Page 40 of 44
P/N 595236-01 Rev. B 10/11
WARNING
BATTERIES MUST ONLY BE CHANGED IN AN
AREA KNOWN TO BE NONFLAMMABLE.
CHANGING THE BATTERIES IN A FLAMMA-
BLE ATMOSPHERE MAY CAUSE AN IGNI-
TION WHICH COULD RESULT IN SERIOUS
INJURY OR DEATH.
FIGURE 25
FIGURE 24
RESPIRATORS WITH HEADS-UP DISPLAY ONLY
AIR-PAK respirators equipped with a Heads-Up Display but
NO
PASS
device, require two (2) AA batteries in the remote gauge console for op-
eration. The batteries should be replaced only by a trained maintenance
technician in a clean area known to be nonflammable.
Replace batteries as follows:
3. Slide the two batteries out of the battery compartment.
4. To maintain Intrinsic Safety, replace batteries only with a pair of the
following 1.5 volt AA batteries:
–
Eveready
3
Energizer Alkaline EN91
–
Eveready Energizer Alkaline E91.
–
Duracell
4
Alkaline MN1500
–
Duracell Alkaline MX1500
–
Duracell Alkaline PC1500
5. The battery caps must be installed so that they are water tight after
replacement. Clean the inside edge of each battery compartment and
seal around the outside of each cover by wiping with a clean damp
cloth to remove any dirt or foreign matter which might prevent a proper
seal. Check cover gaskets for tears or cuts. If damage is found, remove
respirator from service and tag for repair by authorized personnel.
6. When covers are placed in position and the batteries are properly
installed, all lights in the HEADS-UP DISPLAY will light for approxi-
mately twenty (20) seconds to verify operation.
7. Thread the battery covers in until the edge of the battery cover is
touching the face of the battery compartment. Tighten each screw
HAND TIGHT only. DO NOT OVERTIGHTEN. Perform the REGU-
LAR OPERATIONAL INSPECTION to verify proper operation of the
HEADS-UP DISPLAY.
WARNING
IF A RESPIRATOR INCORPORATING THE
HEADS-UP DISPLAY ONLY IS USED IN AN
EXPLOSIVE OR FLAMMABLE ATMOSPHERE,
REGULARLY INSPECT THE RESPIRATOR,
INCLUDING THE HEADS-UP DISPLAY, AS
DESCRIBED IN THIS INSTRUCTION AND
CORRECT ANY DAMAGE FOUND. DO NOT
SUBSTITUTE ANY PARTS OR COMPONENTS.
USE ONLY THE BATTERIES AS SPECIFIED
IN THIS INSTRUCTION. THE FAILURE TO
CORRECT ANY DAMAGE, THE INSTALLA-
TION OF INCORRECT BATTERIES, OR THE
SUBSTITUTION OF ANY OTHER COMPO-
NENTS MAY IMPAIR THE INTRINSIC SAFETY
OF THE UNIT AND MAY LEAD TO A FIRE OR
AN EXPLOSION WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
1. Locate the remote gauge con-
sole.
2. Using a Phillips driver, remove
both battery caps holding the
battery cover. See FIGURE
24.
Do not mix batteries.
Be
sure batteries are properly
oriented in battery compart-
ment with the "+" end and the
"–" end of each as shown in
FIGURE 25.
3
Energizer is a registered trademark of Eveready Battery Company, Inc., St Louis, MO.
4
Duracell is a registered trademark of The Procter & Gamble Company, Cincinnati, OH.
REMOVE
BOTH CAPS
"–" END OUT
"+" END OUT
WARNING
TO REDUCE THE RISK OF EXPLOSION
USE BATTERIES ONLY FROM THE LIST PRO-
VIDED, DO NOT MIX OLD BATTERIES WITH
UNUSED BATTERIES, AND DO NOT MIX
BATTERIES FROM DIFFERENT MANUFAC-
TURERS. UNAUTHORIZED SUBSTITUTION
OF COMPONENTS MAY IMPAIR INTRIN-
SIC SAFETY AND CAUSE AN EXPLOSION
WHICH COULD LEAD TO SERIOUS INJURY
OR DEATH.
WARNING
BATTERIES ARE REQUIRED FOR PROPER
OPERATION OF THIS EQUIPMENT. FAILURE
TO INSTALL BATTERIES AND TO PERFORM
A REGULAR OPERATIONAL INSPECTION
MAY RESULT IN A MALFUNCTION OF THE
EQUIPMENT WHICH COULD RESULT IN SE-
RIOUS INJURY OR DEATH.
BATTERY REPLACEMENT
WHen the optional Heads-up Display or PASS device are installed, batter-
ies are required for the proper operation of the equipment. Instructions for
battery replacement on optional AIR-PAK respirator features are contained
in this instruction. Certain accessories and features require batteries for
operation. Refer to the user instructions provided with any approved
communications device for details of operation and maintenance. Always
verify that this equipment and all accessories used with it have fresh
batteries before use. Refer to the Operation and Maintenance instructions
provided with any other accessories for details of battery replacement.