Stationary Air Compressor System Operating Instructions
3 - Starting and Operating
20
X4 Control Panel
The X4 Controller control panel may be located on a
separate wall-mounted module or on the breathing air
cylinder charging station. The X4 control panel contains
controls for operating the compressor system.
Follow the directions on the X4 Controller display
screens. You will be instructed to either press one of the
buttons on the keypad (START, OPERATE, PURGE, etc.)
or one of the Function buttons directly below a selection
on the display (F1, F2, or F3).
Before operating the Stationary Air Compressor breath-
ing air system, the operator must be familiar with the
location and function of all controls and gauges.
During operation, the X4 Controller will display service
notices regarding required service activities such as com
-
pressor service or replacement of the Purifying Filters.
The operator is responsible for notifying the
System Ad
-
ministrator
of any messages or alerts regarding service
or maintenance requirements.
Training is required before use of this equipment.
Improper use of this equipment may result in serious
injury or death. Improper use includes, but is not
limited to, use without adequate training, disregard of
the warnings and instructions contained herein and
failure to inspect and maintain this equipment.
Operation of the Compressor System
An electric motor serves as the primary source of power
for the compressor system.
The operator must never leave the Stationary Com-
pressor Breathing Air System unattended while the
compressor system is operating or in use.
Hearing protection may be required when using the Sta
-
tionary Air Compressor system for extended periods of
time. Refer to the personal safety guidelines or require
-
ments of your organization.
Hearing protection may be required when using
the Stationary Air Compressor system for extended
periods of time. Refer to the personal safety
guidelines or requirements of your organization.
Exposure to high sound levels may cause temporary
or permanent hearing loss in some individuals.
Verify the correct compressor rotation before
operation. Rotation should be
counterclockwise
when facing the compressor fan. See the arrows on
the compressor belt guard. If the rotation is incorrect,
DO NOT use the power source until the phasing has
been modified by a certified electrical technician.
After modification, recheck the rotation.
On compressor systems with 3-phase power supplies,
verify the correct compressor rotation before operation
on initial start-up after installation or after any service that
involves the wiring of the power source to the compressor
system. Rotation should be
counterclockwise
when
facing the compressor fan. See the arrows on the
compressor belt guard.
Compressor Rotation
NEVER leave the Stationary Air Compressor system
unattended while the compressor is in use. A
SCOTT trained and certified operator must monitor
the system gauges at all times and take immediate
action to guard against equipment failure. This
equipment is intended for providing breathable air to
save lives. Failure to monitor the system may lead
to permanent equipment damage, serious personal
injury or death.
Содержание HUSH
Страница 1: ...Stationary Air Compressor Systems Operating Instructions HUSH Air Compressor Simple Air Compressor ...
Страница 2: ......
Страница 21: ...3 Starting and Operating Stationary Air Compressor System Operating Instructions 19 NOTES ...
Страница 34: ...Stationary Air Compressor System Operating Instructions 4 Operator Maintenance 32 NOTES ...
Страница 38: ...Stationary Air Compressor System Operating Instructions 5 Additional Features 36 NOTES ...
Страница 45: ...43 Maintenance Record ...
Страница 46: ...44 NOTES ...
Страница 47: ......