Scubatech R TEC Скачать руководство пользователя страница 9

21

WARRANTY CARD

of SCUBATECH  pressure regulator, breathing apparatus

The warranty coverage has a ten year warranty by SCUBATECH for the first user of the
pressure regulator, breathing apparatus and ensures that it is free from production and
material defects .  The following requirements must be fulfilled for the validity of the
warranty card:
1. The purchase must be made in a SCUBATECH  authorized shop.
2. The owner of the pressure regulator, breathing apparatus is the person listed on the

warranty card.

3. The servicing of pressure regulator, breathing apparatus must be conducted at least

annually by an authorized SCUBATECH service center.

4. The instructions on how to use, operate and maintain the pressure regulator , breathing

apparatus must be followed.

IMPORTANT !

Inspections or servicing conducted by unauthorized persons lead to the loss of warranty.
Defects caused by improper operating or mechanical damages are not covered by the
warranty.

HEADQUATERS OF THE COMPANY:
SCUBATECH LTD.
DERDOWSKIEGO STREET 8
71-087 SZCZECIN
TEL/FAX: (004891) 453 00 17

The owner’s name
……………………………………………………………………………………………..

Adress
………………………………………………………………………………………………
……………….

Model
………………………………………………………………………………………………
……………….

Date of purchase:                                                                Stamp and signature of seller:

SCUBATECH Sp. z o.o.

ul. Derdowskiego 8

71-047 Szczecin

tel.: 0 91 453 00 17

[email protected]

Содержание R TEC

Страница 1: ...13 SCUBATECH DEMAND REGULATORS R 2 ICE R 2 SPECIAL R 5 ICE R 5 TEC V 2 ICE USER MANUAL WARRANTY CARD SERVICE BOOK ...

Страница 2: ...h the requirements of EN 250 2003 A1 2006 norm WARNING SCUBA diving may be potentially hazardous for the untrained individual Therefore before attempting to use any SCUBA equipment an individual must receive training and certification WARNING Standard versions of our demand regulators cannot be used with gas mixtures with more than 40 of oxygen Failure to adhere to this warning may result in serio...

Страница 3: ...arated from outer environment This solution predisposes the above first stage regulators for using in extreme conditions and they are also designed for advanced divers The main function of the first stage is to reduce high pressure output of the scuba cylinder to constant overpressure of 9 0 9 5 Mpa overambient pressure changeable depending on the depthWith the growth of hydrostatic pressure durin...

Страница 4: ...orities Demand regulators R 2 ICE R 2 SPECIAL R 5 ICE R 5 TEC V 2 ICE can only be supplied with air compatible with demands of PN EN 12021 norm Demand regulators R 2 ICE R 2 SPECIAL R 5 ICE R 5 TEC V 2 ICE are compatible with all devices monitoring cylinder air pressure for usage with first stages of R 2 ICE R 2 SPECIAL R 5 ICE R 5 TEC V 2 ICE with thread connector 7 16 LP ports are compatible wit...

Страница 5: ...IT TOO STRONGLY Slowly open the cylinder valve quick opening of the valve may result in shortening of life of pressure regulator seat Check the functioning of demand regulator before diving Listen carefully to all connections on demand regulator and check whether the air is not coming out of it Check whether the air supplying the regulator does not smell in an unpleasant way Press the purge on the...

Страница 6: ...he entrance of DIN srew on the first stage Check if all HP and LP ports are plugged or joined in a proper way These procedures are especially crucial when diving in salt or chlorinated water While cleaning the demand regulator DO NOT depress the purge on the second stage If the purge is depressed water will enter the system possibly causing damage to the first and second stages While rinsing the b...

Страница 7: ...ring the dive It is advisable to use the above mentioned system in first stages used for dives in deep water below 30m To reduce the risk of freezing the demand regulator we should With the air temperatures close to 0 C and less avoid operating the regulator out of water avoid breathing or purging the regulator on the surface With the air temperatures close to 0 C and less stay as short as possibl...

Страница 8: ...or a longer period of time it is advised to have it serviced maintained and controlled the regulator may require more often servicing depending on how often it is used and in which environment it operates Periodical inspections reparations and all other actions influencing the operation of demand regulator MUST BE CONDUCTED BY THE MANUFACTURER OR AUTHORISED SERVICE CENTER Dismantling or assembling...

Страница 9: ...servicing of pressure regulator breathing apparatus must be conducted at least annually by an authorized SCUBATECH service center 4 The instructions on how to use operate and maintain the pressure regulator breathing apparatus must be followed IMPORTANT Inspections or servicing conducted by unauthorized persons lead to the loss of warranty Defects caused by improper operating or mechanical damages...

Страница 10: ...22 ANNUAL INSPECTIONS AND INFORMATION ON INSPECTIONS DATE SERVICE PERSON NAME NOTES STAMP AND SIGNATURE ...

Отзывы: