Page 35 of 36
P/N 595225-01 Rev C 4/12
WARNING
DO NOT APPLY ANY MARKINGS OR
LABELS THAT DAMAGE OR INTERFERE
WITH THE OPERATION OF THE EQUIPMENT.
ANY USER APPLIED MARKINGS THAT
INTERFERE WITH THE OPERATION OF
THE EQUIPMENT MAY CAUSE A FAILURE
OF THE EQUIPMENT AND MAY RESULT IN
SERIOUS INJURY OR DEATH.
WARNING
APPLYING ANY MARKINGS OR LABELS
T H AT D A M A G E O R O B S C U R E T H E
EXISTING LABELING MAY INTERFERE
WITH PROPER IDENTIFICATION OF
ASSEMBLIES. IMPROPER IDENTIFICATION
OF ASSEMBLIES MAY RESULT IN ERRORS
I N M A I N T E N A N C E O R O P E R AT I O N
CAUSING FAILURE OF THE EQUIPMENT
WHICH MAY RESULT IN SERIOUS INJURY
OR DEATH.
EQUIPMENT MARKINGS
Do not alter or cover over any labels on the SCOTT RIT-PAK III portable air
supply or air supply cylinder and valve assembly. If user applied identification
markings are added to the SCOTT RIT-PAK III portable air supply or air supply
cylinder and valve assembly, do not obscure any labels supplied on the SCOTT
RIT-PAK III portable air supply or air supply cylinder and valve assembly. Any user
applied markings must be applied in a manner that will not weaken or damage
any components of the SCOTT RIT-PAK III portable air supply or the air supply
cylinder and valve assembly, will not interfere with the proper function of these
assemblies, and will not add flammable materials to these assemblies.
TECHNICAL SPECIFICATIONS
The Pressure Reducer Assembly that is provided with the SCOTT RIT-PAK III
portable air supply is equipped with a relief valve. If air is heard or felt coming
from the relief valve, DO NOT USE THE ASSEMBLY. Remove the equipment from
service and tag for repair by authorized personnel.
A properly functioning Reducer Assembly connected to a fully charged cylinder
(appropriate for the operating pressure of the unit) will have output pressure of
approximately 70 psig to 100 psig with no flow and a minimum outlet pressure
of 55 psig with a flow of approximately 400 liters per minute.
PERIODIC TESTING
SCOTT recommends that the SCOTT RIT-PAK III portable air supply be checked,
both visually and functionally, by a SCOTT Authorized Service Center using SCOTT
Authorized Test Equipment at least every two years. However, heavy use may
require more frequent testing. This recommendation is in addition to all other
cleaning and maintenance procedures.