background image

10.

Ignore Open Door Report.

Bypasses the open zone warning chirps for vehicles equipped with a

residual dome light circuit that remains on for a period of time after closing the door.

11.

Horn Chirps with Arm & Disarm / Anti-Carjack with Valet Reset. 

This dual program branch

activates the horn chirps during Arming and Disarming, and activates one of two Anti-Carjacking

options. 
Horn Chirps. When selected, the horn will provide the arm and disarm indications, allowing the siren

installation to be skipped.  
Anti-Carjacking w/ Valet Reset. When selected, the Anti-Carjacking feature will be enabled, and

pressing the valet switch will reset the Anti-Carjacking feature when triggered.
Note: Disabling either feature this branch with Button 1 will turn off both features.  If either feature

was enabled prior to pressing Button 1, it must be re-enabled or it will remain disabled. 

12.

Horn Output / Anti-Carjack with Hands-Free Operation.* 

This dual program branch selects the

operation of the horn output, and activates the second Anti-Carjacking option. 
Horn Chirps. When selected, the horn will provide the arm and disarm indications, allowing the siren

installation to be skipped.  
Anti-Carjacking w/ Hands-Free Operation.* When selected, the Anti-Carjacking feature will be enabled

for operation with the optional Hand-Free transmitter.  Moving the Hands-Free transmitter out of range

of the vehicle will activate the Anti-Carjacking feature, and moving the transmitter back in range will

reset the Anti-Carjacking feature when triggered.
Note: Disabling either feature this branch with Button 1 will turn off both features.  If either feature

was enabled prior to pressing Button 1, it must be re-enabled or it will remain disabled. 
*Requires the optional Hands-Free transmitter for this Anti-Carjacking feature to operate.

13.

Aux 2 Auto Activate with Arm.

When selected, the Auxiliary 2 output will activate when the system

is armed.  This feature can be used to roll-up windows, close sunroofs, activate accessories, etc. 

14.

Auxiliary 1 Mode.

Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.  

Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is

pressed.  If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains

on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be

programmed to output for 1 second up to 255 seconds.  

15.

Auxiliary 2 Mode.

Selects from Momentary, Timed, or Latched operation for Auxiliary 2.  

16.

Auxiliary 3 Mode.

Selects from Momentary, Timed, or Latched operation for Auxiliary 3.  

17.

Disarm with Auxiliary 1

. When selected, activating the Auxiliary 1 output (usually used to open the

trunk) will disarm the alarm.

BRANCHES 18-21 ARE RESERVED FOR THE PROGRAMMING OF SCYNET NETWORK ACCESSORIES.

CONNECTION OF OPTIONAL ACCESSORIES IS REQUIRE TO USE ANY OF THESE FEATURES.

Page 18 -  Galaxy 3000 Plus

Содержание Galaxy 3000Plus Series

Страница 1: ...3 30 00 00 0P PL LU US S S SE ER RI IE ES S VEHICLE SECURITY SYSTEM PRODUCT MANUAL...

Страница 2: ......

Страница 3: ...tputs Page 8 Disarm with Auxiliary Function Page 8 Remote Sensor Disable Page 9 ScyNet Network Remote Car Start Module Page 9 Optional Hands Free Transmitter Page 9 5 System Installation Page 11 Mount...

Страница 4: ......

Страница 5: ...tion of a completely personalized security and convenience system by offering many optional features such as May require additional parts and or labor see store for details Galaxy 3000 Plus Page 1 Sec...

Страница 6: ...output will remain on for as long as the button is pressed Button 5 is the Page Shift button The Page Shift button will change the function of Buttons 1 through 4 each time it is pressed allowing acc...

Страница 7: ...program transmitters A and B into the first vehicle in the manner described above Program transmitters C and D by pressing the Shift button twice before performing steps 3 and 4 above When finished pr...

Страница 8: ...e An optional sensor is disturbed When the alarm triggers the siren will sound the horn will honk and the parking lights will flash If the system is triggered by the doors hood or trunk the system wil...

Страница 9: ...ed when the system is Armed or Disarmed silently Passive Arming When programmed for the optional Passive Arming feature the system arms itself automatically each time the ignition is turned off and al...

Страница 10: ...er the vehicle The system will trigger and the siren will sound 3 Turn ignition key on 4 Press and hold the override switch for 10 seconds The system will disarm 5 The vehicle will now be able to star...

Страница 11: ...he Automatic Rearming feature enabled the alarm will automatically rearm 30 seconds after disarming If the optional Passive Door Locking feature is enabled the doors will also lock when the system rea...

Страница 12: ...ion and used to add a number of optional features such as power trunk release remote engine start power window activation power sunroof control auxiliary lighting audio video system control and more T...

Страница 13: ...to the action of the car starting or the vibration of the engine The doors hood and trunk however remain protected Optional Hands Free Transmitter Hands Free operation When the optional Hands Free tra...

Страница 14: ...Page 10 Galaxy 3000 Plus...

Страница 15: ...d perform a function test of all vehicle systems before and after the installation 6 Always use a Volt Ohm meter for testing vehicle circuits Never use a test light 7 Always look before drilling any h...

Страница 16: ...unting location that is away from heat sources such as exhaust manifolds and where it cannot be easily accessed from underneath the vehicle Be sure to face the siren downward to prevent the collection...

Страница 17: ...y jumper to the proper polarity For parking light circuits exceeding 10 amps a relay is required For vehicle s with independent left and right parking light circuits diodes must be installed to keep t...

Страница 18: ...module PDLM 3 BLUE WIRE negative unlock output 500mA and positive lock output 250mA RED WIRE constant 12V low current output for relay modules or inverters 100mA relay trigger only Do NOT use as a po...

Страница 19: ...rs for the correct polarity output as described below then reassembly the main unit case Parking Light Output Selects the polarity for the output of the on board Parking Light relay Left Pin Center Pi...

Страница 20: ...System Programming parameters are now set to factory default settings The Valet Mode is off The Disarm Code is 1 3 Turn off ignition Programmable System Options The following is a description of the...

Страница 21: ...ssive Arming Entry Delay When selected the siren will chirp for 10 seconds before sounding if a door is opened The system may be disarmed by simply turning on the ignition when programmed for this fea...

Страница 22: ...e Anti Carjacking feature when triggered Note Disabling either feature this branch with Button 1 will turn off both features If either feature was enabled prior to pressing Button 1 it must be re enab...

Страница 23: ...the ambient temperature drops below a preset point the engine will automatically start and run for the preset time to avoid engine freezing Auto Low Voltage Starting When the vehicle s battery voltage...

Страница 24: ...ositive Trigger Reverse Polarity Vacuum Adding Actuators Follow the diagrams below for connecting basic door lock systems For Two Stage door lock systems separately unlocks driver and passenger doors...

Страница 25: ...ger Two Stage Positive Trigger The Galaxy 3000 Plus is equipped with a dedicated Passenger Unlock output allowing Two Stage Door Lock operation When connected as shown below disarming the system will...

Страница 26: ...Page 22 Galaxy 3000 Plus Two S Stage D Door L Lock D Diagrams c cont d Two Stage Reverse Polarity Two Stage Adding Actuators...

Страница 27: ...s with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interfer...

Страница 28: ...ScyTek Electronics 11627 Cantara Street Unit B North Hollywood CA 91605 ScyTek Electronics 2002 Galaxy 3000 Plus r1 9 02 Wiring D Diagram...