The power cord will exit from the left hand side of the box, unless ordered otherwise. Now power the screen 

down while being careful of the following warning. 
 
Note: The door should open in the first second of operation, if this fails to happen, stop the screen at once, and 
open it by hand, as sometimes the door is forced closed during transportation or installation. 
 
 
Specifications 
 
The dimensions below are indicative of standard specifications, but if the screen is of a side tension variety, then 
the following specifications are not relevant, so please seek clarification if necessary. 
 

Width Height 

Length 

Weight 

206 mm 

200 mm 

456 mm Longer than the Screen 

Picture Width 

60 TO 100KG 

 
For Screen Picture Width see the specified screens technical sheet or seek advice from the sales department. 
 
 
Connect Control Module – Standard 
 

The following procedures requires access to the Connect Module through removal of the control box lid and as 
such you MUST remove all power from the unit before proceeding otherwise  electrocution or serious injury may 
occur. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 

rc

v

 

LED

U

C

D

Connect Network

In

Out

Contact Close

Input

IR Receiver

Input

Connect Network

In

Out

Next Connect Module
Maximum 9 Modules

Up

Down

Momentary Contact Close

rc

v

 

M

Motor Output

240 V

Input

IEC

Socket

1    2    3    4

Motor Wiring
Pin 1 - Brown Screen Down
Pin 2 - Black Screen Up
Pin 3 - Yellow/Green Earth
Pin 4 - Blue Neutral

Infra Red

Receiver

RJ12 Connector
6 Core wired
straight through

In

Out

4

5