![SCW The ECON Series Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/scw/the-econ-series/the-econ-series_user-manual_1220137108.webp)
108
Please refer to the following sheet for detailed information.
Parameter Function
Event
Type
There are three types: Motion detection/video loss/Camera Masking.
Channel
Select channel name from the dropdown list.
Enable
You need to draw a circle to enable motion detection function.
Sensitivity There are six levels. The sixth level has the highest sensitivity.
Region
There are six levels. The sixth level has the highest sensitivity.
Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown as in
X469H469H469H
Figure
7-41
X
. There are PAL 22X18/NTSC 22X15 zones. Right click mouse
you can go to full-screen display mode. Do remember clicking OK
button to save your motion detection zone setup.
Period
Motion detection function becomes activated in the specified
periods.
There are six periods in one day. Please draw a circle to enable
corresponding period.
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
Click OK button, system goes back to motion detection interface;
please click save button to exit.
Anti-dither System only memorizes one event during the anti-dither period. The
value ranges from 0s to 15s.
Normal
out
There is 2-channel alarm output.
Corresponding to motion detection alarm output port(multiple
choices)
Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
alarm occurs.
Alarm
latch
System can delay the alarm output for specified time after alarm ended.
The value ranges from 10s to 300s.
Alarm
upload
System can upload the alarm signal to the centre (Including alarm
centre.
Record
channel
System auto activates motion detection channel (multiple choices) to
record once alarm occurs (working with motion detection function).
Please note you need to go to Chapter 4.4 Schedule to set motion
detection record period and go to chapter 4.2 Manual Record to set
current period as auto record.
Record
latch
System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
If you enabled this function, System can send out email to alert you
when alarm occurs and ends.
Tour
Display the selected video in local monitor window.
Tour interval and tour mode are set in DVR local menu (chapter
5.3.9 Display )
Содержание The ECON Series
Страница 1: ...The ECON Series DVR User s Manual 866 414 2553...
Страница 44: ...44 Figure 4 24 Figure 4 25 Figure 4 26 Figure 4 27...
Страница 81: ...81 Figure 6 11...
Страница 135: ...135 Samsung HA101UJ CE 1T SATA...
Страница 138: ...138 SANGSUNG LCD T240 24 inch DELL LCD E170Sc 17 inch BENQ LCD G2219HD 19 inch LG LCD W194ST 19 inch...