Installation Limitations:
This ice system is designed to be installed indoors,
in a controlled environment:
Min. Max.
Air Temperature
50
0
F 100
0
F
Water Temperature
40
0
F 100
0
F
Water Pressure
20 psi 80 psi
Voltage
198
253
(Compared to the nameplate)
Operating the machine outside of the limitations is
misuse and can void the warranty.
Water Limitations
An ice machine makes food. The purity of the
water is very important in obtaining pure ice and in
maximizing product life.
General Recommendations:
1. Filter the water used to produce ice (the water
going to the potable water connection). Water
filters vary in ability and function. Install one that
filters out suspended solids to a dimension of 5
microns or smaller. The finer the filter the better,
but finer filters will clog sooner than course ones. It
may be necessary to add a course filter ahead of
the fine filter to prolong filter life.
2. Check with a water treatment specialist for a
water test, and recommendations regarding filters
and treatment.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and CUL
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
NME1254 & FME1504
January 2000
Page 3
FOR THE INSTALLER: Environmental Limitations