oes not provide satisfactory operation Pin 3 WHITE RED WIRE Auxiliary 2 Output 500 mA Connect to a relay or module for an optional feature such as power window activation etc the output may be program...

Страница 22: ...e White wire to the circuit that shows 12V or ground only when the parking lights are on and set the internal parking light relay jumper to the proper polarity For parking light circuits exceeding 10...

Страница 23: ...olarity jumper will be visible next to the parking light relay Set the jumper for the correct polarity output as described below then reassembly the main unit case Parking Light Output Selects the pol...

Страница 24: ...ramming 2 Press Transmitter Button 3 The siren will chirp 6 times indicating that the reset signal was received All System Programming parameters are now set to factory default settings The Valet Mode...

Страница 25: ...to Rearming Mode Disabled Enabled 3 Arming Chirps Siren Chirps En Silent Siren Horn Chirps En 4 Ignition Door Locking On Off Set Override Code 5 Ignition Door Unlocking Unlock All Unlock Driver Only O...

Страница 26: ...xiliary 1 When selected activating the Auxiliary 1 output usually used to open the trunk will disarm the alarm 15 Start in Valet Mode Selects whether or not the vehicle can remote start while in the v...

Страница 27: ...to trigger a relay for Ignition 3 24 Turbo Timer When enabled if the emergency brake has been applied Ignition power will be kept On for a predetermined time 2min Factory Default from the application...

Страница 28: ...POSITIVE HORN WIRE 12V Brown White HORN OUTPUT TO NEGATIVE HORN WIRE 12V Brown White HORN OUTPUT Positive Horn Honk Negative Horn Honk Blue Yellow Wire GLOW PLUG INPUT Yellow Wire IGNITION GLOW PLUG...

Страница 29: ...Trigger Reverse Polarity Vacuum Adding Actuators Follow the diagrams below for connecting basic door lock systems For Two Stage door lock systems separately unlocks driver and passenger doors see foll...

Страница 30: ...Positive Trigger The VisionGuard 6000 is equipped with a dedicated Passenger Unlock output allowing Two Stage Door Lock operation When connected as shown below disarming the system will unlock only th...

Страница 31: ...VisionGuard 6000 Page 27 Two Stage Door Lock Diagrams cont d Two Stage Reverse Polarity Two Stage Adding Actuators...

Страница 32: ...es with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interfe...

Страница 33: ...age 29 Starter Diagnostics Starter doesn t start and Side Lights flash 3 Times Engine RPM not detected Hood Trigger is active 4 Times Brake Trigger is active 5 Times Unit is in Valet service mode and...

Страница 34: ...Page 30 VisionGuard 6000...

Страница 35: ...VisionGuard 6000 Page 31...

Страница 36: ...ow Ignition Input Blue Yellow Glow plug wait to start Input Blue White Passenger Unlock Output 500mA Blue Orange Remote Start Output 500mA Black Ground Red 12V Battery Input 3 Violet Door Trigger Inpu...

Отзывы: