OPERATION: Water
Water enters the machine through the 3/8" male
flare at the rear of the cabinet, splits into two
separate lines, flows to a strainer at each reservoir
and then to each water reservoir which it enters
through the float valve. The water then goes out
the bottom of the reservoir tanks to the bottom of
each evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain.
Water cooled models have a separate water circuit
for the cooling water: it enters the fitting at the rear,
divides and goes to the two water regulating
valves, then through each water cooled
condenser, reconnects into one drain and down
the drain.
EVAPORATOR
DRAIN
WATER
LEVEL
EVAPORATOR
ICE
CHUTE
DRAIN
STRAINER
WATER SCHEMATIC
RESERVOIR
WATER INLET
EVAPORATOR INLET
NME1850 & FME2400
January 1994
Page 14