![SCT Scout SC4415 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sct/scout-sc4415/scout-sc4415_user-manual_1220014013.webp)
Document# SCT-UM026FVC
Page 13 of 46
Confidential
Output current (Max)
20mA
Table 2.5.3-1 – V
IO
Electrical Specifications
2.6
Status LED
When Scout is first powered up, the status LED provides an indication that the unit has booted and is ready for use.
Once the LED is illuminated, Scout is in a responsive state and will accept connections via the programming interface.
The status LED can also be manually controlled using the programming interface and the
prove to be useful to help identify a specific Scout unit in a circumstance where multiple units may be connected to a
single host computer and the relationship between the programming interfaces and the physical devices is unknown.
2.7
Physical Details
The physical dimensions of the SC4415 are detailed in Figure 2.7-1.
Figure 2.7-1 – Product Dimensions
Additional specifications such as environmental, weight, and ESD protection are listed in Table 2.7-1.
Description
Value
Operating
Temperature
0°C to 70°C
Storage Temperature
-40°C to 85°C
Humidity
5% to 85% non-condensing
ESD Protection
HBM JESD22-A114E Class 3B exceeds 8000V
MM JESD22-A115-A exceeds 200V
CDM JESD22-C101C exceeds 1000V
Table 2.7-1 – Additional Product Specifications