background image

SERVICE DIAGNOSIS: Condition - No Ice Being Produced

STATUS: 

NOTHING OPERATES

H. Check: The gear motor, the motor must turn at full speed or the compressor contactor will not
pull in. If the motor will not turn fast enough, check the auger and evaporator for scale build up. 
If no power to the motor:
Check: The indicator lights on the circuit board, the bin empty light should be ON, the no water
light should be OFF .

1. If the  bin empty and no water lights are off, check the  transformer

a. Transformer “load” side should have 12 to 15 volts.  If not, check the “line” side. The line

 

side should have 115 volts.  If the line side has the correct voltage and the 
load side does not, replace the transformer.

2. If the transformer is good, and the bin empty light is OFF, check the ice level sensors.

a. Remove sensors by sliding them sideways out of the ice chute.  Visually inspect them, 
clean if needed.
b. Look through the ice chute “eye” hole for something blocking the ice chute.
c. If the unit still does not run, replace the ice level sensors.
d. If the bin empty light is still OFF, check the circuit board.

See the instructions at the end of the manual. If the machine operates with the 
testor, and not by itself, the ice level sensors should be replaced.

3. If the transformer is fine, and the “no water” light is ON, check the water level sensor.

a. Check the water level in the reservoir, restore if low. If the water level is ok:
b. Remove the water level sensor from the reservoir and clean the tip if dirty.
CAUTION:  THE TIP IS MADE OF GLASS
c.  Replace the water level sensor.  If the no water light is still on, check that the 
"water sen" plug is firmly plugged into the circuit board. 
d.  If the no water light is still on, check the circuit board:

1. Unplug the “water sen” connector from the circuit board.
2. Plug “water sen” connector from the Scotsman Electronic Control tester into 
the  circuit board.

a. Move the water switch on the tester to “no water” and the no water light 
on the circuit board should go on.  If not, replace the board.
b. Move the water switch to the “water” position, the no water light should 
go off and after 15 seconds, the machine should start, if not, 
replace the circuit board.
If the machine works with the tester, and not by itself, 
replace the water level sensor.

MORE INFORMATION ON THE TESTER CAN BE FOUND AT THE END OF THE MANUAL.

Check the gearmotor relay on the circuit board. 
If the bin empty light is on, and the water level light is off, there should be power (after 15
seconds) at the com. terminal of the gearmotor relay, if not, replace the circuit board.

NM650

January, 1991

Page 21

Содержание NM650

Страница 1: ...ice and water level a thermostatic expansion valve and R 502 as the refrigerant TABLE OF CONTENTS Installation For the Installer Specifications 2 Location 4 Two units on one bin 5 For the Plumber 6 Fo...

Страница 2: ...umber NM650AE 1A NM650WE 1A NM650AE 32A NM650WE 32A Diminsions w o bin H X W X D 27 x 21 x 24 same same same Basic Electrical 115 60 1 same 208 230 60 1 same Ice Type NUGGET same same same Condenser T...

Страница 3: ...es the water used to make ice should be filtered or treated depending upon the water There is no one type of water filter that is effective in all situations That is why a water test is important Note...

Страница 4: ...the leg levelers all the way in preparation for leveling later Return the bin to the upright position remove paper covering the bin gasket Note Do not push bin into position but lift it there Pushing...

Страница 5: ...FOR THE INSTALLER Location TWO UNITS ON ONE BIN ALLOW ROOM FOR AIR CIRCULATION AND SERVICE ACCESS DO NOT STACK ANYTHING IN FRONT OF THE MACHINE S NM650 January 1991 Page 5...

Страница 6: ...cabinet The water pressure to all lines must always be above 20 psig and below 120 psig Drains Air Cooled Models There is one 3 4 FPT drain at the back of the cabinet the drain line is of the gravity...

Страница 7: ...machine requires a solid chassis to earth ground wire The ice maker should be connected to its own electrical circuit so it would be individually fused Voltage variation must remain within design limi...

Страница 8: ...late requirements 3 Have all the plumbing connections been made and checked for leaks 4 Has the machine and bin been leveled 5 Is there a minimum of 6 clearance at the back of the machine for proper s...

Страница 9: ...valve will open and warm water will be discharged into the drain 5 The unit should soon be making ice if desired the low side pressure can be checked it should be 30 psig or 4 psig The suction line te...

