012681 Promask black 
012670 Promask S (small) black 
012882 Promask SIL yellow 

 

Promask

2

 

+ 2 x filter Pro

2

 

 

 

012890 Promask

2

 SIL grey 

 

 

The Promask has been designed to conform with EN 136/12942 (Europe) and AS/NZS 1716:2003 
(Australia/NZ). EC certified by BGIA (Berufsgenossenschaftliches Institut für Arbeitssicherheit), DE-53754 
Sankt Augustin, Germany, ID: 0121. Licence 0858 by SAI Global, Australia. 

 

1. General 

The Promask is designed to protect the respiratory system and face against hazardous gases and 
particles. 
The filter is selected according to the type of hazard present.

 

 

Promask 

o

 

Use as 

filter mask

 together with a Pro2000 filter (gas, particle or combined filters). The filters are 

thread filters conforming to the European standard EN 148-1. 

o

 

Use 

with a blower device

, with the filters fitted to the blower device. 

o

 

Material: Mask made of butyl-EPDM (Procomp) or silicone. Inner mask made of TPE or silicone. 

 

Promask

2

 

o

 

Use as 

filter mask

 together with Pro

2

 filters (2 pcs, bayonet connection). 

o

 

Material silicone. 

 

2. Limitations of use

 

2.1

 

The filtering device must not be used if the environment and contamination is unknown. In case of 
doubt, isolating respirators (air supply) which function independently of the atmosphere must be 
used. 

2.2

 

The filtering device must not be used in confined spaces (e.g. cisterns, tanks) because of the risk of 
oxygen deficiency or presence of heavy oxygen-displacing gases (e.g. carbon dioxide). 

2.3

 

The filtering device may be used only if the oxygen content of the air is 18

–23 vol.%. 

2.4

 

Gas filters do not protect against particles. Similarly, particle filters do not provide protection against 
gases or vapours. In case of doubt, use combined filters. 

2.5

 

Normal filtering devices do not protect against certain gases such as CO (carbon monoxide), CO

2

 

(carbon dioxide) and N

2

 (nitrogen). 

2.6

 

Particle filters are only allowed for single use if they are applied against radioactive agents or micro-
organisms (virus, bacteria, fungi and spores). 

2.7

 

It is likely that adequate protection cannot be guaranteed 

if the user’s beard, hair, spectacle frames 

or clothing intrude into the faceseal. With the Promask one can use special spectacles (see 012790 
spectacle frame). 

2.8

 

When a breathing protector is used in explosive atmospheres, please follow the instructions given 
for such areas. 

2.9

 

Gas filters shall be replaced when the user begins to sense odour, taste or irritation. Filters used 
against detrimental gases that do not display any significant indications, require special regulations 
for the duration of use and correct usage. 
Particle filters must be replaced at the latest when breathing resistance becomes too high. 

2.10 

The weight of filter used with a full face mask shall not exceed 500 g.  
The Promask is used with one filter only (the other opening on the mask is blocked by the 
manufacturer). 
The Promask

2

 is used with Pro

2

 filters. Always use two filters of the same type and class, always 

replace both filters at the same time. 

With a blower device 

2.11

 

The blower must be running 

while using the respirator. If the blower turns off by accident, the 

device ceases to function as a respirator, and carbon dioxide levels may instantly rise. This is 
considered an exceptional situation. 

2.12

  At a very intense working pace, the pressure in the facepiece can change into negative pressure at 

peak inhalation. 

2.13

  Protection levels may be reduced if wind speed exceeds 2 m/s. 

2.14

  Filters must not be fitted directly to the breathing hose. 

Содержание Promask

Страница 1: ...Instructions for Use ENGLISH 009751 J 01 2010 Promask Promask2 ...

Страница 2: ...2 Promask thread connection EN 148 1 Promask 2 bayonet connection 1 2 3 6b 7b 4 5 6a 7a 7c 8 9 10 aligning mark 11 ...

Страница 3: ...te Visor PM HC hard coated 6a 6b 012689 Valve seat set PM including 1 x Inhalation valve seat 2 x Inner mask valve seat 7a 7b 7c 012690 Disc set PM including 1 x Inhalation valve disc 2 x Inner mask valve disc 1 x Exhalation valve disc 8 012687 Speech diaphragm 9 012688 Exhalation valve cover PM 10 012794 Speech channel cover PM 11 Faceseal Accessories 012698 Visorguard PM 10 pcs 012790 Spectacle ...

Страница 4: ...4 4 1 4 2 4 3 4 4 4 5 4 6 4 7 Promask Promask 2 5 2 Fig A Fig B ...

Страница 5: ...5 Fig C 5 3 Fig D Fig E Fig F 5 4 Fig G Fig H Fig J Inner mask disc Fig X ...

Страница 6: ...6 5 5 Fig K Fig L Fig M 5 6 Fig N Fig O Fig P Fig Q 5 7 Fig R Fig S Fig T Speech channel cover Fig U Fig V ...

Страница 7: ...3 R P3 P R WARRANTY The products manufactured at our factories in Skelmersdale and Vaasa carry a warranty of 12 months unless stated otherwise for parts labour and return to site The warranty period runs from the date of purchase by the end user These products are warranted to be free from defects in materials and workmanship at the time of delivery Scott will be under no liability for any defect ...

Страница 8: ...003 week 9 in the head harness rubber year quarter of year 2001 January March Symbolit 10 ºC 50 ºC 75 See Instructions for Use Recommended storage conditions temperature and humidity Promask2 Twin filter use 2 filters same type class BGIA DE 53754 Sankt Augustin Australia Russia Germany 01 ...

Страница 9: ...9 Spark guard replaces exhalation valve cover Spark guard covers speech channel Recommended to use in dirty circumstances and in welding 1 2 ...

Страница 10: ... not provide protection against gases or vapours In case of doubt use combined filters 2 5 Normal filtering devices do not protect against certain gases such as CO carbon monoxide CO2 carbon dioxide and N2 nitrogen 2 6 Particle filters are only allowed for single use if they are applied against radioactive agents or micro organisms virus bacteria fungi and spores 2 7 It is likely that adequate pro...

Страница 11: ...d full face mask with gas filter TM3 gas filter class 1 2 or 3 40 500 For devices with combined filter apply the relevant limitations of gas and particle filters Device with combined filter The specified multiples of threshold value for the gas or particle filters are given separately but in all cases the lowest value applies Provided that the maximum permissible detrimental gas concentration for ...

Страница 12: ...e is no slippage 4 7 Check tightness of the mask two alternative methods Cover the exhalation opening of the mask with your hand Exhale gently to create overpressure There must be no leakage between the face and the faceseal Cover the filter openings with your hand Inhale to make the mask press onto your face If you fail to get a tight fit potential leakage adjust the head harness and filter or us...

Страница 13: ... must be free to move The valve discs of the inner mask are replaced similarly Make sure that the rubber edge of the inner mask comes in the valve seat groove 5 5 Replacing the speech diaphragm Remove the inner mask from around the speech diaphragm Fig K Press the clip to remove the speech diaphragm Fig L M To make assembly easier moisten the O ring with water Press the speech diaphragm into place...

Страница 14: ...test see Table After use an opened filter must be sealed tightly if it is to be reused but it must be replaced within 6 months at the latest 5 11 Disposal Masks without filters are coarse waste A very contaminated mask as well as used filters are special refuse and shall be disposed of according to the filtered substances gases or particles 5 12 Australia and New Zealand For complete national requ...

Отзывы: