Technical Specifications
Ice Making Section (IMS)
Compressor Package
Condenser
* * ERC condenser fan motor is powered from CP
unit and the ERC’s ampacity is included in CP unit
numbers.
Note: The ERC680, ERC1086 and ERC26810 do
NOT contain a headmaster. The headmaster is in
the CP units.
Note: 75 feet of interconnecting control wire (24
volt) is included with the CP units.
Eclipse
ä
600, 800, 1000
May 2002
Page 3
Model
Voltage
Minimum Circuit
Ampacity
Max Fuse Size Cabinet Size
Weight (lb)
CME686RLS-1A
115/60/1
3
15
22”w x 16.5”d x 28” h* 92
CME810RLS-1A
115/60/1
3
15
same
92
* Height does not include bin control. (add 3”)
Model
Voltage
Contains
Headmaster?
Minimum
Circuit
Ampacity
Max
Fuse
Size
Refrigerant
Charge (R-404A)*
(oz)
Cabinet Size
Weight
(lb)
CP686-32A
208-230/60/1 Yes
9.8
15
232
29 ¾”w x 18”d x 34 ½”h
CP686-3A
208-230/60/3 Yes
6.9
15
232
same
CP886-32A
208-230/60/1 Yes
14.6
15
232
same
180
CP886-3A
208-230/60/3 Yes
10.4
15
232
same
180
CP1086-32A 208-230/60/1 Yes
21.0
25
272
same
180
CP1086-3A
208-230/60/3 Yes
14.0
15
272
same
180
* Includes entire system charge.
Model
Voltage
Contains
Headmaster?
Number
of
Circuits
Minimum
Circuit
Ampacity**
Max
Fuse
Size**
Cabinet Size, with legs
Weight
(lb)
ERC680-32A
208-230/60/1
No
1
1.25
15
29 ¾”w x 28 5/8”d x 38 ½”h
95
ERC1086-32A
208-230/60/1
No
1
1.25
15
same
95
ER2C6810-32
208-230/60/1
No
2
1.9
15