14. Open the control box door. Locate the blue wires connected together with an
insulted double male quick connect. Disconnect the blue wires at the quick connect.
15. Route the blue wires thru the snap bushing the bottom of the control box and
connect them to the thermostat.
16. Route bin thermostat capillary tube through the space next to the ice chute.
Thermostat Bracket
17. Route thermostat cap tube thru the hole in the top of the separator and down into
the dispenser. Pull all of it thru. See Figure A on next page.
18. Thread the cap tube thru the holes in the bracket as shown in Figure B on the next
page. A horizontal loop of cap tube will be on the ice side of the bracket.
19. Position the ice machine 14.5" from the right edge of the adapter. This will allow the
ice to fall into the dispenser equally to the left and right.
20. Seal the ice machine to the adapter.
Dispenser:
21. Set the agitation for 2 seconds on, 3 hours off.
Reconnect electrical power.
Return all panels and covers to their normal positions and secure with the original
screws.
14.5 in
Ice Machine
ED300