6
EN
C- WIRING / INSTALLING
C- WIRING / INSTALLING
C1- Wiring diagram
Handset
Outdoor station
LOCK OR STRIKE : OPTIONAL
Connecting cables
not provided
From 0 to 50 metres: use 0.75 mm² cable
From 51 to 100 metres : use 1 mm² cable
From 0 to 10 metres :
use 1mm² cable.
1
2
3
4
4
3
6
5
2
1
C2- Attaching and connecting the elements
•
Attach the outdoor station at a height of 1.5 metres mounted on a flat wall back plate.
•
Installation under a porch or a covered area is highly recommended.
•
Remove the top from the panel, slightly lift then slide off the front panel.
•
Connect the outdoor station wire and insert the outdoor station on its support.
•
Attach the interior unit at a height of 1.5 metres on a flat wall. First fit the rear plastic support, connect the wires
and place the handset on its support.
• Connect the interior unit.
•
Perform functional test before finalizing fixing of the elements.
1.5 m
Back plate outdoor station
96
187
After installing and testing, place a clear silicon seal on the top and sides of the outdoor station (not on the
bottom) to avoid any risk of infiltration.
Notice_PAF0001_V0821_indH.indd 6
Notice_PAF0001_V0821_indH.indd 6
16/08/2021 16:18:33
16/08/2021 16:18:33