Scotsman UF424 Скачать руководство пользователя страница 2

UF424 / UN324 Installation and User Manual

August 2017

9

Bin

1.  Use the same cleaning mixture to thor-

oughly clean bin surfaces.

2.  Rinse with clean water.

3.  Use sanitizer mix on all bin surface areas 

and areas that may contact the ice.

4.  Rinse with clean water.

Filters and Air Cooled Condenser

The air filter located on the lower front grill will 

capture airborne dust during operation.  As the 

dirt builds up, it begins to restrict air flow and 

causes the refrigeration system to work less effi

-

ciently.  Clean the air filter regularly.  

1. 

Remove the filter by sliding it to the right 

until it is clear of the ice machine.

2. 

Remove dust and dirt by washing the filter 

in a utility sink.

3. 

Reinstall filter in the ice machine.  

Condenser

The condenser fins require semi annual cleaning. 

Use caution to prevent damage to the condenser 

fins.

1.  Lightly brush dust from the condenser.

2.  Use a vacuum to thoroughly clean the 

condenser.

Отзывы: