27
EN
LED 1 System Learning:
LED1 will be on when remote controls are activated.
LED 2 System learning:
LED 2 blinks twice per second during normal operation and once per
second during learning. Static LED2 means incorrect programming.
LED 3 Photocells:
LED 3 will be on when photocells are not aligned or when there’s an
obstacle in between.
LED4 start :
LED 4 will be on if the switch of the transmitter, key selector, or the push
button is activated.
Figure 1(4)
LED1
RF-Learn
RF1 Remote receive board
SYS-Learn
SW1:Set
1. D/S set
2. Over_C1
3. Over_C2
4. Auto
5. Ph
LED2
LED3
LED4
1 2
3
4
5
6
7
8 9 10
11 12 13 14
Transformateur
NONE
panneau
solaire
FI
Fusible T20A
250V
antenne
TX
sélecteur
à clé
bouton
poussoir
photocellules
RX
M1
M2
fil rouge /
marron
Fusible 2AL 250V
230V ~
fil bleu
OFF
ON
feu
clignotant
24V 10W
serrure
12/24V
Press “RF-learn” button for 2 seconds, and the LED1 will be on; then press the transmitter top left button, then top right
button. The LED1 will blink twice and stay on for 10 seconds then be off. And the remote memorize has completed.
D7- LED indication
D8- Remote controls learning process
D9- System learning process for double leaf gate
ELECTRONIC CARD
The remote control memory storing operation must be over before starting the final system learning
process.
The LED2 light will remain ON until the system learning process is not over. Let your gate totally opened. Press
«SYS-learn» (until the LED2 light begins to flash once every second, instead of twice every second as it normally
would), then press the upper-left key for a double gate.
The system learning process will be as follows, step by step:
After step 6, the system learning process is complete. You can use it with the remote control:
double gate full opening
pedestrian opening (single gate)
1
2
3
1
2
3
4
5
6