REMOVAL AND REPLACEMENT
Water Distributor Tubes And Manifold Tubes
To remove the water distributor tube and manifold
tube:
1. Remove the front panel.
2. Slide the water distributor tube to the front about
1/8-inch along the top of the evaporator plate, until
the water distributor tube can be unsnapped from
the flexible notch and lifted upward.
3. Unsnap and disconnect water distributor tubes
from the water manifold section. To replace the
water distributor tubes and manifold tubes, reverse
the removal procedure. BE SURE the notches in
the water manifold tubes properly engage the
alignment keys in the tee. BE SURE the water
distributor tube is securely fastened at the notch at
both sides of the evaporator plate. Check identical
attachment for the left water distributor tube and
notch; also, that the distributor/manifold
connections at the top center of each evaporator
plate is snug against the top of the plate.
Cube Size Control
To remove the cube size control:
1. Remove front panel.
2. Remove cover from control box.
3. Trace capillary tube, from the cube size control
to the refrigerant suction line.
4. Remove the coiled capillary tube bulb from the
tube well on the suction line.
5. Remove electrical leads from the cube size
control.
6. Remove screws and pull the capillary tube
through the notch in the back of the control box.
Remove the cube size control. To replace the cube
size control, reverse the removal procedure.
Electrical Shock Hazard.
Electrical shock can
cause personal injury.
Disconnect power
before begining to
service components
DISTRIBUTOR TUBE
NOTCH IN CONTROL
BOX
CUBE SIZE
CONTROL
REMOVAL OF THE
CUBE SIZE CONTROL
CMS1402
September 1993
Page 23