13 TRX
175
Defines the time (in seconds) that the scanner waits after the end of a link, before it
switches to the next channel. The waiting time for the re-synchronization of AMTOR is
not influenced, as the phasing condition in AMTOR ARQ is interpreted internally within
the PTC as a continuous connect, and the scanner therefore remains switched off.
13.19
XScan
Default setting: none
Parameter: X Channel number 1… 32
S Switch 0 or 1
The
XScan
command allows the Scan parameter to be set for a channel defined within
the TRX list.
As an alternative to the previous scan enabling possibility of two arguments (e.g. S C 5),
that
toggled
(switched) the scan function on or off, the
XScan
command allows
particularly channel scan definition:
Set Scan parameter of channel 10 to NO.
trx:
XS
10 0
<Return>
Set Scan parameter of channel 4 to YES.
trx:
XS
4 1
<Return>
The
XScan
command is particularly useful in the initialization/configuration file of the
PTC-IIIusb, because a new defined state can be set without knowing the current state of
the scan parameter.
13.20
YType
Default setting: 0
Parameter: 0 YAESU Type FT-890
1 YAESU Type FT-990/FT-1000
2 YAESU Type FT-1000 MP
3 YAESU Type FT-100
4 YAESU Type FT-920
5 YAESU Type FT-847
6 YAESU Type FT-817/FT-857/FT-897
7 YAESU Type FT-950
8 YAESU Type FT-2000
9 YAESU Type FT-9000
Specifies a special YAESU transceiver as sub-type to enable the PTC-IIIusb to read back
the frequency from the transceiver. This command is only effective, if a YAESU
transceiver has been selected with the
TYpe
command.
The YAESU transceiver types 7-9 are only usable in combination with the setting
KType
= 1, because this transceivers use an adapted Kenwood protocol. The
YType
command
must be given prior to the
TYpe
command. See example in chapter
.