FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
The electrical power to the unit is
supplied through the junction box at
the rear of the machine.
Check the nameplate (located on the
back panel) for the voltage
requirements, and for the minimum
circuit ampacity. The machine
requires a solid chassis to earth
ground wire.
The ice maker should be connected to
its own electrical circuit so it would be
individually fused. Voltage variation
must remain within design limitations,
even under starting conditions.
Electrically the remote condenser fan
motor is connected to the icemaker at
the contactor terminals for the
compressor and the fan motor
operates whenever the compressor
operates.
Electrical connections are made at the
junction box at the back of the
icemaker and at the junction box on
the remote condenser.
The remote condenser must be wired
to the icemaker in accordance with
local and national electrical codes with
a minimum of 18 Awg. wire with an
ground bonding wire connected to the
ground screws provided in both the
condenser and machine field wiring
boxes. All outdoor wiring must be in
rainproof conduit.
All external wiring must conform to
national, state, and local electrical
codes. The use of a licensed
electrician is required to perform
the electrical installation.
REMOTE CONDENSER
WATERPROOF
(LIQUID TIGHT)
CONDUIT
ICEMAKER
JUNCTION BOX
POWER
SUPPLY
FM1500R
November, 1988
Page 10