Refrigeration Light
– Is ON without blinking
•
Low discharge temperature OR
•
Maximum length freeze cycle OR
•
Water cooled or remote may have cut out on high
discharge pressure
– Control resets automatically, but the controller may
have timed out, depending upon when in the freeze
cycle the control reset