
Removal and Replacement: Purge Valve
Removal:
1. Unplug unit.
2. Open bin door, remove hood fasteners and pull
hood from ice machine.
3. Remove one screw and pump shield.
4. Loosen 2 screws (1/4" hex head) holding pump
to bracket.
5. Disconnect discharge hose from pump, water
distributor and valve.
6. Pull pump up and out of the machine. Retain for
re-installation.
7. Remove curtain, set aside for re-installation.
8. Shut water off.
9. Loosen float valve retaining nut, slide float valve
to the right and allow to hang by the incoming
water line.
10. Remove plug from under reservoir and drain
the reservoir.
11. Unclip curtain sensor.
12. Remove reservoir support fastener from left
end of reservoir.
13. Remove lower pump bracket bolt, and loosen
upper pump bracket bolt.
14. Remove pump bracket and set aside; lower
reservoir into bin.
15. Locate electrical power plug to purge valve
coil, remove plug.
Curtain Sensor
Pump
Bracket
Bolts
Plug
Electrical shock hazard.
Electrical shock can
cause personal injury.
Disconnect power before
beginning to service
components.
SCE170
October 1998
Page 26