background image

FOREWORDS:

Typographic Convention

So that our manuals are easy to read and understand, we have adopted the following 

typographic convention:

Iconography

Indicates additional information concerning the subject.

Indicates a potentially hazardous situation which, if not avoided, coul result in 

serious injury or death.

Indicates a potentially hazardous situation which, if not avoided, could result in 

minor or moderate injury. It may also be used to alert unsafe practices.

Emphasis an important point which must not be ignored.

Содержание MCS Serial IP Adapter

Страница 1: ...MCS Serial IP Adapter Installation Manual Revision A 2007 07 06 ...

Страница 2: ......

Страница 3: ...es additional information concerning the subject Indicates a potentially hazardous situation which if not avoided coul result in serious injury or death Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury It may also be used to alert unsafe practices Emphasis an important point which must not be ignored ...

Страница 4: ......

Страница 5: ...evision A 2007 07 06 Screen Research 2006 Action W Written R Page revised A Page added D Page deleted C Rewritten completely Date Rev N Action New pages Rev révisées Reason For Change 2007 07 06 A W New document Updating Tab MCS Serial IPAdapter ...

Страница 6: ......

Страница 7: ...dapter 10 3 Configure the MCS Serial IP Adapter 12 4 Assign IP Address 16 5 Configure Serial Port 17 6 Apply Changes 18 7 Reach Connection Quickly 19 8 Check Configuration 20 9 Confirm Connection 21 10 Send A Command Via Internet 22 11 Send A Command Via HyperTerminal 23 A Legal Information 27 Table Of Contents MCS Serial IP Adapter ...

Страница 8: ......

Страница 9: ... best results from your MCS Serial IP Adapter and to operate it safely This manual contains information on how to do that please read it carefully before operating 1 Introduction MCS Serial IP Adapter Contents Description Yes No Remarks MCS Serial IP Adapter 1 piece Transformer 1 piece Null modem cable 1 piece CD Rom 1 piece Technical Sheet 1 piece Installation manual 1 piece ...

Страница 10: ...esearch 2006 1 Hook up the power to the MCS Serial Ip Adapter The Power and Ready leds are blinking 2 Connect the Null Modem cable between your computer and the MCS Serial Ip Adapter 2 Connect The MCS Serial IP Adapter 2 Connect The MCS Serial IP Adapter MCS Serial IP Adapter ...

Страница 11: ...11 MCS Seria IP Adapter Installation Manual Revision A 2007 07 06 Screen Research 2006 3 Slide Data Console switch to the Console mode 2 Connect The MCS Serial IP Adapter MCS Serial IP Adapter ...

Страница 12: ...s to configure the MCS Serial IP Adapter 1 Click on the button Start 2 Choose the HyperTerminal application in Programs Accessories Com munication 3 Configure The MCS Serial IP Adapter It is not necessary to fill in the fields requested in the parameters when using The HyperTerminal program for the first time 2 Configure The MCS Serial IP Adapter ...

Страница 13: ... 06 Screen Research 2006 3 Enter a name to describe the connection Choose an icon then in the Connection Description window 4 Select the COM port to which the adapter is connected in the Connection window 3 Configure The MCS Serial IP Adapter MCS Serial IP Adapter ...

Страница 14: ...al IP Adapter 5 Select the following parameters to configure the COM port 9600 for Baud rate 8 for Data bits none for Parity 1 for Stop bits None for Flow control 6 Click on the button OK and go to the Main Menu 7 Take the phone off the hook to indicate the connection to the adapter 8 Press Enter key at the terminal emulation program ...

Страница 15: ...ch 2006 3 Configure The MCS Serial IP Adapter MCS Serial IP Adapter 9 Enter the user name and password Factory default settings of the user name and password are both admin You can change by the terminal IP address client server configuration serial port configuration login choice ...

Страница 16: ...P Adapter Example of an IP address assignation 1 We assigned to the adapter the static IP address 192 168 1 1 2 We chose an unused IP address by a computer connected to this network 192 168 1 11 IP address 3 We configured the subnet mask 255 255 255 0 4 We configured the IP address of the computer connected to Internet 192 168 1 111 5 We chose command set ip static 192 168 1 11 255 255 255 0 192 1...

Страница 17: ...y default settings 2 Check this configuration with command get serial Baudrate 9600 Data_bits 8_bits Stop_bits 1_bit Flow_control None DTR_option Always_high DSR_option None Interchar_timeout ms 50 Select the following parameters to configure the connection serie and the driving of the MCS via the MCS BRS baud rate 9600 data bits 8 parity none stop bits 1 flow control none ...

Страница 18: ...on Manual Revision A 2007 07 06 Screen Research 2006 Save changed values using save and reboot commands as follows 6 Apply Changes 6 Apply Changes MCS Serial IP Adapter save OK reboot Reboot the MCS Serial IP adapter using reboot command ...

Страница 19: ...arch 2006 7 Reach Connection Quickly MCS Serial IP Adapter 7 Reach Connection Quickly 1 Save connection settings from computer towards the MCS Serial IP Adapter 2 Connection is accessible directly by the menu Start Programs Accessories Communication HyperTerminal Connection name ...

Страница 20: ...connector of the MCS Serial Ip Adapter with your switch The Link LED is blinking 8 Check Configuration 8 Check Configuration MCS Serial IP Adapter 4 Connect the series port of the adapter to the MCS BRS which is itself connected to a MCS 5 The adapter is connected to the network on the IP address defined before see chapter 4 Assign IP Address It drives the series port by protocol TCP IP on the 600...

Страница 21: ...Connect a MCS on the SYS1 port of the MCS BRS Commands for the MCS are 2 Type commands OPEN 1 and CLOSE 1 that is to say respectively 1o01004 et 1c01004 to test the MCS A click of the relay indicates that command was understood If you need more information about the MCS commands list consult the in stallation manual Motor Control System MCS 310 MCS 320 ...

Страница 22: ...your browser the IP address the port name the command name Example 10 Send A Command Via Internet 10 Send A Command Via Internet MCS Serial IP Adapter http 192 168 1 11 6001 1o01004 http 192 168 1 11 6001 1c01004 Prefix IP Address Port MCS OPEN 1 Command Prefix IP Address Port MCS CLOSE 1 Command ...

Страница 23: ...ia HyperTerminal MCS Serial IP Adapter 11 Send A Command Via HyperTerminal 1 Configure a new connection while being connected to protocol TCP IP 2 Type the IP address and the port number 3 The device is well connected connection is done automatically 4 Select File Preferences to see commands which are sent ...

Страница 24: ... Adapter Installation Manual Revision A 2007 07 06 Screen Research 2006 11 Send A Command Via HyperTerminal MCS Serial IP Adapter 5 Click on the button Configuration ASCII 6 Select Reproduce Locally The Typed Data 5 6 ...

Страница 25: ...A Command Via HyperTerminal MCS Serial IP Adapter 7 Type commands as below 1c01004 8 Command is correct the MCS BRS returns the LF command line break 9 Command is sent to the motor the MCS BRS returns the CR command return to the beginning of the line Cursor starts automatically on the next line ...

Страница 26: ...o 167 75 55 Europe No EP 2277083 Europe No US 7 777 947 B2 USA No US 7 466 483 B2 USA No US 2011 043908 USA USPTO 200 701 71 522 USA No 200480025260 9 China No 1126 CHENP 2007 India No 2006 524398 Japan pending ClearPix ClearPix 2 ClearPix 3 ClearPix 4k SilverPix 3D SilverPix 3D Sonic MultiPix 4K MultiPix 4K Sonic SolidPix SolidPix Sonic X Mask C Mask E Mask LeWing TheaterCurve Pi Grip E Grip Stop...