Страница 10: ...make ice out of Will shut the machine off it there is no water Ice Discharge Chute Directs the ice produced by the evaporator into the storage bin Ice Level Sensor An electronic eye it senses the pre...

Страница 11: ...of ice when the unit turns off and for the compressor Early models before late 1990 production had a reset switch is mounted on the circuit board Transformer Supplies low voltage to the circuit board...

Страница 12: ...two seal faces meet Ice Sweep A plastic cap with fingers It revolves with the auger to sweep the ice into the ice chute Breaker Divider Where the ice is compressed and much of the extra water is sque...

Страница 13: ...clearing out ice in the evaporator and then The auger motor relay opens and the auger motor stops If the ice level sensor is clear bin empty for more than 15 seconds the machine will start up again A...

Страница 14: ...e bottom of the evaporator Reservoir overflow or evaporator condensation is routed to the drain Water cooled models have a separate water circuit for the cooling water it enters the fitting at the rea...

Страница 15: ...upon the temperature of the evaporator warmer evaporators get more refrigerant and colder evaporators get less At the evaporator the refrigerant enters an area of relatively low pressure where it can...

Страница 16: ...sphoric and Hydroxyacetic acids These compounds are corrosive and may cause burns If swallowed DO NOT induce vomiting Give large amounts of water or milk Call Physician immediately In case of external...

Страница 17: ...buildup 3 The bearing in the breaker should also be checked at least two times per year A Check the bearing by removing the ice chute cover unscrewing the ice sweep removing the water shed using a spa...

Страница 18: ...a wire brush A Disconnect electrical power and remove the filter The filter may be cleaned or replaced B Clean the condenser the condenser may appear to be clean on the surface but it can still be clo...

Страница 19: ...1 To remove the auger remove the front and top panels 2 Remove 3 hex studs holding ice chute cover to ice chute and remove cover 3 Unscrew and remove ice sweep 4 Loosen band clamp under ice chute and...

Страница 20: ...r evacuate and weigh in the nameplate charge E Check the high pressure cut out if closed go to F if open check 1 The pressure control opens at 400 psig Check the high side pressure reset the control a...

Страница 21: ...elf the ice level sensors should be replaced 3 If the transformer is fine and the no water light is ON check the water level sensor a Check the water level in the reservoir restore if low If the water...

Страница 22: ...il is open replace the contactor 3 Check the auger drive motor centrifugal switch If when the drive motor is running contact 4 black wire removed has no power and all of the above switches have been c...

Страница 23: ...ter leaks replace the water seal if found to be leaking 3 Check the low side pressure normal is about 30 psig If low assume a refrigerant leak locate repair and recharge If no leak the TXV may be rest...

Страница 24: ...emaker 8 Reverse to reassemble BIN CONTROLS Ice Level Sensors 1 Disconnect electrical power 2 Remove front panel 3 Remove control box cover 4 Locate ice chute at the base of the chute in front of and...

Страница 25: ...top of auger c Unscrew 4 allen head cap screws holding breaker to evaporator d Lift up and remove breaker bearing assembly from auger evaporator 6 Service the bearing Check for rust rough spots and d...

Страница 26: ...r left hand threads b Unscrew auger stud from top of auger c Unscrew 4 allen head cap screws holding breaker to evaporator d Lift up remove breaker from evaporator e If the auger is stuck use a slide...

Страница 27: ...n against it 3 The part of the water seal that rotates with the auger must also be replaced Remove the old part from the auger and clean the mounting area 4 Place a small bead of food grade silastic s...

Страница 28: ...ated then weigh in the nameplate charge Check for leaks 8 Install auger breaker breaker bearing assembly and ice discharge chute in reverse order of disassembly See To Reassemble Evaporator and Auger...

Страница 29: ...rings They are likely to be fine if the oil is If there is evidence of water in the oil rusty bearings and gears the oil having a creamy white appearance oil level too high carefully inspect the beari...

Страница 30: ...hat the ice level sensors are properly aligned clean and not obstructed use the tester as follows Bin Control Note All testing is done with the electrical power on the master switch on and all reset s...

Страница 31: ...ot replace the circuit board b Move the water switch on the tester to the Water position The No Water light on the board should go OFF If not replace the circuit board If the light does go off replace...

Отзывы: