Electrical Terminations

With all SCS Industries Spas, you will usually find the Control Box at the same end of the Spa as the controller 
Touchpad Control Centre.
There are a number of electric controllers that you may find on your SCS Industries Spa. The 

Balboa

 system is the  

unit most widely used by SCS Industries. If it requires direct wiring the terminal connection can be found inside the 
Control Box.
The Balboa system has a Terminal Block in the control 
box similar to that in adjacent photo.
To gain entry to the Engine Bay, remove service access 
doors with Allenkey (supplied). The Engine Bay can be 
found below the Digital Touchpad Control Centre.
Be sure to take extreme care when connecting power 
cables to the unit, as incorrect connection can cause 
damage to the Control System.
Power supply to the Spa needs to be on a dedicated 
circuit and be protected by a Residual Current Device 
(Safety Switch), as well as the correct size cable and 
circuit breaker protection.
In-ground Spas are controlled from air buttons located on the topside of the Spa. All electrical equipment must 
be located away from the Spa itself. (The distance may vary, depending on the state and country codes and 
standards). Please read instructions supplied with the air switches in relation to mounting distance from the air 
buttons installed in the Spa shell.

The Spa is fitted with a Balboa Touchpad Control Centre. The instruction sheet for your Spa Control Centre will be 
supplied with your Spa. The instruction sheet shows step by step operation procedures to operate pumps, blower, 
light (if applicable), ozone (if applicable) also for the control and setting of filter times and filter durations.

Pg. 16

Power Consumption

Touchpad Control Centre 

(Portable Spas)

Terminal Block

Содержание Portable and In-Ground Spas

Страница 1: ...Portable and In Ground Spas Operating Manual The Best Built Spas in the World TM...

Страница 2: ...proper care and service of your new Spa and the correct chemical maintenance of the water your Spa will provide years of enjoyment Please take time to read this manual carefully before operating your...

Страница 3: ...talling Plumbed Shells 11 13 Plumbing of In Ground Spas 14 Electrical Connections 15 16 Requirements Note To Electrician Electrical Terminations Touchpad Control Centre 16 Checklist Prior To Filling Y...

Страница 4: ...Light 26 27 Changing The Coloured Lens Replacing The Light Globe Inside Deluxe Models Only Outside Standard Models Only Jet Information Ozonator 28 Air Control 29 Aromatherapy Dispenser 29 Air Injecto...

Страница 5: ...s lights and diagnostic codes ControlBox wherepowersupply blower ozone if used and circulation pump are connected Located in the engine bay of your spa Main and Boost Pump if applicable Located in the...

Страница 6: ...or additional chemical requirements when using ozone contact your Dealer There are two types of ozone units used in SCS spas For further details see the Ozonator section on page 28 of this manual Type...

Страница 7: ...de of the Spa This canister holds the Aroma Beads To access the canister unscrew the cap in an anti clockwise direction Ensure blower is not operational when removing cap JetPak TM if fitted the ultim...

Страница 8: ...viced at the recommended intervals as detailed in the Spa s manual or Warranty will ensure your Warranty remains valid Access IMPORTANT NOTE As stated in the Pre Delivery Manual when installing the Sp...

Страница 9: ...ylic on the base of the Skimmer box where the filters fit into the plumbing Identification Compliance Label Portable Spas SCS Industries Portable Spas come complete with their own Identification Compl...

Страница 10: ...user should check the water temperature with an accurate thermometer A temperature of 38 C is considered safe for a healthy adult Special caution is suggested for young children 3 It is recommended t...

Страница 11: ...ponents dry and protect them from continual damp conditions and will also aid you when draining the Spa for maintenance If you are installing your Spa indoors pay close attention to the flooring benea...

Страница 12: ...should be clear of the pool surround no weight is to be taken by the rim Fill the bottom of the Spa pool with water to cover all plumbing outlets and check for water leaks rectify if necessary Empty w...

Страница 13: ...major share of the weight The reclining area will be supported where it touches the horizontal support structure When you are satisfied the Spa pool will sit level and be firmly supported remove the S...

Страница 14: ...the seat and reclining areas Constantly check the Spa pool for level when back filling Complete the Spa pool surround and plumbing Sloping Site Installation Brick Surround When installing your Spa poo...

Страница 15: ...ion of switch Our In ground Spas are controlled via air switches buttons not by the electronic method mentioned in this manual for Portable Spas Blower installation The blower needs to be mounted a mi...

Страница 16: ...ower 6 Ensure Spa is connected on a dedicated circuit protected by a safety switch Note to the Electrician Drill appropriate size hole through base for cable and conduit entry Ensure cables are fitted...

Страница 17: ...ntrol System Power supply to the Spa needs to be on a dedicated circuit and be protected by a Residual Current Device Safety Switch as well as the correct size cable and circuit breaker protection In...

Страница 18: ...service panels around the exterior of the Spa inspect for any item that may have come adrift or loosened during transport Leave doors off until Spa is filled with water and a check for l eaks has be...

Отзывы: