CONNECT NETWORK CONNECTION
•
The connect network allows for the connection of up to nine (9) iConnect 240V or 24V
modules.
•
Connection between modules is via a RJ12 6 Core cable wired straight through.
•
Connection is made by connecting from the RJ12 connect network out to the RJ12 connect
network in.
•
A 10 metre RJ12 Connect daisy chain cable is available (Product Code 6500104).
CONTACT CLOSE INPUT
•
Requires two (2) contacts - one for up command and one for down command.
•
Contact operation is momentary dry contact, command is sent when contact is reopened
(Lagging Contact)
•
Contact close input is local only, can be parallel wired to other modules for multiple
control.
•
Contact close can be reprogrammed to single latched mode by using the 6 button infra red
transmitter if required. (Contact Screen Technics for details)
•
Two button impulse switches are available (Product Code 3500998)
INTERFACING WITH THIRD PARTY CONTROL SYSTEMS
The iConnect module can be connected to the iReply (Product Code 6500300) interface via the
connect network to provide
•
RS232 control
•
RS485 Control
•
TCP/IP Control
•
USB Control
(Contact Screen Technics for details.)
FACTORY RESET PROCEDURE
Should you experience problems with the operation of the iConnect module at the time of
installation, a factory reset can be initiated to confirm operational integrity of the iConnect
module.
•
Infra Red receiver must be connected to the iConnect module
•
Disconnect module from mains power for 20 seconds
•
Reconnect module to mains power.
•
LED on iConnect module will change from green to red (module is now in program mode).
•
Using the 6 button infra red remote push buttons in the sequence of:
- Stop 1 - Stop 1 - Stop 2 - Stop 2 - Stop 1 - Stop 1
- To confirm that the reset was performed the projection screen, AV lifter or roller blind will
jiggle up and down. The module is now reset to factory standard (Infra red operation is
group one (1) and contact close is momentary operation.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
o
o
Contact Close
Input
•
•
•
•
•
•
•
•
•
•
•
rc
v
I
R
IR Receiver
Input
rc
v
I
R
Infra Red
Receiver
rc
v
I
R
IR Receiver
Input
MAINTENANCE AND SERVICING
Although this unit does not require any regular servicing, it is recommended that a visual
inspection of the device take place on a scheduled yearly basis inspecting for the following:
Please note that no persons should be beneath the device during this testing proceedure, or in
day to day operation.
1. Inspect wire cabling for any fraying, and that the cable is winding neat on the cable winding
drum.
2. Inspect the power and AV source cable that travels up and down with the unit to ensure no
damage or tangling has occurred.
3. Operate the unit fully down and up to ensure smooth operation and inspect the fall arrester
mechanism attached to the winding tube for free travel every rotation (it will fall into place
and make a clicking sound).
4. A full visual inspection looking for any part of the device that appears to be faulty or failing.
Should any concerns arise from these inspections please immediately seek advice from Screen
Technics, and secure the device so that it is not operational until all matters are resolved.
Should you have any questions regarding the installation of our products please call our sales
desk on +61 2 4869 2100 for assistance