background image

page 1 of 2 

page 2 of 2 

•  Cleaning the Scanner Mirror – continued…

5.  The lights to the left of the front button 

will start to flash through a sequence, 
starting with the (second) red light, 
then cycling through to the (third) 
amber light, then onto the (fourth) 
right hand green light, before starting 
the sequence again.

 

As soon as the right hand green light is on, press the front button. This 
selects 

“all screws but three”

 mode. So you can access the screws that hold 

the back light and metal plate in the correct position.

6.  Use a Phillips screwdriver to undo all the screws you can see, that hold down 

the backlight and metal tray.

7.  Close the lid of the scanner again, and when the amber light is on, on the 

front panel, press the front button. 

 

This moves the scanner tray into the 

“three remaining screws’ 

mode.

8.  Undo the three remaining screws at the left hand side of the scanner bed.
9.  Move the scanner back into the 

“all screws but three”

 position. (press front 

button whilst green button is on),  and remove the metal plate.

10. Lift the front edge of the back light unit - using the back edge as a 

‘hinge’- so that you can get at the mirror at the left hand side (positioned 
underneath the lamps on your scanner), taking care not to damage the very 
fine fluorescent tubes to the left and right hand side of the back light area, 
as these tubes are very delicate and very expensive!

11. Take a photographic lens brush (one with a small air bag attached to blow 

dust away) and gently wipe the surface of the mirror, being careful not to 
scratch it at all.
For smears and grime you can wipe the mirror with a lint free cloth and any 
lemon or vinegar based window cleaning solution. Screen UK recommend 
optical wipes that have been impregnated with lens cleaning solution. 
(Opticians sell them). Avoid any glass cleaner that leaves smears of any kind.

12. Once you have cleaned the mirror, drop the backlight unit down carefully, 

making sure that all the holes for the screws are aligned properly.

13. Replace the metal tray that hold the grid and backlight into position, getting 

all the screw holes properly aligned, then replace all screws but three. (Your 
scanner should already be in the correct position to do this - if not you need 
to press the button on the front of the scanner as the right hand green light 
is on, to get the scanner in the correct position, see step 5 above).

14. Get the scanner bed back into the 

“remaining three screws”

 position, (press 

the button on the front of the scanner as the amber light is on, to get the 
scanner in the correct position, as before). 

15. Replace the remaining three screws. Switch the scanner off, and back on 

again without holding down the front button to get the scanner bed back in 
the correct position.

16. Replace the glass tray. Your scanner is now ready to use.

NB: Do not attempt this procedure unless you feel confident to do it 

correctly, and have been shown how by a Screen Engineer.