Scubatech TecLINE R2 TEC Скачать руководство пользователя страница 2

 

Table of contents:

 

1.  Introduction 

2.  Important warnings 

3.  Design and basic technical data 

4.  Intended use 

5.  Using with nitrox mixture and oxygen 

6.  Using in cold water 

7.  Preparing for use 

8.  The use during diving  

9.  The use after diving, maintenance and storage 

10. Warranty 

11. Manufacturer information 

12. Notes 

 

 
 
 

 
 
 
 
 
 
 
 
 

Copyright information 
 

These  instructions  are  protected  by  copyright.  All  rights  reserved.  Copying, 
reproduction,  translation  or  saving  in  any  electronic  medium  in  whole  or  in  part 
without a written consent of Scubatech is forbidden. 
 
 

Demand Regulator User Manual 

 

Series models – 

R2 TEC, R2 TEC O2, R2 TEC INT, R4 TEC, R4 TEC O2, R 4 TEC INT 

   R5 TEC, V1 ICE, V1 ICE INT, V2 ICE, TEC1, TEC1 O2, TEC1 OCTO 

   TEC2, TEC2 O2, TEC2 OCTO

                 

             

 

©2018 Scubatech Ltd. 

Содержание TecLINE R2 TEC

Страница 1: ...1 SCUBATECH User Manual Demand regulators Range of models R2 TEC R2 TEC O2 R2 TEC INT R4 TEC R4 TEC O2 R4 TEC INT R5 TEC V1 ICE V1 ICE INT V2 TEC1 TEC1 O2 TEC1 OCTO TEC2 TEC2 O2 TEC2 OCTO Issue 2018 2 ...

Страница 2: ...anty 11 Manufacturer information 12 Notes Copyright information These instructions are protected by copyright All rights reserved Copying reproduction translation or saving in any electronic medium in whole or in part without a written consent of Scubatech is forbidden Demand Regulator User Manual Series models R2 TEC R2 TEC O2 R2 TEC INT R4 TEC R4 TEC O2 R 4 TEC INT R5 TEC V1 ICE V1 ICE INT V2 IC...

Страница 3: ...ure the best efficiency and service life of this regulator The manufacturer believes that Scubatech demand regulators utility values will make you very satisfied and you will enjoy diving even more SCUBATECH shall not be liable for damages caused by non compliance with the instructions contained in this manual 2 Important warnings CAUTION Diving is a potentially hazardous activity The demand regul...

Страница 4: ...ompliant with current requirements applicable in the country where you intend to use them CAUTION Scubatech demand regulators may be supplied only with the air compliant with the requirements of the standard PN EN 12021 If moisture accumulates in the diving cylinder it may cause possible cylinder corrosion as well as freezing and malfunctioning of the regulator when diving at low temperatures belo...

Страница 5: ...ng environment of the high pressure valve and other valve components against external conditions This solution allows for using the valve in extreme conditions and the regulator is also designed for use by advanced divers The main task of the first pressure reduction stages of demand regulators is to reduce pressure in a diving cylinder twinset to the pressure value that corresponds to the total p...

Страница 6: ...g is easier when the knob is twisted off as it requires less strength to take a breath Adjustment is smooth and you can set the knob in the position that suits you best When storing a diving regulator equipped with a breathing resistance adjustment knob the knob should be set in an open position which prevents against damage of the seat Figure 2 The second stages of pressure reduction of demand re...

Страница 7: ... out by a qualified instructor CAUTION The maximum operating depth and the time of exposure to nitrox mixtures depend on oxygen concentration in the used mixture High oxygen concentration reduces the use of mixtures with standard diving equipment and it requires application of materials and procedures that differ from those required by a user of standard compressed air Using demand regulators with...

Страница 8: ...e or diving regulator is high The usual effects include a constant outflow of breathing gases and their quicker loss as a result The lower the ambient temperature is the higher the risk of the above described situation is Demand regulators operating at low temperatures must be properly protected Isolating a water chamber in a pressure reducing valve from the environment with the use of an antifree...

Страница 9: ...onnections and a mouthpiece are fastened properly test for tightness under negative pressure in the following way o insert the mouthpiece of the second staged demand regulator to your mouth o clog the air inlet to the first staged demand regulator o take a breath through the second staged demand regulator o the demand regulators are tight only if taking a breath is impossible IMPORTANT Before scre...

Страница 10: ...ng regulator during exhalation Except for the situation when being underwater a diver looks at the surface and exhales at the same time whenever you take the diving regulator out of your mouth and then reinsert it first exhale or push the diving regulator s inflate button Otherwise you can choke on water 9 The use after diving maintenance and storage Once diving is finished you must take the divin...

Страница 11: ...ticular against impacts avoid crushes that deform the mouthpiece and other flexible components of the demand regulator the demand regulator s parts that are subject to ageing should be replaced every year irrespective of the frequency of use when storing a diving regulator equipped with a breathing resistance adjustment knob the knob should be set in an open position which prevents against packing...

Страница 12: ...of annual inspections should be always presented Scubatech guarantees to the original buyer that its product is free of any defects in materials or workmanship provided that guidelines regarding the use maintenance or service are observed pursuant to following conditions The warranty is invalid in case of improper use negligence modification or unauthorised product s servicing The scope of the war...

Страница 13: ...g valve and a diving regulator must be carried out at least once a year servicing activities must be carried out with the use of suitable service kits by a service centre authorized by SCUBATECH the guidelines for use operation and maintenance of a demand regulator pressure reducing valve and a diving regulator must be observed IMPORTANT The warranty is invalidated should any repairs or adjustment...

Страница 14: ...14 CONTROL INSPECTION CARD Inspection date Technical condition assessment Serviceman s surname Signature and stamp ...

Страница 15: ...15 11 Manufacturer information SCUBATECH Ltd ul Lubieszyńska 2 71 087 Mierzyn Tel fax 00 48 914 530 017 e mail scubatech scubatech pl 12 Notes ...

Отзывы: