AC, LOW VOLTAGE (DC), AND CONTROL – WIRING

AC Wiring (AC Motor – Wireless control)

DC Wiring (AC Motor – Wired control)

DC Wiring (DC Motor – Wired control)

AC, LV (DC) Wiring

Marking

V+

V-

+

-

G

Description

Positive 24VDC
Negative 24VDC
485 Data Positive
485 Data Negative
485 Data Ground

24v DC Power Supply

RS485  Data+

RS485  Data-

RS485  Ground

Pigtail

Pigtail

Load (Black/Brown)

Neutral (White/Blue)

Ground (Green/Yellow)

*These colors on left are for USA, 
international are on the right

Load (Black/Brown)

Neutral (White/Blue)

Ground (Green/Yellow)

RS485 (+) - White

 

RS485 (-) - Orange

-

Power 7v DC - Red

-

-

-

Ground - Brown

Pin 1

Pin 8

Service Loop

NOTE: Red Service loop, can be cut to disable the DC 
output from an AC 485 motor.

Содержание Solo 3

Страница 1: ...INSTALLERS Please leave this manual with the owner Solo 3 Indoor 375 External Installation Instructions 4000XX Ι v 1 0 Ι 13 April 2022 ...

Страница 2: ...all transportation expenses This warranty is in lieu of all other warranties express or implied including warranties as to fitness for use and merchant ability Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have other rights which...

Страница 3: ...o 3 375 External Indoor 6 12 Power Options 8 11 AC Low Voltage DC and Control Wiring 8 Setting Up Wired Screen Using Moab 9 10 Wire Considerations 11 References 13 Servicing Solo 3 375 External Indoor 14 22 Inspecting the Roll 14 15 Tube Removal 16 17 Tube Installation 18 21 Wireless Sleep Mode 22 ...

Страница 4: ... per screen Screen Wall Brackets Screws Included 3 per Bracket IR Remote Din Rail Terminal Blocks and Bracket low voltage and or 485 PARTS IN THE BOX 375 Box Installation Remotes 1 per RTS screen Included remote s form factor may vary however functionality and performance is consistent Included in the box with hardwired control screens only ...

Страница 5: ...cer blocks to screen brackets NOTE Do not use more than four 4 spacer blocks per bracket Leveling Shims Used to level screen placement Before installing connect to screen brackets NOTE Do not use more than two 2 leveling shims per bracket SPACER BLOCKS AND LEVELING SHIMS OPTIONAL Spacer Blocks and Leveling Shims ...

Страница 6: ...all brackets as close to the end of the cassette as possible ensures better stability of the screen 1 Terminate pre wire with the supplied terminal block Data For 485 Only Header 24 VDC 24 VDC Data Data Data ground V V G Jamb INSTALLATION SOLO 3 375 EXTERNAL INDOOR Installation Solo 3 375 External Indoor ...

Страница 7: ...ed position 4 Ensure the terminal blocks are plugged in and installed in the brackets Proper position for installing Box INSTALLATION SOLO 3 375 EXTERNAL INDOOR Installation Solo 3 375 External Indoor Data Cable Power Cable NOTE Refer to the next page to see the wiring as per your power ...

Страница 8: ... Data Negative 485 Data Ground 24v DC Power Supply RS485 Data RS485 Data RS485 Ground Pigtail Pigtail Load Black Brown Neutral White Blue Ground Green Yellow These colors on left are for USA international are on the right Load Black Brown Neutral White Blue Ground Green Yellow RS485 White RS485 Orange Power 7v DC Red Ground Brown Pin 1 Pin 8 Service Loop NOTE Red Service loop can be cut to disable...

Страница 9: ...L 1 5 L 1 4 L 1 4 L 1 3 L 1 3 L 1 L 1 L 3 L 3 L 2 L 2 L 4 L 4 L 7 L 7 L 8 L 8 3 0 2 3 2 5 3 0 2 3 2 5 202311 EXT 202311 EXT 202312 INT 202312 INT VIEW VIEW VIEW VIEW 4 8 5 4 8 5 L IM IT L IM IT L O W E R L O W E R L IM IT L IM IT MOTOR ROTATION MOTOR ROTATION STANDARD REVERSE STANDARD REVERSE 9 V D C 9 V D C 4 8 5 4 8 5 DC MOTOR DC MOTOR 485 PAIRING 485 PAIRING S TO P S TO P U P P E R U P P E R IR...

Страница 10: ...IEW 4 8 5 4 8 5 L IM IT L IM IT L O W E R L O W E R L IM IT L IM IT MOTOR ROTATION MOTOR ROTATION STANDARD REVERSE STANDARD REVERSE 9VDC 9VDC 4 8 5 4 8 5 DC MOTOR DC MOTOR 485 PAIRING 485 PAIRING STOP STOP U P P E R U P P E R IR REC IR REC I R I R L E D L E D BOARD BOARD SETTINGS SETTINGS 6 6 3 3 T T S TO P S TO P 485 DEVICE 485 DEVICE DRY CONTACT PORT DRY CONTACT PORT 3 5mm 1 8 in mono TS 3 5mm 1...

Страница 11: ...Pre Wire Screen Pre wire Wire Gauge AWG 14 16 18 Maximum Supported Wire Length ft 250 150 100 24v DC Using 5 Conductor Wire 24v DC Using UTP Wire Wire between Janus terminal block face and the motor only Wire Gauge AWG 24 w o Spike 24 w Spike Supported Wire Length ft 100 375 Screen 150 375 Screen Blue Blue White Green Green White Brown Orange Brown White Orange White WIRE CONSIDERATIONS Wire Consi...

Страница 12: ...ion keeping the screen secure To finish installation continue with the steps below 6 Locating the channel running along the back of the screen hook the channel onto the wall brackets INSTALLATION SOLO 3 375 EXTERNAL INDOOR Installation Solo 3 375 External Indoor channels ...

Страница 13: ...d party Control system Scan the QR code alternately use this link to access https files screeninnovations com Downloads Installation Instructions Connectivity troy installation instructions pdf LinkPro Z Installation Instructions IP Control third party Control system Scan the QR code alternately use this link to access https files screeninnovations com Downloads Installation Instructions Connectiv...

Страница 14: ...t surface Beware of obstructions when removing cover if there is an obstruction unlatch the levers disconnect wiring and remove screen off the brackets to service laying on a clean flat surface 1a To service the Solo 3 begin by loosening the end cap locking screw on each end cap 1b To unlatch the cassette face and access the motor and screen material hold the end caps level and push upwards on eac...

Страница 15: ...imit to reduce the diameter of the roll lessening the chance of screen material interference when removing the cover To remove the cover pull the cover towards yourself rotating upwards slightly Inspection of the roll and accesss to the motor and screen material are now available with the cover removed ...

Страница 16: ...reinstallation after service completion SERVICING SOLO 3 375 TUBE REMOVAL Safety spacer Disconnect Power 1 Disconnect power and the safety spacer with needle nose pliers as shown below Wirefree Motor 24v DC Motor x1 Servicing Tube Removal ...

Страница 17: ...d caps Once the motor side clears the end cap pull the tube assembly away from the idler to complete removal NOTE At least two people are required to safely perform tube removal NOTE The screen system is now ready for any service If any concerns on swapping the motors or material tube arise call SI Screen Support at 512 832 6939 or email screensupport screeninnovations com Servicing Tube Removal S...

Страница 18: ...ully seated in their corresponding end cap recesses 2 Fully depress the spring loaded idler pivot the tube until the idler is in line with the idler bearing The idler can be released once it has cleared the edge of the end cap NOTE Reverse roll screen end caps have additional channels should the idler engage one of these channels use a screw driver to depress the idler and shift into the correct b...

Страница 19: ... models note that the idler bearing is positioned on a spring loaded plate that moves up and down To level this model set the plate to the appropriate position and tighten using the hole at the bottom of the end cap SERVICING SOLO 3 375 TUBE INSTALLATION ...

Страница 20: ...Servicing Tube Installation 4 Reconnect power and the safety spacer with needle nose pliers as seen below SERVICING SOLO 3 375 TUBE INSTALLATION Wirefree Motor 24v DC Motor Reconnect Power Safety spacer x1 ...

Страница 21: ...age with the locking screws NOTE The locking screws will click once they have engaged and the cassette face will align with the end cap 6 Tighten the locking screws until snug closing any gap between the end cap and the cassette locking the cover in place 7 To reinstall the screen refer to page 6 INSTALLATION SERVICING SOLO 3 375 TUBE INSTALLATION Servicing Tube Installation Locking Screws end cap...

Страница 22: ...he screen will jog up and down once to signal that the motor is now awake b In case the charger does not wake up the screen use a thin tool to briefly press the motor button through the small hole just in front of charging port The screen will jog once to indicate it is awake For Wireless Power Before storing servicing or transporting deactivate the motor by putting it in sleep mode to ensure the ...

Страница 23: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 NOTES ...

Страница 24: ...Screen Innovations 9715 B Burnet Rd Suite 400 Austin TX 78758 512 832 6939 www screeninnovations com 4000XX Ι v 1 0 Ι 13 April 2022 ...

Отзывы: