SCS 770067 Скачать руководство пользователя страница 1

TB-9102

 Page 1 of 18

© 2020 DESCO INDUSTRIES INC

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

WS Aware Monitor

Installation, Operation and Maintenance

August 2020

Description

The SCS WS Aware Monitor is a dual workstation 

continuous monitor for operators, ESD worksurfaces 

and metal tools. It continuously monitors the 

path-to-ground integrity and body voltage of two 

operators, as well as the path-to-ground integrity for two 

conductive or dissipative worksurfaces and two metal 

tools. It also continuously monitors for electromagnetic 

interference (EMI) on two metal tools which may cause 

electrical overstress (EOS) damage. The WS Aware 

Monitor eliminates the need for periodic testing and 

record keeping of wrist straps.

Made in the

United States of America

 USER GUIDE TB-9102

The WS Aware Monitor is designed with digital signal 

processing technology for true continuous monitoring 

(versus pulsed or intermittent) of wrist strap functionality 

(path-to-ground and presence of 1 megohm resistor) 

and operator safety according to accepted industry 

standards without capacitance variations from personnel 

or environment. Digital signal processing technology 

uses dual-wire wrist straps to apply an ultra-low test 

voltage of 0.05V onto the operator for the handling of 

sensitive components.
The WS Aware Monitor features operator body voltage 

detection. It will alarm if the operator generates or 

comes in contact with voltage that would be dangerous 

to an ESD susceptible item.
The WS Aware Monitor continuously monitors two metal 

tools for electromagnetic interference (EMI). EMI can 

cause equipment lockups and malfunction. The WS 

Aware Monitor will alarm if EMI is detected. Each WS 

Aware Monitor is calibrated with accepted procedures 

and standards traceable to the National Institute of 

Standards and Technology (NIST) and includes a 

certificate of calibration.
ANSI/ESD S20.20 section 7.3 states “Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.” Per ANSI/ESD S1.1 Annex A.3 Daily 

(wrist strap system) testing may be omitted if constant 

monitoring used.” Per ESD Handbook ESD TR 20.20 

section 5.3.2.4.4 “Typical Test programs recommend 

that wrist straps that are used daily should be tested 

daily. However, if the products that are being produced 

are of such value that knowledge of a continuous, 

reliable ground is needed, and then continuous 

monitoring should be considered or even required.”
The WS Aware Monitor and its accessories are 

available as the following item numbers:

Item

Description

770067

WS Aware Monitor, with Standard Remotes

770068

WS Aware Monitor, with Big Brother 

Remotes

770069

Power Relay, for WS Aware Monitor

770064

Power Adapter, 100-240VAC Input, 7.5 

VDC 1.5A Output, All Plugs

CTE701

Workstation Monitor Checker

CTA242

Operator Remote, Standard

CTA243

Operator Remote, Big Brother

CTA245

Replacement Wrist Strap Jack PCB

770055

SMP Software

Figure 1. SCS 770067 WS Aware Monitor with Standard 

Remotes

Figure 2. SCS 770068 WS Aware Monitor with Big 

Brother Remotes

Содержание 770067

Страница 1: ...comes in contact with voltage that would be dangerous to an ESD susceptible item The WS Aware Monitor continuously monitors two metal tools for electromagnetic interference EMI EMI can cause equipment...

Страница 2: ...and prevent ESD events Quantifiable data allows you to see trends become more proactive and prove the efficiency of your ESD process control system SMP is sold separately Click here to learn more Pack...

Страница 3: ...ive resistance and electromagnetic interference EMI Use 25 28 AWG wire to connect the metal tool to this terminal J Monitored Mat 1 Terminal Monitors a worksurface mat for proper dissipative resistanc...

Страница 4: ...le to the operators Locate them within reach of the included mini DIN operator remote cables Use the operator remotes mounting tabs to secure them underneath table tops or equipment 4 Connect the incl...

Страница 5: ...ack located on the right side of the WS Aware Monitor Route the wire from the supply to a nearby AC outlet and plug it into the outlet Make sure the voltage and frequency match those listed on the pow...

Страница 6: ...WS Aware Monitor Connect the opposite end of the cable to the green receptacle on the Power Relay 2 Connect the included power cord to the power inlet on the Power Relay Connect the opposite end of th...

Страница 7: ...WS Aware Monitor to SMP via a local area network LAN SMP must be installed to a PC prior to using this procedure The diagram shown below illustrates a common SMP system setup that utilizes the server...

Страница 8: ...that the Ethernet cable is securely connected to your network and WS Aware Monitor The LEDs on the Ethernet port will illuminate when a connection to the network is established 2 Open SCS SMP Server...

Страница 9: ...est 909 627 9634 Website StaticControl com 5 A message will appear and display Starting SMP Server Click the SMP Server icon located in the Windows taskbar 6 SMP Server will now indicate Active server...

Страница 10: ...rial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 8 Open SCS SMP Admin 9 The window for SMP Server Admin will appear 1 unassigned is representative of the WS Aw...

Страница 11: ...rd NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 10 Enter a building name and then click the OK button 11 The building name will appear on the navigation pane in SMP Server Ad...

Страница 12: ...Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 13 Enter a floor name and then click the OK button 14 The floor name will appear on the navigation pane in SMP Server Adm...

Страница 13: ...st 919 718 0000 West 909 627 9634 Website StaticControl com 16 Enter a line name and then click the OK button 17 The line name will appear on the navigation pane in SMP Server Admin 18 Click on the li...

Страница 14: ...cControl com 19 The serial number for the WS Aware Monitor will appear This number will resemble the number found on the monitor s serial label with the exception of one zero For example if the serial...

Страница 15: ...ES INC Employee Owned SCS 926 JR Industrial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 21 Open SCS SMP Client 22 Verify that the WS Aware Monitor was added to...

Страница 16: ...e s Wrist Strap Jacks Should the operator remote s wrist strap jacks begin to show wear and tear damage they can be replaced using the SCS CTA245 Replacement Wrist Strap Jack PCB and the following pro...

Страница 17: ...100 240VAC 50 60 Hz Output 7 5 VDC 1 5 A Output Plug Polarization Center Positive Output Plug 5 5 mm O D x 2 1 mm I D x 9 5 mm L Operator Wrist Strap Dual Wire Amount Monitored Operator 2 Amount Non M...

Страница 18: ...bs 0 05 kg Country of Origin United States of America 770069 Power Relay Power Operating Voltage 90 120 VAC 50 60 Hz Output Voltage 90 140 VAC Max Load 12 A Connectivity Input C 13 C14 Output 4x NEMA...

Отзывы: