![SCT Scout SC4415 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/sct/scout-sc4415/scout-sc4415_user-manual_1220014029.webp)
Document# SCT-UM026FVC
Page 29 of 46
Confidential
Synopsis
buffer <SELECT>
Description Enable Buffer Mode and select the active Command Queue
Detail
Buffer Mode:
Enables the ability to load multiple commands into the specified Command Queue.
Commands are held in the queue until a trigger is received, enabling controlled bulk
execution of the queued commands. See ‘
’ for information about trigger
sources and operation.
<SELECT> Command Queue:
1 = Primary Queue
2 = Secondary Queue
To abort Buffered Mode and return to Immediate Mode, issue the ‘
’ command.
5.1.10
trigger_in
Name
trigger_in
Queue No
Synopsis
trigger_in <SOURCE> [<REPEAT>]
Description Trigger the execution of the Command Queue
Detail
Command Queue Input Trigger:
<SOURCE> Trigger Source:
Select the trigger input source that will execute the commands loaded into the
Command Queue(s). The Command Queues are executed differently depending on
the trigger input source selected.
1 = Software Trigger (default)
Executes the Primary Command Queue followed by the Secondary Queue.
2 = Hardware Trigger
Executes each of the Command Queues depending on the edge transition of the
hardware signal detected at the Trigger Input pin.
Positive Edge = Primary Queue
Negative Edge = Secondary Queue
<REPEAT> Repeated Trigger:
Repeat Trigger allows for the commands in the Command Queues to persist between
multiple trigger signals. When set, the repeat option is latched until the '
command is issued. If the trigger SOURCE is specified as a Software Trigger,
commands will not be executed until the following trigger command i.e. 'trigger_in 1'.
1 = Enabled
To abort Buffered Mode and return to Immediate Mode, issue the ‘
’ command.
5.1.11
trigger_out
Name
trigger_out
Queue Yes
Synopsis
trigger_out
Description Manually pulse the trigger output pin
Detail
Trigger Out Modes:
There are two trigger output configurations:
Automatic (default)
The trigger output is automatically pulsed at the start of the Command Queue
execution.
Manual
The trigger output pin generates a one-shot pulse.
Execution of this command disables the automatic triggering and executes a manual
trigger. To restore the trigger output back to the automatic mode, issue the ‘
command.
5.1.12
clear
Name
clear
Queue No
Synopsis
clear