Maintenance and Cleaning

There are 4 areas of maintenance

1.  Ice making system

2.  Photo eye ice level control system 

3.  Bin

4. 

Air cooled condenser and filters

Ice making System:

Remove Scale

1.  Remove front panel. 

2.  Turn the machine off by pressing the on / 

off button.

3.  Empty the ice from the storage bin

4.  Remove the inner panel using the 4 thumb 

screws. 

5.  Remove the top cover from the reservoir.

6.  Shut water supply off at the reservoir by 

turning the knob counterclockwise.

7.  Locate the evaporator drain in the ice 

machine compartment. Unplug it and drain 

the evaporator.

8.  Replug the drain.

9. 

Mix a solution of 1.5qt/1.4L of warm water 

(90

0

F/32

0

C to 110

0

F/43

0

C) and 4 ounces 

of Scotsman Clear 1 Ice Machine Scale 

Remover.

10. Pour the cleaning solution into the reser-

voir until it is full (a squirt bottle may be 

necessary to fill reservoir with cleaning 

solution).

11. Push the clean button.  the machine will 

operate the auger motor for approximately 

20 minutes.  Then it will start making ice 

with the cleaning solution.

12. Add remaining cleaning solution to the 

reservoir as ice is being made for the next 

20 minutes. After the full 40 minutes (steps 

11 & 12) the unit turn off.

13. Drain the solution from the reservoir by 

removing the plug.  Once drained, replace 

the plug.

14. Pour clean water into the bin to melt any 

ice produced during the cleaning cycle.  

15. Mix a solution of 4oz/118ml of Scotsman 

Clear 1 ice machine scale remover and 

16oz/473ml of potable water.  Use this 

scale remover solution for the water reser-

voir cover, ice discharge chutes, the stor-

age bin and the inner front cover.

Sanitize Water System

16. Create a solution of sanitizer.  Mix 

4oz/118ml of NuCalgon IMS III and 

2.5gal/9.5L of (90

0

F/32

0

C to 110

0

F/43

0

C

 

)  

potable water to create a 200 ppm solu-

tion. 

17. Pour the sanitizing solution into the reser-

voir until it is full and wait 2 minutes.

18. Turn on the water supply and press the 

ON /Off button to turn the ice machine on

19. Operate the machine for at least 15 min-

utes.

20. Drain the solution from the system by pull-

ing the reservoir plug from the drain hose. 

Return plug when drained.

Photo Eye ice level control

1.  Mix solution of 4 ounces of Clear 1 Ice 

Machine Scale Remover and 1.5qt/1.4L of 

90

0

F/32

0

C to 110

0

F/43

0

C water.

2.  Remove sensors from inner cover by re-

moving the white c-clip .

3.  Use cotton swab and cleaning solution to 

thoroughly clean photo sensors.

4.  Rinse sensors with clean water. 

5.  Reinstall sensors in inner panel.

Ice machine cleaner contains 

acids.  Acids can cause burns.  

If concentrated cleaner comes 

in contact with skin, flush with 

water.  If swallowed, do NOT  

induce vomiting.  Give large 

amounts of water or milk.  Call 

physician immediately.  Keep 

out of the reach of children.